gralcoandScott Lahteine 908229dbb3 Introduce temp watch protection for the bed
When setting the bed temp via M140/M190 if the thermistor does not read an increase of WATCH_BED_TEMP_INCREASE degrees by WATCH_BED_TEMP_PERIOD seconds then it will throw "Error:Heating failed, system stopped! Heater_ID: bed" and call the kill() function.

Conflicts:
	Marlin/Configuration_adv.h
2016-05-01 13:12:51 -07:00
gralco 840e13f664 Introduce M108 cancel heatup for the hotend and bed
This G-code is asynchronously handled in the get_serial_commands() parser.
2016-04-25 08:33:33 -06:00
gralco 8ec8d59df8 Use #if TEMP_RESIDENCY_TIME > 0 rather than #ifdef TEMP_RESIDENCY_TIME 2016-04-15 11:20:32 -06:00
gralco 69c00aea4c Include bed hysteresis setting in the example configs 2016-04-14 08:03:38 -06:00
gralco 178aeb79c8 Implementation of M190 bed temp hysteresis 2016-04-12 08:56:14 -06:00
gralcoandScott Lahteine c218db136a Fix for M109 and M190 cooldown
Also removes the re-definition of now inside M190's while loop
2016-04-11 17:12:23 -07:00
gralcoandScott Lahteine 907aed57db Fix bug which can cause an infinite M109 loop
Since residency_start_ms is -1 when entering the heatup while loop whilst the hotend temp is close to the target them already then it may not escape.

Hence "Start the TEMP_RESIDENCY_TIME timer when we reach target temp for the first time."
2016-04-08 21:20:23 -07:00