LCD_BED_LEVELING enables a sub-menu for ABL
This commit is contained in:
parent
a90d99c27c
commit
b7e938a9fb
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1084,8 +1084,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1202,8 +1202,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1082,8 +1082,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1052,8 +1052,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1076,8 +1076,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1052,8 +1052,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1063,8 +1063,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1074,8 +1074,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1065,8 +1065,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1083,8 +1083,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1074,8 +1074,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1068,8 +1068,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1068,8 +1068,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1074,8 +1074,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1046,8 +1046,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1046,8 +1046,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1088,8 +1088,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1079,8 +1079,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1080,8 +1080,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1079,8 +1079,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1068,8 +1068,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1075,8 +1075,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1084,8 +1084,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1103,8 +1103,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1063,8 +1063,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1068,8 +1068,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1068,8 +1068,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1113,8 +1113,8 @@ Black rubber belt(MXL), 18 - tooth aluminium pulley : 87.489 step per mm (Huxley
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1062,8 +1062,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1077,8 +1077,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1067,8 +1067,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1095,8 +1095,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1120,8 +1120,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1075,8 +1075,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1094,8 +1094,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1071,8 +1071,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1064,8 +1064,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1215,8 +1215,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1197,8 +1197,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1196,8 +1196,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1210,8 +1210,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1184,8 +1184,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1187,8 +1187,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1187,8 +1187,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1187,8 +1187,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1085,8 +1085,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1067,8 +1067,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1065,8 +1065,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1059,8 +1059,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -1069,8 +1069,8 @@
