Marlin_Firmware/Marlin/ubl_G29.cpp
LVD-AC 567941e341 Fix for issues #6997 and #7152
Probing with the effector in the printing area, but an eccentric probe (e.g. allen key) outside it but still touching the bed gives meaninfull information for calibration. Since calibration is most accurate when probing as close to the towers as possible the testing was way to restrictive hence this fix.
2017-07-03 02:53:49 -05:00

1832 lines
75 KiB
C++

/**
* Marlin 3D Printer Firmware
* Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*
*/
#include "MarlinConfig.h"
#if ENABLED(AUTO_BED_LEVELING_UBL)
#include "ubl.h"
#include "Marlin.h"
#include "hex_print_routines.h"
#include "configuration_store.h"
#include "ultralcd.h"
#include "stepper.h"
#include "planner.h"
#include "gcode.h"
#include <math.h>
#include "least_squares_fit.h"
#define UBL_G29_P31
extern float destination[XYZE], current_position[XYZE];
#if ENABLED(NEWPANEL)
void lcd_return_to_status();
void lcd_mesh_edit_setup(float initial);
float lcd_mesh_edit();
void lcd_z_offset_edit_setup(float);
extern void _lcd_ubl_output_map_lcd();
float lcd_z_offset_edit();
#endif
extern float meshedit_done;
extern long babysteps_done;
extern float probe_pt(const float &lx, const float &ly, const bool, const uint8_t, const bool=true);
extern bool set_probe_deployed(bool);
extern void set_bed_leveling_enabled(bool);
typedef void (*screenFunc_t)();
extern void lcd_goto_screen(screenFunc_t screen, const uint32_t encoder = 0);
#define SIZE_OF_LITTLE_RAISE 1
#define BIG_RAISE_NOT_NEEDED 0
int unified_bed_leveling::g29_verbose_level,
unified_bed_leveling::g29_phase_value,
unified_bed_leveling::g29_repetition_cnt,
unified_bed_leveling::g29_storage_slot = 0,
unified_bed_leveling::g29_map_type,
unified_bed_leveling::g29_grid_size;
bool unified_bed_leveling::g29_c_flag,
unified_bed_leveling::g29_x_flag,
unified_bed_leveling::g29_y_flag;
float unified_bed_leveling::g29_x_pos,
unified_bed_leveling::g29_y_pos,
unified_bed_leveling::g29_card_thickness = 0.0,
unified_bed_leveling::g29_constant = 0.0;
/**
* G29: Unified Bed Leveling by Roxy
*
* Parameters understood by this leveling system:
*
* A Activate Activate the Unified Bed Leveling system.
*
* B # Business Use the 'Business Card' mode of the Manual Probe subsystem with P2.
* Note: A non-compressible Spark Gap feeler gauge is recommended over a business card.
* In this mode of G29 P2, a business or index card is used as a shim that the nozzle can
* grab onto as it is lowered. In principle, the nozzle-bed distance is the same when the
* same resistance is felt in the shim. You can omit the numerical value on first invocation
* of G29 P2 B to measure shim thickness. Subsequent use of 'B' will apply the previously-
* measured thickness by default.
*
* C Continue G29 P1 C continues the generation of a partially-constructed Mesh without invalidating
* previous measurements.
*
* C Constant G29 P2 C specifies a Constant and tells the Manual Probe subsystem to use the current
* location in its search for the closest unmeasured Mesh Point.
*
* G29 P3 C specifies the Constant for the fill. Otherwise, uses a "reasonable" value.
*
* C Current G29 Z C uses the Current location (instead of bed center or nearest edge).
*
* D Disable Disable the Unified Bed Leveling system.
*
* E Stow_probe Stow the probe after each sampled point.
*
* F # Fade Fade the amount of Mesh Based Compensation over a specified height. At the
* specified height, no correction is applied and natural printer kenimatics take over. If no
* number is specified for the command, 10mm is assumed to be reasonable.
*
* H # Height With P2, 'H' specifies the Height to raise the nozzle after each manual probe of the bed.
* If omitted, the nozzle will raise by Z_CLEARANCE_BETWEEN_PROBES.
*
* H # Offset With P4, 'H' specifies the Offset above the mesh height to place the nozzle.
* If omitted, Z_CLEARANCE_BETWEEN_PROBES will be used.
*
* I # Invalidate Invalidate the specified number of Mesh Points near the given 'X' 'Y'. If X or Y are omitted,
* the nozzle location is used. If no 'I' value is given, only the point nearest to the location
* is invalidated. Use 'T' to produce a map afterward. This command is useful to invalidate a
* portion of the Mesh so it can be adjusted using other UBL tools. When attempting to invalidate
* an isolated bad mesh point, the 'T' option shows the nozzle position in the Mesh with (#). You
* can move the nozzle around and use this feature to select the center of the area (or cell) to
* invalidate.
