Commit Graph

191 Commits

Author SHA1 Message Date
esenapaj
92c03a44a9 Fix the PR #4899 (ABL: Enable by type. Bilinear for all.) etc.
About Configuration.h:
・Fix the PR #4899 (ABL: Enable by type. Bilinear for all.)
Remove Duplicated contents

・Fix the PR #4305 (Custom boot screen feature improvement)
Revert from "during boot" to "during bootup" in all the example
Configuration.h

・Fix the PR #4207 (Clean up, simplify and generalize the Allen-key-probe
code.)
Resolve and relocate the duplicated definitions in Z_PROBE_ALLEN_KEY
section

・Follow-up the PR #4805 (Additional documentation of Configuration.h)
Add forgotten changes to all the example Configuration.h

Adjust spacing

About Configuration_adv.h:
Add missing description of SLOWDOWN for DELTA

Adjust spacing
2016-09-28 14:14:04 -05:00
Scott Lahteine
ea0dbee3c9 Enable ABL by type, support bilinear on cartesian 2016-09-25 23:35:37 -05:00
Scott Lahteine
01f1028510 Try on "CLEARANCE" for size 2016-09-20 18:29:49 -05:00
Scott Lahteine
0e7d638a7a Revert to Probe Raise rather than Probe Height 2016-09-20 18:29:49 -05:00
Scott Lahteine
e05af606a8 Clean up probe config options 2016-09-19 00:26:16 -05:00
Scott Lahteine
c4dcfa254e Allow override of Z_ENDSTOP_SERVO_NR with BLTOUCH 2016-09-18 22:00:32 -05:00
Scott Lahteine
e5505e3b33 Allow non-square leveling grid 2016-09-18 13:11:20 -05:00
Scott Lahteine
a1812b55f6 Space out array values 2016-09-16 14:41:05 -05:00
Scott Lahteine
d4599fd8ed Comment patches to Configuration.h 2016-09-16 14:41:05 -05:00
Scott Lahteine
723e983073 Default EXTRUDE_MAXLENGTH to 200mm 2016-09-16 14:41:04 -05:00
Scott Lahteine
a6f6ed352b Fix comment on FILAMENT_RUNOUT_SENSOR 2016-09-13 02:14:34 -05:00
Scott Lahteine
aaef7c6b89 Fix a misspelling of minimum 2016-09-02 01:42:38 -05:00
Scott Lahteine
f1201e11c7 Improve the Jerk description 2016-08-29 12:39:21 -05:00
Scott Lahteine
3f038bef00 Heading for movement settings 2016-08-29 02:01:34 -05:00
Scott Lahteine
01d4703429 PREVENT_DANGEROUS_EXTRUDE => PREVENT_COLD_EXTRUSION
Also improve the documentation of this and related options, and set
EXTRUDE_MINTEMP to 170 everywhere.
2016-08-20 23:35:27 -05:00
Scott Lahteine
99b22d5785 Default AUTO_BED_LEVELING_GRID_POINTS to 3 2016-08-19 04:45:32 -05:00
Scott Lahteine
e113740fa3 Specify that Z_PROBE_*_HEIGHT is nozzle-relative 2016-08-07 17:54:17 -07:00
Scott Lahteine
7e2bd9a233 Z_RAISE_PROBE_* => Z_PROBE_*_HEIGHT 2016-08-03 21:18:38 -07:00
esenapaj
657ef8aded Follow-up the PR #4408 (Add support for reprapworld LCD), etc
・Put #define REPRAPWORLD_GRAPHICAL_LCD into all the example
configuration files
・Adjust spacing
2016-07-30 20:32:57 +09:00
Scott Lahteine
9e21b2e51d Merge pull request #4455 from AnHardt/double-bump-feature
double bump probing as a feature
2016-07-29 20:00:10 -07:00
AnHardt
7188ce0ad6 double bump probing as a feature
Why double touch probing is not a good thing.

It's widely believed we can get better __probing__ results when using a double touch when probing.

Let's compare to double touch __homing__.
Or better let's begin with single touch __homing__.
We home to find out out position, so our position is unknown.
To find the endstop we have to move into the direction of the endstop.
The maximum way we have to move is a bit longer than the axis length.
When we arrive at the endstop - when it triggers, the stepper pulses are stopped immediately.
It's a sudden stop. No smooth deacceleration is possible.
Depending on the speed and the moving mass we lose steps here.
Only if we approached slow enough (below jerk speed?) we will not lose steps.

Moving a complete axis length, that slow, takes for ever.
To speed up homing, we now make the first approach faster, get a guess about our position,
back up a bit and make a second slower approach to get a exact result without losing steps.

What we do in double touch probing is the same. But the difference here is:
a. we already know where we are
b. if the first approach is to fast we will lose steps here to.
But this time there is no second approach to set the position to 0. We are measuring only.
The lost steps are permanent until we home the next time.

