- Fixed incorrect LCD text string
- Fixed incorrect refresh of filament change screens
- Allow host control via touch UI
- Updates to leveling menu
- Modified ExtUI::isPrinting() to check if the job timer is running
- Added ExtUI method to check whether a host print is paused
* Improvements to FTDI DLCache functionality.
* Better handling of long file names in Touch UI
- Long file names now truncated and shown with ellipsis.
- Increased display cache buffer to allow for longer filenames.
- Visual error message when display cache is exceeded.
- Fix unused variable warning
- Fix for filament runout sound
- Fix for developer menu access
- Fix compilation error when using CALIBRATION_GCODE
- Remove material labels in change filament screen
- Add decimals to status screen Z coordinate
- Add more descriptive message on heater timeout
- Stop print and play error sound if USB drive is removed.
- Allow configuration of version string in touch UI.
- Print a completion message in the bed mesh leveling screen.
- Don't play redundant sound at the start of a print.
- Clicking on percentage in status screen now goes into print speed screen
- Clicking on axis in status screen now goes to nozzle motion screens
- Use default increment of 100 when nozzle is preheated in temp screen, 10 otherwise
- Fixed grayed out change filament button in tune menu
- Eliminated code duplication in tune menu
- Add button for resetting BLTouch to advanced settings menu
- Fix timeout and debugging string
- Fix check for whether `LCD_TIMEOUT_TO_STATUS` is valid
- Fix incorrect debugging message
- Make capitalization of callbacks consistent.
- Allow Touch UI to use hardware SPI on Einsy boards
- Move print stats to About Printer page.
- More generic about screen with GPL license.
- Add missing handler for power loss event
- Less code duplication on status screen and main/advanced menu; more legible
- Reorganize advanced and main menu to add more features
- Hide home Z button when using Z_SAFE_HOMING
- Fix compilation errors when certain features enabled
- Fix missing labels in UI
- Improve color scheme
- Add new preheat menus
- Fix incorrect rendering of Marlin logo on boot
- Add Level X Axis and Auto calibrate buttons
M303 D will now toggle activation of PID_DEBUG output. This allows the debug capability to be built into the firmware, but turned on and off as needed.
The code is slightly more optimized than it used to be and this has caused the setup and hold times on the Formbot T-Rex 2+ machines to be insufficient. This change gives sufficient margin and the LCD Display is clean again.
Something has shifted. The previous timing delays on the Max7219 debug displays is too tight without this correction.
I suspect something has been optimized and roughly 50ns of needed setup and hold time has disappeared.
This corrects the issue and the display results are clean again.
Some of the items in the Tool Offset Adjustment menu (in particular, the Z Offset!!!) were only adjustable with .1mm accuracy.
This is not enough. So the edit menu is switched to float52 to fix the issue.
If the IDEX mode was previously set (via GCode or the LCD Panel) to a duplication mode... It was lost after a G28 due to this redundant setting of 'extruder_duplication_enabled'.
It is very important to the various use cases of IDEX machines that extruder_duplication_enabled is preserved across a G28. The reason is this allows a person to use the LCD Panel to put the machine into a duplication mode, and then send a 'normal' part file to the printer and get two parts out of the process.
Allow LCD Menu to adjust Junction Deviation lower than .01. Some machines currently have a JUNCTION_DEVIATION_MM value as low as .005 mm. In the case of non-Linear-Advance machines... The upper limit is raised to .5 mm.
Probably more thought needs to be given to the Linear Advance case. It maybe it doesn't need a special case and should just use the same bounds as the non-Linear Advance case.
The extra clutter was making the Junction Deviation patch script calculate the wrong value.
(The script wasn't smart enough to see the extra lines were commented out and used the wrong values in the calculation.)
All fixed now with a JUNCTION_DEVIATION_MM calculated at .017
Re-apply the formula .4 * V^2 / Default_Acceleration to work correctly in Raptor configuration.h file.
(The problem is there are multiple XJerk and YJerk values declared based on the step sticks used on the printer.)
This change should provide correct values for all setups.