*
* J # Grid Perform a Grid Based Leveling of the current Mesh using a grid with n points on a side.
* Not specifying a grid size will invoke the 3-Point leveling function.
*
* K # Kompare Kompare current Mesh with stored Mesh # replacing current Mesh with the result. This
* command literally performs a diff between two Meshes.
*
* L Load Load Mesh from the previously activated location in the EEPROM.
*
* L # Load Load Mesh from the specified location in the EEPROM. Set this location as activated
* for subsequent Load and Store operations.
*
* The P or Phase commands are used for the bulk of the work to setup a Mesh. In general, your Mesh will
* start off being initialized with a G29 P0 or a G29 P1. Further refinement of the Mesh happens with
* each additional Phase that processes it.
*
* P0 Phase 0 Zero Mesh Data and turn off the Mesh Compensation System. This reverts the
* 3D Printer to the same state it was in before the Unified Bed Leveling Compensation
* was turned on. Setting the entire Mesh to Zero is a special case that allows
* a subsequent G or T leveling operation for backward compatibility.
*
* P1 Phase 1 Invalidate entire Mesh and continue with automatic generation of the Mesh data using
* the Z-Probe. Usually the probe can't reach all areas that the nozzle can reach. On
* Cartesian printers, points within the X_PROBE_OFFSET_FROM_EXTRUDER and Y_PROBE_OFFSET_FROM_EXTRUDER
* area cannot be automatically probed. For Delta printers the area in which DELTA_PROBEABLE_RADIUS
* and DELTA_PRINTABLE_RADIUS do not overlap will not be automatically probed.
*
* Unreachable points will be handled in Phase 2 and Phase 3.
*
* Use 'C' to leave the previous mesh intact and automatically probe needed points. This allows you
* to invalidate parts of the Mesh but still use Automatic Probing.
*
* The 'X' and 'Y' parameters prioritize where to try and measure points. If omitted, the current
* probe position is used.
*
* Use 'T' (Topology) to generate a report of mesh generation.
*
* P1 will suspend Mesh generation if the controller button is held down. Note that you may need
* to press and hold the switch for several seconds if moves are underway.
*
* P2 Phase 2 Probe unreachable points.
*
* Use 'H' to set the height between Mesh points. If omitted, Z_CLEARANCE_BETWEEN_PROBES is used.
* Smaller values will be quicker. Move the nozzle down till it barely touches the bed. Make sure the
* nozzle is clean and unobstructed. Use caution and move slowly. This can damage your printer!
* (Uses SIZE_OF_LITTLE_RAISE mm if the nozzle is moving less than BIG_RAISE_NOT_NEEDED mm.)
*
* The 'H' value can be negative if the Mesh dips in a large area. Press and hold the
* controller button to terminate the current Phase 2 command. You can then re-issue "G29 P 2"
* with an 'H' parameter more suitable for the area you're manually probing. Note that the command
* tries to start in a corner of the bed where movement will be predictable. Override the distance
* calculation location with the X and Y parameters. You can print a Mesh Map (G29 T) to see where
* the mesh is invalidated and where the nozzle needs to move to complete the command. Use 'C' to
* indicate that the search should be based on the current position.
*
* The 'B' parameter for this command is described above. It places the manual probe subsystem into
* Business Card mode where the thickness of a business card is measured and then used to accurately
* set the nozzle height in all manual probing for the duration of the command. A Business card can
* be used, but you'll get better results with a flexible Shim that doesn't compress. This makes it
* easier to produce similar amounts of force and get more accurate measurements. Google if you're
* not sure how to use a shim.
*
* The 'T' (Map) parameter helps track Mesh building progress.
*
* NOTE: P2 requires an LCD controller!
*
* P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value. There are two different paths to
* go down:
*
* - If a 'C' constant is specified, the closest invalid mesh points to the nozzle will be filled,
* and a repeat count can then also be specified with 'R'.
*
* - Leaving out 'C' invokes Smart Fill, which scans the mesh from the edges inward looking for
* invalid mesh points. Adjacent points are used to determine the bed slope. If the bed is sloped
* upward from the invalid point, it takes the value of the nearest point. If sloped downward, it's
* replaced by a value that puts all three points in a line. This version of G29 P3 is a quick, easy
* and (usually) safe way to populate unprobed mesh regions before continuing to G26 Mesh Validation
* Pattern. Note that this populates the mesh with unverified values. Pay attention and use caution.
*
* P4 Phase 4 Fine tune the Mesh. The Delta Mesh Compensation System assumes the existence of
* an LCD Panel. It is possible to fine tune the mesh without an LCD Panel using
* G42 and M421. See the UBL documentation for further details.
