Merge pull request #474 from xifle/Marlin_v1
Fixed "Cooldown" Selection not reseting bed temp
This commit is contained in:
		@@ -252,6 +252,7 @@ void lcd_preheat_pla()
 | 
			
		||||
    setTargetBed(plaPreheatHPBTemp);
 | 
			
		||||
    fanSpeed = plaPreheatFanSpeed;
 | 
			
		||||
    lcd_return_to_status();
 | 
			
		||||
	setWatch();	// heater sanity check timer
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
void lcd_preheat_abs()
 | 
			
		||||
@@ -262,6 +263,16 @@ void lcd_preheat_abs()
 | 
			
		||||
    setTargetBed(absPreheatHPBTemp);
 | 
			
		||||
    fanSpeed = absPreheatFanSpeed;
 | 
			
		||||
    lcd_return_to_status();
 | 
			
		||||
	setWatch();	// heater sanity check timer
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
static void lcd_cooldown()
 | 
			
		||||
{
 | 
			
		||||
	setTargetHotend0(0);
 | 
			
		||||
	setTargetHotend1(0);
 | 
			
		||||
	setTargetHotend2(0);
 | 
			
		||||
	setTargetBed(0);
 | 
			
		||||
	lcd_return_to_status();
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
static void lcd_tune_menu()
 | 
			
		||||
@@ -299,7 +310,7 @@ static void lcd_prepare_menu()
 | 
			
		||||
    //MENU_ITEM(gcode, MSG_SET_ORIGIN, PSTR("G92 X0 Y0 Z0"));
 | 
			
		||||
    MENU_ITEM(function, MSG_PREHEAT_PLA, lcd_preheat_pla);
 | 
			
		||||
    MENU_ITEM(function, MSG_PREHEAT_ABS, lcd_preheat_abs);
 | 
			
		||||
    MENU_ITEM(gcode, MSG_COOLDOWN, PSTR("M104 S0\nM140 S0"));
 | 
			
		||||
    MENU_ITEM(function, MSG_COOLDOWN, lcd_cooldown);
 | 
			
		||||
    MENU_ITEM(submenu, MSG_MOVE_AXIS, lcd_move_menu);
 | 
			
		||||
    END_MENU();
 | 
			
		||||
}
 | 
			
		||||
 
 | 
			
		||||