Update SKR mini configs
This commit is contained in:
parent
2d74c2042a
commit
4d8e7cdb30
@ -197,6 +197,56 @@
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
#define LPQ_MAX_LEN 50
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Add an experimental additional term to the heater power, proportional to the fan speed.
|
||||
* A well-chosen Kf value should add just enough power to compensate for power-loss from the cooling fan.
|
||||
* You can either just add a constant compensation with the DEFAULT_Kf value
|
||||
* or follow the instruction below to get speed-dependent compensation.
|
||||
*
|
||||
* Constant compensation (use only with fanspeeds of 0% and 100%)
|
||||
* ---------------------------------------------------------------------
|
||||
* A good starting point for the Kf-value comes from the calculation:
|
||||
* kf = (power_fan * eff_fan) / power_heater * 255
|
||||
* where eff_fan is between 0.0 and 1.0, based on fan-efficiency and airflow to the nozzle / heater.
|
||||
*
|
||||
* Example:
|
||||
* Heater: 40W, Fan: 0.1A * 24V = 2.4W, eff_fan = 0.8
|
||||
* Kf = (2.4W * 0.8) / 40W * 255 = 12.24
|
||||
*
|
||||
* Fan-speed dependent compensation
|
||||
* --------------------------------
|
||||
* 1. To find a good Kf value, set the hotend temperature, wait for it to settle, and enable the fan (100%).
|
||||
* Make sure PID_FAN_SCALING_LIN_FACTOR is 0 and PID_FAN_SCALING_ALTERNATIVE_DEFINITION is not enabled.
|
||||
* If you see the temperature drop repeat the test, increasing the Kf value slowly, until the temperature
|
||||
* drop goes away. If the temperature overshoots after enabling the fan, the Kf value is too big.
|
||||
* 2. Note the Kf-value for fan-speed at 100%
|
||||
* 3. Determine a good value for PID_FAN_SCALING_MIN_SPEED, which is around the speed, where the fan starts moving.
|
||||
* 4. Repeat step 1. and 2. for this fan speed.
|
||||
* 5. Enable PID_FAN_SCALING_ALTERNATIVE_DEFINITION and enter the two identified Kf-values in
|
||||
* PID_FAN_SCALING_AT_FULL_SPEED and PID_FAN_SCALING_AT_MIN_SPEED. Enter the minimum speed in PID_FAN_SCALING_MIN_SPEED
|
||||
*/
|
||||
//#define PID_FAN_SCALING
|
||||
#if ENABLED(PID_FAN_SCALING)
|
||||
//#define PID_FAN_SCALING_ALTERNATIVE_DEFINITION
|
||||
#if ENABLED(PID_FAN_SCALING_ALTERNATIVE_DEFINITION)
|
||||
// The alternative definition is used for an easier configuration.
|
||||
// Just figure out Kf at fullspeed (255) and PID_FAN_SCALING_MIN_SPEED.
|
||||
// DEFAULT_Kf and PID_FAN_SCALING_LIN_FACTOR are calculated accordingly.
|
||||
|
||||
#define PID_FAN_SCALING_AT_FULL_SPEED 13.0 //=PID_FAN_SCALING_LIN_FACTOR*255+DEFAULT_Kf
|
||||
#define PID_FAN_SCALING_AT_MIN_SPEED 6.0 //=PID_FAN_SCALING_LIN_FACTOR*PID_FAN_SCALING_MIN_SPEED+DEFAULT_Kf
|
||||
#define PID_FAN_SCALING_MIN_SPEED 10.0 // Minimum fan speed at which to enable PID_FAN_SCALING
|
||||
|
||||
#define DEFAULT_Kf (255.0*PID_FAN_SCALING_AT_MIN_SPEED-PID_FAN_SCALING_AT_FULL_SPEED*PID_FAN_SCALING_MIN_SPEED)/(255.0-PID_FAN_SCALING_MIN_SPEED)
|
||||
#define PID_FAN_SCALING_LIN_FACTOR (PID_FAN_SCALING_AT_FULL_SPEED-DEFAULT_Kf)/255.0
|
||||
|
||||
#else
|
||||
#define PID_FAN_SCALING_LIN_FACTOR (0) // Power loss due to cooling = Kf * (fan_speed)
|
||||
#define DEFAULT_Kf 10 // A constant value added to the PID-tuner
|
||||
#define PID_FAN_SCALING_MIN_SPEED 10 // Minimum fan speed at which to enable PID_FAN_SCALING
|
||||
#endif
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
@ -960,6 +1010,8 @@
|
||||
*/
|
||||
//#define POWER_LOSS_RECOVERY
|
||||
#if ENABLED(POWER_LOSS_RECOVERY)
|
||||
//#define BACKUP_POWER_SUPPLY // Backup power / UPS to move the steppers on power loss
|
||||
//#define POWER_LOSS_ZRAISE 2 // (mm) Z axis raise on resume (on power loss with UPS)
|
||||
//#define POWER_LOSS_PIN 44 // Pin to detect power loss
|
||||
//#define POWER_LOSS_STATE HIGH // State of pin indicating power loss
|
||||
//#define POWER_LOSS_PULL // Set pullup / pulldown as appropriate
|
||||
|
@ -197,6 +197,56 @@
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
#define LPQ_MAX_LEN 50
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Add an experimental additional term to the heater power, proportional to the fan speed.