*
* Phase 4 is meant to be used with G26 Mesh Validation to fine tune the mesh by direct editing
* of Mesh Points. Raise and lower points to fine tune the mesh until it gives consistently reliable
* adhesion.
*
* P4 moves to the closest Mesh Point (and/or the given X Y), raises the nozzle above the mesh height
* by the given 'H' offset (or default Z_CLEARANCE_BETWEEN_PROBES), and waits while the controller is
* used to adjust the nozzle height. On click the displayed height is saved in the mesh.
*
* Start Phase 4 at a specific location with X and Y. Adjust a specific number of Mesh Points with
* the 'R' (Repeat) parameter. (If 'R' is left out, the whole matrix is assumed.) This command can be
* terminated early (e.g., after editing the area of interest) by pressing and holding the encoder button.
*
* The general form is G29 P4 [R points] [X position] [Y position]
*
* The H [offset] parameter is useful if a shim is used to fine-tune the mesh. For a 0.4mm shim the
* command would be G29 P4 H0.4. The nozzle is moved to the shim height, you adjust height to the shim,
* and on click the height minus the shim thickness will be saved in the mesh.
*
* !!Use with caution, as a very poor mesh could cause the nozzle to crash into the bed!!
*
* NOTE: P4 is not available unless you have LCD support enabled!
*
* P5 Phase 5 Find Mean Mesh Height and Standard Deviation. Typically, it is easier to use and
* work with the Mesh if it is Mean Adjusted. You can specify a C parameter to
* Correct the Mesh to a 0.00 Mean Height. Adding a C parameter will automatically
* execute a G29 P6 C <mean height>.
*
* P6 Phase 6 Shift Mesh height. The entire Mesh's height is adjusted by the height specified
* with the C parameter. Being able to adjust the height of a Mesh is useful tool. It
* can be used to compensate for poorly calibrated Z-Probes and other errors. Ideally,
* you should have the Mesh adjusted for a Mean Height of 0.00 and the Z-Probe measuring
* 0.000 at the Z Home location.
*
* Q Test Load specified Test Pattern to assist in checking correct operation of system. This
* command is not anticipated to be of much value to the typical user. It is intended
* for developers to help them verify correct operation of the Unified Bed Leveling System.
*
* R # Repeat Repeat this command the specified number of times. If no number is specified the
* command will be repeated GRID_MAX_POINTS_X * GRID_MAX_POINTS_Y times.
*
* S Store Store the current Mesh in the Activated area of the EEPROM. It will also store the
* current state of the Unified Bed Leveling system in the EEPROM.
*
* S # Store Store the current Mesh at the specified location in EEPROM. Activate this location
* for subsequent Load and Store operations. Valid storage slot numbers begin at 0 and
* extend to a limit related to the available EEPROM storage.
*
* S -1 Store Store the current Mesh as a print out that is suitable to be feed back into the system
* at a later date. The GCode output can be saved and later replayed by the host software
* to reconstruct the current mesh on another machine.
*
* T Topology Display the Mesh Map Topology.
* 'T' can be used alone (e.g., G29 T) or in combination with most of the other commands.
* This option works with all Phase commands (e.g., G29 P4 R 5 T X 50 Y100 C -.1 O)
* This parameter can also specify a Map Type. T0 (the default) is user-readable. T1 can
* is suitable to paste into a spreadsheet for a 3D graph of the mesh.
*
* U Unlevel Perform a probe of the outer perimeter to assist in physically leveling unlevel beds.
* Only used for G29 P1 T U. This speeds up the probing of the edge of the bed. Useful
* when the entire bed doesn't need to be probed because it will be adjusted.
*
* V # Verbosity Set the verbosity level (0-4) for extra details. (Default 0)
*
* W What? Display valuable Unified Bed Leveling System data.
*
* X # X Location for this command
*
* Y # Y Location for this command
*
*
* Release Notes:
* You MUST do M502, M500 to initialize the storage. Failure to do this will cause all
* kinds of problems. Enabling EEPROM Storage is highly recommended. With EEPROM Storage
* of the mesh, you are limited to 3-Point and Grid Leveling. (G29 P0 T and G29 P0 G
* respectively.)
*
* When you do a G28 and then a G29 P1 to automatically build your first mesh, you are going to notice
* the Unified Bed Leveling probes points further and further away from the starting location. (The
* starting location defaults to the center of the bed.) The original Grid and Mesh leveling used
* a Zig Zag pattern. The new pattern is better, especially for people with Delta printers. This
* allows you to get the center area of the Mesh populated (and edited) quicker. This allows you to
* perform a small print and check out your settings quicker. You do not need to populate the
* entire mesh to use it. (You don't want to spend a lot of time generating a mesh only to realize
* you don't have the resolution or zprobe_zoffset set correctly. The Mesh generation
* gathers points closest to where the nozzle is located unless you specify an (X,Y) coordinate pair.
