Fixed "Cooldown" Selection not reseting bed temp
- enquecommand with multiple lines "\n" doesn't work -> M140 S0 didn't get processed. So I wrote a new func for the cooldown which uses setTargetHotend. In addition this does return to status page after selection. - Added setWatch() to preheat-functions (Temperatur sanity check would never have worked when preheating from the lcd panel)
This commit is contained in:
parent
90664d20a4
commit
29bb8d7d4f
@ -252,6 +252,7 @@ void lcd_preheat_pla()
|
||||
setTargetBed(plaPreheatHPBTemp);
|
||||
fanSpeed = plaPreheatFanSpeed;
|
||||
lcd_return_to_status();
|
||||
setWatch(); // heater sanity check timer
|
||||
}
|
||||
|
||||
void lcd_preheat_abs()
|
||||
@ -262,6 +263,16 @@ void lcd_preheat_abs()
|
||||
setTargetBed(absPreheatHPBTemp);
|
||||
fanSpeed = absPreheatFanSpeed;
|
||||
lcd_return_to_status();
|
||||
setWatch(); // heater sanity check timer
|
||||
}
|
||||
|
||||
static void lcd_cooldown()
|
||||
{
|
||||
setTargetHotend0(0);
|
||||
setTargetHotend1(0);
|
||||
setTargetHotend2(0);
|
||||
setTargetBed(0);
|
||||
lcd_return_to_status();
|
||||
}
|
||||
|
||||
static void lcd_tune_menu()
|
||||
@ -299,7 +310,7 @@ static void lcd_prepare_menu()
|
||||
//MENU_ITEM(gcode, MSG_SET_ORIGIN, PSTR("G92 X0 Y0 Z0"));
|
||||
MENU_ITEM(function, MSG_PREHEAT_PLA, lcd_preheat_pla);
|
||||
MENU_ITEM(function, MSG_PREHEAT_ABS, lcd_preheat_abs);
|
||||
MENU_ITEM(gcode, MSG_COOLDOWN, PSTR("M104 S0\nM140 S0"));
|
||||
MENU_ITEM(function, MSG_COOLDOWN, lcd_cooldown);
|
||||
MENU_ITEM(submenu, MSG_MOVE_AXIS, lcd_move_menu);
|
||||
END_MENU();
|
||||
}
|
||||
|