Merge pull request #1037 from filipmu/Filament-Sensor
Support for a filament diameter sensor
This commit is contained in:
@ -193,7 +193,7 @@
|
||||
// is more then PID_FUNCTIONAL_RANGE then the PID will be shut off and the heater will be set to min/max.
|
||||
#define PID_INTEGRAL_DRIVE_MAX 255 //limit for the integral term
|
||||
#define K1 0.95 //smoothing factor within the PID
|
||||
#define PID_dT ((OVERSAMPLENR * 8.0)/(F_CPU / 64.0 / 256.0)) //sampling period of the temperature routine
|
||||
#define PID_dT ((OVERSAMPLENR * 10.0)/(F_CPU / 64.0 / 256.0)) //sampling period of the temperature routine
|
||||
|
||||
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
|
||||
// Ultimaker
|
||||
@ -766,6 +766,35 @@ const bool Z_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of
|
||||
//#define SERVO_ENDSTOPS {-1, -1, 0} // Servo index for X, Y, Z. Disable with -1
|
||||
//#define SERVO_ENDSTOP_ANGLES {0,0, 0,0, 70,0} // X,Y,Z Axis Extend and Retract angles
|
||||
|
||||
/**********************************************************************\
|
||||
* Support for a filament diameter sensor
|
||||
* Also allows adjustment of diameter at print time (vs at slicing)
|
||||
* Single extruder only at this point (extruder 0)
|
||||
*
|
||||
* Motherboards
|
||||
* 34 - RAMPS1.4 - uses Analog input 5 on the AUX2 connector
|
||||
* 81 - Printrboard - Uses Analog input 2 on the Aux 2 connector
|
||||
* 301 - Rambo - uses Analog input 3
|
||||
* Note may require analog pins to be defined for different motherboards
|
||||
**********************************************************************/
|
||||
#define FILAMENT_SENSOR
|
||||
#define FILAMENT_SENSOR_EXTRUDER_NUM 0 //The number of the extruder that has the filament sensor (0,1,2)
|
||||
#define MEASUREMENT_DELAY_CM 14 //measurement delay in cm. This is the distance from filament sensor to middle of barrel
|
||||
|
||||
#define DEFAULT_NOMINAL_FILAMENT_DIA 3.0 //Enter the diameter (in mm) of the filament generally used (3.0 mm or 1.75 mm) - this is then used in the slicer software. Used for sensor reading validation
|
||||
#define MEASURED_UPPER_LIMIT 3.30 //upper limit factor used for sensor reading validation in mm
|
||||
#define MEASURED_LOWER_LIMIT 1.90 //lower limit factor for sensor reading validation in mm
|
||||
#define MAX_MEASUREMENT_DELAY 20 //delay buffer size in bytes (1 byte = 1cm)- limits maximum measurement delay allowable (must be larger than MEASUREMENT_DELAY_CM and lower number saves RAM)
|
||||
|
||||
//defines used in the code
|
||||
#define DEFAULT_MEASURED_FILAMENT_DIA DEFAULT_NOMINAL_FILAMENT_DIA //set measured to nominal initially
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||