*
* The Unified Bed Leveling uses a lot of EEPROM storage to hold its data. And it takes some effort
* to get this Mesh data correct for a user's printer. We do not want this data destroyed as
* new versions of Marlin add or subtract to the items stored in EEPROM. So, for the benefit of
* the users, we store the Mesh data at the end of the EEPROM and do not keep it contiguous with the
* other data stored in the EEPROM. (For sure the developers are going to complain about this, but
* this is going to be helpful to the users!)
*
* The foundation of this Bed Leveling System is built on Epatel's Mesh Bed Leveling code. A big
* 'Thanks!' to him and the creators of 3-Point and Grid Based leveling. Combining their contributions
* we now have the functionality and features of all three systems combined.
*/
void unified_bed_leveling::G29() {
if (!settings.calc_num_meshes()) {
SERIAL_PROTOCOLLNPGM("?You need to enable your EEPROM and initialize it");
SERIAL_PROTOCOLLNPGM("with M502, M500, M501 in that order.\n");
return;
}
// Check for commands that require the printer to be homed
if (axis_unhomed_error()) {
const int8_t p_val = parser.intval('P', -1);
if (p_val == 1 || p_val == 2 || p_val == 4 || parser.seen('J'))
home_all_axes();
}
if (g29_parameter_parsing()) return; // abort if parsing the simple parameters causes a problem,
// Invalidate Mesh Points. This command is a little bit asymmetrical because
// it directly specifies the repetition count and does not use the 'R' parameter.
if (parser.seen('I')) {
uint8_t cnt = 0;
g29_repetition_cnt = parser.has_value() ? parser.value_int() : 1;
if (g29_repetition_cnt >= GRID_MAX_POINTS) {
set_all_mesh_points_to_value(NAN);
}
else {
while (g29_repetition_cnt--) {
if (cnt > 20) { cnt = 0; idle(); }
const mesh_index_pair location = find_closest_mesh_point_of_type(REAL, g29_x_pos, g29_y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false);
if (location.x_index < 0) {
// No more REACHABLE mesh points to invalidate, so we ASSUME the user
// meant to invalidate the ENTIRE mesh, which cannot be done with
// find_closest_mesh_point loop which only returns REACHABLE points.
set_all_mesh_points_to_value(NAN);
SERIAL_PROTOCOLLNPGM("Entire Mesh invalidated.\n");
break; // No more invalid Mesh Points to populate
}
z_values[location.x_index][location.y_index] = NAN;
cnt++;
}
}
SERIAL_PROTOCOLLNPGM("Locations invalidated.\n");
}
if (parser.seen('Q')) {
const int test_pattern = parser.has_value() ? parser.value_int() : -99;
if (!WITHIN(test_pattern, -1, 2)) {
SERIAL_PROTOCOLLNPGM("Invalid test_pattern value. (-1 to 2)\n");
return;
}
SERIAL_PROTOCOLLNPGM("Loading test_pattern values.\n");
switch (test_pattern) {
case -1:
g29_eeprom_dump();
break;
case 0:
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a bowl shape - similar to
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) { // a poorly calibrated Delta.
const float p1 = 0.5 * (GRID_MAX_POINTS_X) - x,
p2 = 0.5 * (GRID_MAX_POINTS_Y) - y;
z_values[x][y] += 2.0 * HYPOT(p1, p2);
}
}
break;
case 1:
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a diagonal line several Mesh cells thick that is raised
z_values[x][x] += 9.999;
z_values[x][x + (x < GRID_MAX_POINTS_Y - 1) ? 1 : -1] += 9.999; // We want the altered line several mesh points thick
}
break;
case 2:
// Allow the user to specify the height because 10mm is a little extreme in some cases.
for (uint8_t x = (GRID_MAX_POINTS_X) / 3; x < 2 * (GRID_MAX_POINTS_X) / 3; x++) // Create a rectangular raised area in
for (uint8_t y = (GRID_MAX_POINTS_Y) / 3; y < 2 * (GRID_MAX_POINTS_Y) / 3; y++) // the center of the bed
z_values[x][y] += parser.seen('C') ? g29_constant : 9.99;
break;
}
}
if (parser.seen('J')) {
if (g29_grid_size) { // if not 0 it is a normal n x n grid being probed
save_ubl_active_state_and_disable();
tilt_mesh_based_on_probed_grid(parser.seen('T'));
restore_ubl_active_state_and_leave();
}
else { // grid_size == 0 : A 3-Point leveling has been requested
float z3, z2, z1 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y), false, g29_verbose_level);
if (!isnan(z1)) {
z2 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y), false, g29_verbose_level);
if (!isnan(z2))
z3 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y), true, g29_verbose_level);
}
if (isnan(z1) || isnan(z2) || isnan(z3)) { // probe_pt will return NAN if unreachable
SERIAL_ERROR_START();
SERIAL_ERRORLNPGM("Attempt to probe off the bed.");
goto LEAVE;
}
// Adjust z1, z2, z3 by the Mesh Height at these points. Just because they're non-zero
// doesn't mean the Mesh is tilted! (Compensate each probe point by what the Mesh says
// its height is.)