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
* Add a bed leveling sub-menu for ABL or MBL.
|
||||
* Include a guided procedure if manual probing is enabled.
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
|
@ -921,8 +921,8 @@ static_assert(X_MAX_LENGTH >= X_BED_SIZE && Y_MAX_LENGTH >= Y_BED_SIZE,
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#if DISABLED(ULTIPANEL)
|
||||
#error "LCD_BED_LEVELING requires an LCD controller."
|
||||
#elif !(ENABLED(MESH_BED_LEVELING) || (OLDSCHOOL_ABL && ENABLED(PROBE_MANUALLY)))
|
||||
#error "LCD_BED_LEVELING requires MESH_BED_LEVELING or ABL with PROBE_MANUALLY."
|
||||
#elif !(ENABLED(MESH_BED_LEVELING) || OLDSCHOOL_ABL)
|
||||
#error "LCD_BED_LEVELING requires MESH_BED_LEVELING or AUTO_BED_LEVELING."
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|
@ -769,7 +769,7 @@
|
||||
#define MSG_FIRST _UxGT("first")
|
||||
#endif
|
||||
#ifndef MSG_ZPROBE_ZOFFSET
|
||||
#define MSG_ZPROBE_ZOFFSET _UxGT("Z Offset")
|
||||
#define MSG_ZPROBE_ZOFFSET _UxGT("Probe Z Offset")
|
||||
#endif
|
||||
#ifndef MSG_BABYSTEP_X
|
||||
#define MSG_BABYSTEP_X _UxGT("Babystep X")
|
||||
|
@ -1404,13 +1404,20 @@ void lcd_quick_feedback(const bool clear_buttons) {
|
||||
//
|
||||
MENU_ITEM_EDIT(int3, MSG_SPEED, &feedrate_percentage, 10, 999);
|
||||
|
||||
//
|
||||
// Manual bed leveling, Bed Z:
|
||||
//
|
||||
#if ENABLED(MESH_BED_LEVELING) && ENABLED(LCD_BED_LEVELING)
|
||||
MENU_ITEM_EDIT(float43, MSG_BED_Z, &mbl.z_offset, -1, 1);
|
||||
#endif
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
|
||||
//
|
||||
// Leveling Fade Height
|
||||
//
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT) && DISABLED(SLIM_LCD_MENUS)
|
||||
MENU_MULTIPLIER_ITEM_EDIT_CALLBACK(float62, MSG_Z_FADE_HEIGHT, &new_z_fade_height, 0.0, 100.0, _lcd_set_z_fade_height);
|
||||
#endif
|
||||
|
||||
//
|
||||
// Nozzle:
|
||||
// Nozzle [1-4]:
|
||||
@ -1883,7 +1890,7 @@ void lcd_quick_feedback(const bool clear_buttons) {
|
||||
|
||||
#endif // LEVEL_BED_CORNERS
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#if ENABLED(LCD_BED_LEVELING) && (ENABLED(PROBE_MANUALLY) || ENABLED(MESH_BED_LEVELING))
|
||||
|
||||
/**
|
||||
*
|
||||
@ -2045,76 +2052,6 @@ void lcd_quick_feedback(const bool clear_buttons) {
|
||||
enqueue_and_echo_commands_P(PSTR("G28"));
|
||||
}
|
||||
|
||||
static bool new_level_state;
|
||||
void _lcd_toggle_bed_leveling() { set_bed_leveling_enabled(new_level_state); }
|
||||
|
||||
/**
|
||||
* Step 1: Bed Level entry-point
|
||||
*
|
||||
* << Prepare
|
||||
* Auto Home (if homing needed)
|
||||
* Leveling On/Off (if data exists, and homed)
|
||||
* Fade Height: --- (Req: ENABLE_LEVELING_FADE_HEIGHT)
|
||||
* Mesh Z Offset: --- (Req: MESH_BED_LEVELING)
|
||||
* Z Probe Offset: --- (Req: HAS_BED_PROBE, Opt: BABYSTEP_ZPROBE_OFFSET)
|
||||
* Level Bed >
|
||||
* Level Corners > (if homed)
|
||||
* Load Settings (Req: EEPROM_SETTINGS)
|
||||
* Save Settings (Req: EEPROM_SETTINGS)
|
||||
*/
|
||||
void lcd_bed_leveling() {
|
||||
START_MENU();
|
||||
MENU_BACK(MSG_PREPARE);
|
||||
|
||||
#if DISABLED(MESH_BED_LEVELING)
|
||||
if (!(axis_known_position[X_AXIS] && axis_known_position[Y_AXIS] && axis_known_position[Z_AXIS]))
|
||||
MENU_ITEM(gcode, MSG_AUTO_HOME, PSTR("G28"));
|
||||
else
|
||||
#endif
|
||||
if (leveling_is_valid()) {