So if you experienced permanently rising values in M48 you now know why. (Too fast, suddenly stopped, first approach)

What can we do to improve probing?
We can use the information about our current position.
We can make a really fast, but deaccelerated, move to a place we know it is a bit before the trigger point.
And then move the rest of the way really slow.
2016-07-30 03:00:49 +02:00
Scott Lahteine
c31f56a38c Deprecate EXTRUDER_WATTS and BED_WATTS 2016-07-29 17:34:14 -07:00
Scott Lahteine
ea5ac94804 Improved MANUAL_[XYZ]_HOME_POS
No need for `MANUAL_HOME_POSITIONS`. Just set each one as-needed to
override the automatic behavior.
2016-07-28 19:51:48 -07:00
Scott Lahteine
8953e3e984 Allow Z_SAFE_HOMING without a probe 2016-07-27 04:33:56 -07:00
Scott Lahteine
24a1a16e5d Move versioning to MarlinConfig.h 2016-07-26 12:37:14 -07:00
Scott Lahteine
277899c175 Move include _Bootscreen.h where needed 2016-07-26 12:37:13 -07:00
Scott Lahteine
83c4653c71 Include boards and macros ahead of configs 2016-07-26 12:19:50 -07:00
Scott Lahteine
c6226bb0aa Unify config in a single include without nested includes 2016-07-25 23:04:19 -07:00
Scott Lahteine
2d378fac1b No need to include thermistortables.h in Configuration.h 2016-07-25 22:43:50 -07:00
Scott Lahteine
bb9da6ebdd Document DEBUG_LEVELING_FEATURE 2016-07-22 23:37:41 -07:00
Scott Lahteine
194d9521c3 Merge pull request #4356 from thinkyhead/rc_simpler_run_z_probe
Unify run_z_probe
2016-07-19 19:02:39 -07:00
Scott Lahteine
4a6ed5e221 Use HOMING_FEEDRATE_Z for Z_PROBE_SPEED_FAST 2016-07-19 18:42:48 -07:00
AnHardt
09a3cc33e6 Unify run_z_probe
Unify run_z_probe
Add double touch for DELTAs.
Introduce Z_PROBE_SPEED_FAST and Z_PROBE_SPEED_SLOW
  defaulting to homing_feedrate_mm_m[Z_AXIS] and homing_feedrate_mm_m[Z_AXIS]/2
2016-07-19 18:42:48 -07:00
Scott Lahteine
e44b37cdc2 motion section marker below homing speeds 2016-07-19 17:31:58 -07:00
Scott Lahteine
204fd6ec44 Set homing feedrates individually 2016-07-19 17:31:58 -07:00
Scott Lahteine
6abf916575 Reprapworld Keypad move step is 1mm 2016-07-19 16:40:39 -07:00
João Brázio
b869fbc05e Update all config files with the new G12 options 2016-07-19 15:07:03 -07:00
Scott Lahteine
81e01152bb Merge pull request #4336 from thinkyhead/rc_bltouch_sensor
BLTouch probe sensor
2016-07-17 14:06:32 -07:00
Scott Lahteine
1583177ef4 BLTOUCH probe config option 2016-07-17 13:55:38 -07:00
Scott Lahteine
39706f3e57 Endstop invert flags as macros instead of const bool 2016-07-17 13:51:02 -07:00
Scott Lahteine
671634bf11 Fix spacing after section header 2016-07-17 13:35:21 -07:00
Scott Lahteine
22b4cff423 New extruder type configuration options 2016-07-17 00:13:56 -07:00
Scott Lahteine
bf16ae5a70 Merge pull request #4299 from jbrazio/feature/g27-park-nozzle
Implements park nozzle feature
2016-07-16 23:47:12 -07:00
João Brázio
dfa1c45075 Adds a notice to vendors about the SHOW_CUSTOM_BOOTSCREEN directive 2016-07-17 01:15:17 +01:00
João Brázio
9a00108cb6 Adds the WEBSITE_URL as the boot screen line 2 2016-07-16 12:24:37 +01:00
João Brázio
336481ea81 Added G27 configuration options to all configs 2016-07-16 12:07:59 +01:00
João Brázio
68c343a09a Added G12 configuration options to all configs 2016-07-14 00:38:42 +01:00
Scott Lahteine
a8b6b6a128 Merge pull request #4252 from thinkyhead/rc_rename_hpb
Replace PLA/ABS preheating with generic
2016-07-12 20:00:33 -07:00
Scott Lahteine
928ff6487a Greek language pack from @psavva 2016-07-10 18:59:04 -07:00
Scott Lahteine
182c8d7f8f Dyze High Temp Thermistor Support 2016-07-10 17:59:05 -07:00