save_ubl_active_state_and_disable();
z1 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y)) /* + zprobe_zoffset */ ;
z2 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y)) /* + zprobe_zoffset */ ;
z3 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y)) /* + zprobe_zoffset */ ;
do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y)));
tilt_mesh_based_on_3pts(z1, z2, z3);
restore_ubl_active_state_and_leave();
}
}
if (parser.seen('P')) {
if (WITHIN(g29_phase_value, 0, 1) && state.storage_slot == -1) {
state.storage_slot = 0;
SERIAL_PROTOCOLLNPGM("Default storage slot 0 selected.");
}
switch (g29_phase_value) {
case 0:
//
// Zero Mesh Data
//
reset();
SERIAL_PROTOCOLLNPGM("Mesh zeroed.");
break;
case 1:
//
// Invalidate Entire Mesh and Automatically Probe Mesh in areas that can be reached by the probe
//
if (!parser.seen('C')) {
invalidate();
SERIAL_PROTOCOLLNPGM("Mesh invalidated. Probing mesh.");
}
if (g29_verbose_level > 1) {
SERIAL_PROTOCOLPAIR("Probing Mesh Points Closest to (", g29_x_pos);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL(g29_y_pos);
SERIAL_PROTOCOLLNPGM(").\n");
}
probe_entire_mesh(g29_x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, g29_y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER,
parser.seen('T'), parser.seen('E'), parser.seen('U'));
break;
case 2: {
#if ENABLED(NEWPANEL)
//
// Manually Probe Mesh in areas that can't be reached by the probe
//
SERIAL_PROTOCOLLNPGM("Manually probing unreachable mesh locations.");
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
if (!g29_x_flag && !g29_y_flag) {
/**
* Use a good default location for the path.
* The flipped > and < operators in these comparisons is intentional.
* It should cause the probed points to follow a nice path on Cartesian printers.
* It may make sense to have Delta printers default to the center of the bed.
* Until that is decided, this can be forced with the X and Y parameters.
*/
#if IS_KINEMATIC
g29_x_pos = X_HOME_POS;
g29_y_pos = Y_HOME_POS;
#else // cartesian
g29_x_pos = X_PROBE_OFFSET_FROM_EXTRUDER > 0 ? X_MAX_POS : X_MIN_POS;
g29_y_pos = Y_PROBE_OFFSET_FROM_EXTRUDER < 0 ? Y_MAX_POS : Y_MIN_POS;
#endif
}
if (parser.seen('C')) {
g29_x_pos = current_position[X_AXIS];
g29_y_pos = current_position[Y_AXIS];
}
if (parser.seen('B')) {
g29_card_thickness = parser.has_value() ? parser.value_float() : measure_business_card_thickness(Z_CLEARANCE_BETWEEN_PROBES);
if (FABS(g29_card_thickness) > 1.5) {
SERIAL_PROTOCOLLNPGM("?Error in Business Card measurement.");
return;
}
}
if (!position_is_reachable_xy(g29_x_pos, g29_y_pos)) {
SERIAL_PROTOCOLLNPGM("XY outside printable radius.");
return;
}
const float height = parser.floatval('H', Z_CLEARANCE_BETWEEN_PROBES);
manually_probe_remaining_mesh(g29_x_pos, g29_y_pos, height, g29_card_thickness, parser.seen('T'));
SERIAL_PROTOCOLLNPGM("G29 P2 finished.");
#else
SERIAL_PROTOCOLLNPGM("?P2 is only available when an LCD is present.");
return;
#endif
} break;
case 3: {
/**
* Populate invalid mesh areas. Proceed with caution.
* Two choices are available:
* - Specify a constant with the 'C' parameter.
* - Allow 'G29 P3' to choose a 'reasonable' constant.