|
||||
new_level_state = planner.leveling_active;
|
||||
MENU_ITEM_EDIT_CALLBACK(bool, MSG_BED_LEVELING, &new_level_state, _lcd_toggle_bed_leveling);
|
||||
}
|
||||
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
MENU_MULTIPLIER_ITEM_EDIT_CALLBACK(float62, MSG_Z_FADE_HEIGHT, &new_z_fade_height, 0.0, 100.0, _lcd_set_z_fade_height);
|
||||
#endif
|
||||
|
||||
//
|
||||
// MBL Z Offset
|
||||
//
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
MENU_ITEM_EDIT(float43, MSG_BED_Z, &mbl.z_offset, -1, 1);
|
||||
#endif
|
||||
|
||||
#if ENABLED(BABYSTEP_ZPROBE_OFFSET)
|
||||
MENU_ITEM(submenu, MSG_ZPROBE_ZOFFSET, lcd_babystep_zoffset);
|
||||
#elif HAS_BED_PROBE
|
||||
MENU_ITEM_EDIT(float52, MSG_ZPROBE_ZOFFSET, &zprobe_zoffset, Z_PROBE_OFFSET_RANGE_MIN, Z_PROBE_OFFSET_RANGE_MAX);
|
||||
#endif
|
||||
|
||||
MENU_ITEM(submenu, MSG_LEVEL_BED, _lcd_level_bed_continue);
|
||||
|
||||
#if ENABLED(LEVEL_BED_CORNERS)
|
||||
// Move to the next corner for leveling
|
||||
if (axis_homed[X_AXIS] && axis_homed[Y_AXIS] && axis_homed[Z_AXIS])
|
||||
MENU_ITEM(submenu, MSG_LEVEL_CORNERS, _lcd_level_bed_corners);
|
||||
#endif
|
||||
|
||||
#if ENABLED(EEPROM_SETTINGS)
|
||||
MENU_ITEM(function, MSG_LOAD_EEPROM, lcd_load_settings);
|
||||
MENU_ITEM(function, MSG_STORE_EEPROM, lcd_store_settings);
|
||||
#endif
|
||||
END_MENU();
|
||||
}
|
||||
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
void _lcd_goto_bed_leveling() {
|
||||
lcd_goto_screen(lcd_bed_leveling);
|
||||
new_z_fade_height = planner.z_fade_height;
|
||||
}
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
void _lcd_ubl_level_bed();
|
||||
@ -2647,6 +2584,93 @@ void lcd_quick_feedback(const bool clear_buttons) {
|
||||
|
||||
#endif // AUTO_BED_LEVELING_UBL
|
||||
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING) || (PLANNER_LEVELING && DISABLED(SLIM_LCD_MENUS))
|
||||
void _lcd_toggle_bed_leveling() { set_bed_leveling_enabled(!planner.leveling_active); }
|
||||
#endif
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
|
||||
/**
|
||||
* Step 1: Bed Level entry-point
|
||||
*
|
||||
* << Prepare
|
||||
* Auto Home (if homing needed)
|
||||
* Leveling On/Off (if data exists, and homed)
|
||||
* Fade Height: --- (Req: ENABLE_LEVELING_FADE_HEIGHT)
|
||||
* Mesh Z Offset: --- (Req: MESH_BED_LEVELING)
|
||||
* Z Probe Offset: --- (Req: HAS_BED_PROBE, Opt: BABYSTEP_ZPROBE_OFFSET)
|
||||
* Level Bed >
|
||||
* Level Corners > (if homed)
|
||||
* Load Settings (Req: EEPROM_SETTINGS)
|
||||
* Save Settings (Req: EEPROM_SETTINGS)
|
||||
*/
|
||||
void lcd_bed_leveling() {
|
||||
START_MENU();
|
||||
MENU_BACK(MSG_PREPARE);
|
||||
|
||||
const bool is_homed = axis_known_position[X_AXIS] && axis_known_position[Y_AXIS] && axis_known_position[Z_AXIS];
|
||||
|
||||
// Auto Home if not using manual probing
|
||||
#if DISABLED(PROBE_MANUALLY) && DISABLED(MESH_BED_LEVELING)
|
||||
if (!is_homed) MENU_ITEM(gcode, MSG_AUTO_HOME, PSTR("G28"));
|
||||
#endif
|
||||
|
||||
// Level Bed
|
||||
#if ENABLED(PROBE_MANUALLY) || ENABLED(MESH_BED_LEVELING)
|
||||
// Manual leveling uses a guided procedure
|
||||
MENU_ITEM(submenu, MSG_LEVEL_BED, _lcd_level_bed_continue);
|
||||
#else
|
||||
// Automatic leveling can just run the G-code
|
||||
MENU_ITEM(gcode, MSG_LEVEL_BED, is_homed ? PSTR("G29") : PSTR("G28\nG29"));
|
||||
#endif
|
||||
|
||||
// Homed and leveling is valid? Then leveling can be toggled.