|
||||
* A well-chosen Kf value should add just enough power to compensate for power-loss from the cooling fan.
|
||||
* You can either just add a constant compensation with the DEFAULT_Kf value
|
||||
* or follow the instruction below to get speed-dependent compensation.
|
||||
*
|
||||
* Constant compensation (use only with fanspeeds of 0% and 100%)
|
||||
* ---------------------------------------------------------------------
|
||||
* A good starting point for the Kf-value comes from the calculation:
|
||||
* kf = (power_fan * eff_fan) / power_heater * 255
|
||||
* where eff_fan is between 0.0 and 1.0, based on fan-efficiency and airflow to the nozzle / heater.
|
||||
*
|
||||
* Example:
|
||||
* Heater: 40W, Fan: 0.1A * 24V = 2.4W, eff_fan = 0.8
|
||||
* Kf = (2.4W * 0.8) / 40W * 255 = 12.24
|
||||
*
|
||||
* Fan-speed dependent compensation
|
||||
* --------------------------------
|
||||
* 1. To find a good Kf value, set the hotend temperature, wait for it to settle, and enable the fan (100%).
|
||||
* Make sure PID_FAN_SCALING_LIN_FACTOR is 0 and PID_FAN_SCALING_ALTERNATIVE_DEFINITION is not enabled.
|
||||
* If you see the temperature drop repeat the test, increasing the Kf value slowly, until the temperature
|
||||
* drop goes away. If the temperature overshoots after enabling the fan, the Kf value is too big.
|
||||
* 2. Note the Kf-value for fan-speed at 100%
|
||||
* 3. Determine a good value for PID_FAN_SCALING_MIN_SPEED, which is around the speed, where the fan starts moving.
|
||||
* 4. Repeat step 1. and 2. for this fan speed.
|
||||
* 5. Enable PID_FAN_SCALING_ALTERNATIVE_DEFINITION and enter the two identified Kf-values in
|
||||
* PID_FAN_SCALING_AT_FULL_SPEED and PID_FAN_SCALING_AT_MIN_SPEED. Enter the minimum speed in PID_FAN_SCALING_MIN_SPEED
|
||||
*/
|
||||
//#define PID_FAN_SCALING
|
||||
#if ENABLED(PID_FAN_SCALING)
|
||||
//#define PID_FAN_SCALING_ALTERNATIVE_DEFINITION
|
||||
#if ENABLED(PID_FAN_SCALING_ALTERNATIVE_DEFINITION)
|
||||
// The alternative definition is used for an easier configuration.
|
||||
// Just figure out Kf at fullspeed (255) and PID_FAN_SCALING_MIN_SPEED.
|
||||
// DEFAULT_Kf and PID_FAN_SCALING_LIN_FACTOR are calculated accordingly.
|
||||
|
||||
#define PID_FAN_SCALING_AT_FULL_SPEED 13.0 //=PID_FAN_SCALING_LIN_FACTOR*255+DEFAULT_Kf
|
||||
#define PID_FAN_SCALING_AT_MIN_SPEED 6.0 //=PID_FAN_SCALING_LIN_FACTOR*PID_FAN_SCALING_MIN_SPEED+DEFAULT_Kf
|
||||
#define PID_FAN_SCALING_MIN_SPEED 10.0 // Minimum fan speed at which to enable PID_FAN_SCALING
|
||||
|
||||
#define DEFAULT_Kf (255.0*PID_FAN_SCALING_AT_MIN_SPEED-PID_FAN_SCALING_AT_FULL_SPEED*PID_FAN_SCALING_MIN_SPEED)/(255.0-PID_FAN_SCALING_MIN_SPEED)
|
||||
#define PID_FAN_SCALING_LIN_FACTOR (PID_FAN_SCALING_AT_FULL_SPEED-DEFAULT_Kf)/255.0
|
||||
|
||||
#else
|
||||
#define PID_FAN_SCALING_LIN_FACTOR (0) // Power loss due to cooling = Kf * (fan_speed)
|
||||
#define DEFAULT_Kf 10 // A constant value added to the PID-tuner
|
||||
#define PID_FAN_SCALING_MIN_SPEED 10 // Minimum fan speed at which to enable PID_FAN_SCALING
|
||||
#endif
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
|
Loading…
Reference in New Issue
Block a user