*/
if (g29_c_flag) {
if (g29_repetition_cnt >= GRID_MAX_POINTS) {
set_all_mesh_points_to_value(g29_constant);
}
else {
while (g29_repetition_cnt--) { // this only populates reachable mesh points near
const mesh_index_pair location = find_closest_mesh_point_of_type(INVALID, g29_x_pos, g29_y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false);
if (location.x_index < 0) {
// No more REACHABLE INVALID mesh points to populate, so we ASSUME
// user meant to populate ALL INVALID mesh points to value
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (isnan(z_values[x][y]))
z_values[x][y] = g29_constant;
break; // No more invalid Mesh Points to populate
}
z_values[location.x_index][location.y_index] = g29_constant;
}
}
}
else {
const float cvf = parser.value_float();
switch((int)truncf(cvf * 10.0) - 30) { // 3.1 -> 1
#if ENABLED(UBL_G29_P31)
case 1: {
// P3.1 use least squares fit to fill missing mesh values
// P3.10 zero weighting for distance, all grid points equal, best fit tilted plane
// P3.11 10X weighting for nearest grid points versus farthest grid points
// P3.12 100X distance weighting
// P3.13 1000X distance weighting, approaches simple average of nearest points
const float weight_power = (cvf - 3.10) * 100.0, // 3.12345 -> 2.345
weight_factor = weight_power ? POW(10.0, weight_power) : 0;
smart_fill_wlsf(weight_factor);
}
break;
#endif
case 0: // P3 or P3.0
default: // and anything P3.x that's not P3.1
smart_fill_mesh(); // Do a 'Smart' fill using nearby known values
break;
}
}
break;
}
case 4: // Fine Tune (i.e., Edit) the Mesh
#if ENABLED(NEWPANEL)
fine_tune_mesh(g29_x_pos, g29_y_pos, parser.seen('T'));
#else
SERIAL_PROTOCOLLNPGM("?P4 is only available when an LCD is present.");
return;
#endif
break;
case 5: find_mean_mesh_height(); break;
case 6: shift_mesh_height(); break;
}
}
//
// Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
// good to have the extra information. Soon... we prune this to just a few items
//
if (parser.seen('W')) g29_what_command();
//
// When we are fully debugged, this may go away. But there are some valid
// use cases for the users. So we can wait and see what to do with it.
//
if (parser.seen('K')) // Kompare Current Mesh Data to Specified Stored Mesh
g29_compare_current_mesh_to_stored_mesh();
//
// Load a Mesh from the EEPROM
//
if (parser.seen('L')) { // Load Current Mesh Data
g29_storage_slot = parser.has_value() ? parser.value_int() : state.storage_slot;
int16_t a = settings.calc_num_meshes();
if (!a) {
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available.");
return;
}
if (!WITHIN(g29_storage_slot, 0, a - 1)) {
SERIAL_PROTOCOLLNPGM("?Invalid storage slot.");
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
return;
}
settings.load_mesh(g29_storage_slot);
state.storage_slot = g29_storage_slot;
SERIAL_PROTOCOLLNPGM("Done.");
}
//
// Store a Mesh in the EEPROM
//
if (parser.seen('S')) { // Store (or Save) Current Mesh Data
g29_storage_slot = parser.has_value() ? parser.value_int() : state.storage_slot;
if (g29_storage_slot == -1) { // Special case, we are going to 'Export' the mesh to the
SERIAL_ECHOLNPGM("G29 I 999"); // host in a form it can be reconstructed on a different machine
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(z_values[x][y])) {
SERIAL_ECHOPAIR("M421 I ", x);
SERIAL_ECHOPAIR(" J ", y);
SERIAL_ECHOPGM(" Z ");
SERIAL_ECHO_F(z_values[x][y], 6);
SERIAL_ECHOPAIR(" ; X ", LOGICAL_X_POSITION(mesh_index_to_xpos(x)));
SERIAL_ECHOPAIR(", Y ", LOGICAL_Y_POSITION(mesh_index_to_ypos(y)));
SERIAL_EOL();
}
return;
}
int16_t a = settings.calc_num_meshes();
if (!a) {
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available.");
goto LEAVE;
}
if (!WITHIN(g29_storage_slot, 0, a - 1)) {
SERIAL_PROTOCOLLNPGM("?Invalid storage slot.");
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
goto LEAVE;
}
settings.store_mesh(g29_storage_slot);
state.storage_slot = g29_storage_slot;
SERIAL_PROTOCOLLNPGM("Done.");
}
if (parser.seen('T'))
display_map(parser.has_value() ? parser.value_int() : 0);
/**
* This code may not be needed... Prepare for its removal...