|
||||
if (is_homed && leveling_is_valid()) {
|
||||
bool new_level_state = planner.leveling_active;
|
||||
MENU_ITEM_EDIT_CALLBACK(bool, MSG_BED_LEVELING, &new_level_state, _lcd_toggle_bed_leveling);
|
||||
}
|
||||
|
||||
// Z Fade Height
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
MENU_MULTIPLIER_ITEM_EDIT_CALLBACK(float62, MSG_Z_FADE_HEIGHT, &new_z_fade_height, 0.0, 100.0, _lcd_set_z_fade_height);
|
||||
#endif
|
||||
|
||||
//
|
||||
// MBL Z Offset
|
||||
//
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
MENU_ITEM_EDIT(float43, MSG_BED_Z, &mbl.z_offset, -1, 1);
|
||||
#endif
|
||||
|
||||
#if ENABLED(BABYSTEP_ZPROBE_OFFSET)
|
||||
MENU_ITEM(submenu, MSG_ZPROBE_ZOFFSET, lcd_babystep_zoffset);
|
||||
#elif HAS_BED_PROBE
|
||||
MENU_ITEM_EDIT(float52, MSG_ZPROBE_ZOFFSET, &zprobe_zoffset, Z_PROBE_OFFSET_RANGE_MIN, Z_PROBE_OFFSET_RANGE_MAX);
|
||||
#endif
|
||||
|
||||
#if ENABLED(LEVEL_BED_CORNERS)
|
||||
// Move to the next corner for leveling
|
||||
if (axis_homed[X_AXIS] && axis_homed[Y_AXIS] && axis_homed[Z_AXIS])
|
||||
MENU_ITEM(submenu, MSG_LEVEL_CORNERS, _lcd_level_bed_corners);
|
||||
#endif
|
||||
|
||||
#if ENABLED(EEPROM_SETTINGS)
|
||||
MENU_ITEM(function, MSG_LOAD_EEPROM, lcd_load_settings);
|
||||
MENU_ITEM(function, MSG_STORE_EEPROM, lcd_store_settings);
|
||||
#endif
|
||||
END_MENU();
|
||||
}
|
||||
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
void _lcd_goto_bed_leveling() {
|
||||
lcd_goto_screen(lcd_bed_leveling);
|
||||
new_z_fade_height = planner.z_fade_height;
|
||||
}
|
||||
#endif
|
||||
|
||||
#endif // LCD_BED_LEVELING
|
||||
|
||||
/**
|
||||
*
|
||||
* "Prepare" submenu
|
||||
@ -2683,26 +2707,44 @@ void lcd_quick_feedback(const bool clear_buttons) {
|
||||
// Level Bed
|
||||
//
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
MENU_ITEM(submenu, MSG_UBL_LEVEL_BED,
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
_lcd_goto_ubl_level_bed
|
||||
#else
|
||||
_lcd_ubl_level_bed
|
||||
#endif
|
||||
|
||||
MENU_ITEM(submenu, MSG_UBL_LEVEL_BED, (
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
_lcd_goto_ubl_level_bed
|
||||
#else
|
||||
_lcd_ubl_level_bed
|
||||
#endif
|
||||
)
|
||||
);
|
||||
|
||||
#elif ENABLED(LCD_BED_LEVELING)
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
if (!g29_in_progress)
|
||||
#endif
|
||||
MENU_ITEM(submenu, MSG_BED_LEVELING,
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
_lcd_goto_bed_leveling
|
||||
#else
|
||||
lcd_bed_leveling
|
||||
#endif
|
||||
|
||||
MENU_ITEM(submenu, MSG_BED_LEVELING, (
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
_lcd_goto_bed_leveling
|
||||
#else
|
||||
lcd_bed_leveling
|
||||
#endif
|
||||
)
|
||||
);
|
||||
#elif PLANNER_LEVELING && DISABLED(PROBE_MANUALLY) && DISABLED(SLIM_LCD_MENUS)
|
||||
MENU_ITEM(gcode, MSG_BED_LEVELING, PSTR("G28\nG29"));
|
||||
|
||||
#elif PLANNER_LEVELING && DISABLED(SLIM_LCD_MENUS)
|
||||
|
||||
#if DISABLED(PROBE_MANUALLY)
|
||||
MENU_ITEM(gcode, MSG_LEVEL_BED, PSTR("G28\nG29"));
|
||||
#endif
|
||||
if (leveling_is_valid()) {
|
||||
bool new_level_state = planner.leveling_active;
|
||||
MENU_ITEM_EDIT_CALLBACK(bool, MSG_BED_LEVELING, &new_level_state, _lcd_toggle_bed_leveling);
|
||||
}
|
||||
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
||||
MENU_MULTIPLIER_ITEM_EDIT_CALLBACK(float62, MSG_Z_FADE_HEIGHT, &new_z_fade_height, 0.0, 100.0, _lcd_set_z_fade_height);
|
||||
#endif
|
||||
|
||||
#endif
|
||||
|
||||
#if ENABLED(LEVEL_BED_CORNERS) && DISABLED(LCD_BED_LEVELING)
|
||||
|
Loading…
Reference in New Issue
Block a user