*
*/
#if 0
if (parser.seen('Z')) {
if (parser.has_value())
state.z_offset = parser.value_float(); // do the simple case. Just lock in the specified value
else {
save_ubl_active_state_and_disable();
//float measured_z = probe_pt(g29_x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, g29_y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
has_control_of_lcd_panel = true; // Grab the LCD Hardware
float measured_z = 1.5;
do_blocking_move_to_z(measured_z); // Get close to the bed, but leave some space so we don't damage anything
// The user is not going to be locking in a new Z-Offset very often so
// it won't be that painful to spin the Encoder Wheel for 1.5mm
lcd_refresh();
lcd_z_offset_edit_setup(measured_z);
KEEPALIVE_STATE(PAUSED_FOR_USER);
do {
measured_z = lcd_z_offset_edit();
idle();
do_blocking_move_to_z(measured_z);
} while (!ubl_lcd_clicked());
has_control_of_lcd_panel = true; // There is a race condition for the encoder click.
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
// or here. So, until we are done looking for a long encoder press,
// we need to take control of the panel
KEEPALIVE_STATE(IN_HANDLER);
lcd_return_to_status();
const millis_t nxt = millis() + 1500UL;
while (ubl_lcd_clicked()) { // debounce and watch for abort
idle();
if (ELAPSED(millis(), nxt)) {
SERIAL_PROTOCOLLNPGM("\nZ-Offset Adjustment Stopped.");
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
LCD_MESSAGEPGM(MSG_UBL_Z_OFFSET_STOPPED);
restore_ubl_active_state_and_leave();
goto LEAVE;
}
}
has_control_of_lcd_panel = false;
safe_delay(20); // We don't want any switch noise.
state.z_offset = measured_z;
lcd_refresh();
restore_ubl_active_state_and_leave();
}
}
#endif
LEAVE:
#if ENABLED(NEWPANEL)
lcd_reset_alert_level();
LCD_MESSAGEPGM("");
lcd_quick_feedback();
has_control_of_lcd_panel = false;
#endif
return;
}
void unified_bed_leveling::find_mean_mesh_height() {
float sum = 0.0;
int n = 0;
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(z_values[x][y])) {
sum += z_values[x][y];
n++;
}
const float mean = sum / n;
//
// Sum the squares of difference from mean
//
float sum_of_diff_squared = 0.0;
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(z_values[x][y]))
sum_of_diff_squared += sq(z_values[x][y] - mean);
SERIAL_ECHOLNPAIR("# of samples: ", n);
SERIAL_ECHOPGM("Mean Mesh Height: ");
SERIAL_ECHO_F(mean, 6);
SERIAL_EOL();
const float sigma = SQRT(sum_of_diff_squared / (n + 1));
SERIAL_ECHOPGM("Standard Deviation: ");
SERIAL_ECHO_F(sigma, 6);
SERIAL_EOL();
if (g29_c_flag)
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(z_values[x][y]))
z_values[x][y] -= mean + g29_constant;
}
void unified_bed_leveling::shift_mesh_height() {
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(z_values[x][y]))
z_values[x][y] += g29_constant;
}
/**
* Probe all invalidated locations of the mesh that can be reached by the probe.
* This attempts to fill in locations closest to the nozzle's start location first.
*/
void unified_bed_leveling::probe_entire_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map, const bool stow_probe, bool close_or_far) {
mesh_index_pair location;
has_control_of_lcd_panel = true;
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
DEPLOY_PROBE();
uint16_t max_iterations = GRID_MAX_POINTS;
do {
#if ENABLED(NEWPANEL)
if (ubl_lcd_clicked()) {
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.\n");
lcd_quick_feedback();
STOW_PROBE();
while (ubl_lcd_clicked()) idle();
has_control_of_lcd_panel = false;
restore_ubl_active_state_and_leave();
safe_delay(50); // Debounce the Encoder wheel
return;
}
#endif
location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_PROBE_AS_REFERENCE, NULL, close_or_far);
if (location.x_index >= 0) { // mesh point found and is reachable by probe
const float rawx = mesh_index_to_xpos(location.x_index),
rawy = mesh_index_to_ypos(location.y_index);
const float measured_z = probe_pt(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy), stow_probe, g29_verbose_level); // TODO: Needs error handling
z_values[location.x_index][location.y_index] = measured_z;
}
if (do_ubl_mesh_map) display_map(g29_map_type);
} while (location.x_index >= 0 && --max_iterations);
STOW_PROBE();
restore_ubl_active_state_and_leave();
do_blocking_move_to_xy(
constrain(lx - (X_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_X, UBL_MESH_MAX_X),
constrain(ly - (Y_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_Y, UBL_MESH_MAX_Y)
);
}
void unified_bed_leveling::tilt_mesh_based_on_3pts(const float &z1, const float &z2, const float &z3) {
matrix_3x3 rotation;
vector_3 v1 = vector_3( (UBL_PROBE_PT_1_X - UBL_PROBE_PT_2_X),
(UBL_PROBE_PT_1_Y - UBL_PROBE_PT_2_Y),
(z1 - z2) ),
v2 = vector_3( (UBL_PROBE_PT_3_X - UBL_PROBE_PT_2_X),
(UBL_PROBE_PT_3_Y - UBL_PROBE_PT_2_Y),
(z3 - z2) ),
normal = vector_3::cross(v1, v2);
normal = normal.get_normal();
/**
* This vector is normal to the tilted plane.
* However, we don't know its direction. We need it to point up. So if
* Z is negative, we need to invert the sign of all components of the vector
*/
if (normal.z < 0.0) {
normal.x = -normal.x;
normal.y = -normal.y;
normal.z = -normal.z;
}
rotation = matrix_3x3::create_look_at(vector_3(normal.x, normal.y, 1));
if (g29_verbose_level > 2) {
SERIAL_ECHOPGM("bed plane normal = [");
SERIAL_PROTOCOL_F(normal.x, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.y, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.z, 7);
SERIAL_ECHOLNPGM("]");
rotation.debug(PSTR("rotation matrix:"));
}
//
// All of 3 of these points should give us the same d constant
//
float t = normal.x * (UBL_PROBE_PT_1_X) + normal.y * (UBL_PROBE_PT_1_Y),
d = t + normal.z * z1;
if (g29_verbose_level>2) {
SERIAL_ECHOPGM("D constant: ");
SERIAL_PROTOCOL_F(d, 7);
SERIAL_ECHOLNPGM(" ");
}
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("d from 1st point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_EOL();
t = normal.x * (UBL_PROBE_PT_2_X) + normal.y * (UBL_PROBE_PT_2_Y);
d = t + normal.z * z2;
SERIAL_ECHOPGM("d from 2nd point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_EOL();
t = normal.x * (UBL_PROBE_PT_3_X) + normal.y * (UBL_PROBE_PT_3_Y);
d = t + normal.z * z3;
SERIAL_ECHOPGM("d from 3rd point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_EOL();
}
#endif
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
float x_tmp = mesh_index_to_xpos(i),
y_tmp = mesh_index_to_ypos(j),
z_tmp = z_values[i][j];
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("before rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOPGM("] ---> ");
safe_delay(20);
}
#endif
apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp);
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("after rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOLNPGM("]");
safe_delay(55);
}
#endif
z_values[i][j] += z_tmp - d;
}
}
}
#if ENABLED(NEWPANEL)
float unified_bed_leveling::measure_point_with_encoder() {
while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel
delay(50); // debounce
KEEPALIVE_STATE(PAUSED_FOR_USER);
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
idle();
if (encoder_diff) {
do_blocking_move_to_z(current_position[Z_AXIS] + 0.01 * float(encoder_diff));
encoder_diff = 0;
}
}
KEEPALIVE_STATE(IN_HANDLER);
return current_position[Z_AXIS];
}
static void echo_and_take_a_measurement() { SERIAL_PROTOCOLLNPGM(" and take a measurement."); }
float unified_bed_leveling::measure_business_card_thickness(float in_height) {
has_control_of_lcd_panel = true;
save_ubl_active_state_and_disable(); // Disable bed level correction for probing
do_blocking_move_to_z(in_height);
do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y)));
//, min(planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS]) / 2.0);
stepper.synchronize();
SERIAL_PROTOCOLPGM("Place shim under nozzle");
LCD_MESSAGEPGM(MSG_UBL_BC_INSERT);
lcd_return_to_status();
echo_and_take_a_measurement();
const float z1 = measure_point_with_encoder();
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
stepper.synchronize();
SERIAL_PROTOCOLPGM("Remove shim");
LCD_MESSAGEPGM(MSG_UBL_BC_REMOVE);
echo_and_take_a_measurement();
const float z2 = measure_point_with_encoder();
do_blocking_move_to_z(current_position[Z_AXIS] + Z_CLEARANCE_BETWEEN_PROBES);
const float thickness = abs(z1 - z2);
if (g29_verbose_level > 1) {
SERIAL_PROTOCOLPGM("Business Card is ");
SERIAL_PROTOCOL_F(thickness, 4);
SERIAL_PROTOCOLLNPGM("mm thick.");
}
in_height = current_position[Z_AXIS]; // do manual probing at lower height
has_control_of_lcd_panel = false;
restore_ubl_active_state_and_leave();
return thickness;
}
void unified_bed_leveling::manually_probe_remaining_mesh(const float &lx, const float &ly, const float &z_clearance, const float &thick, const bool do_ubl_mesh_map) {
has_control_of_lcd_panel = true;
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
do_blocking_move_to_xy(lx, ly);
lcd_return_to_status();
mesh_index_pair location;
do {
location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_NOZZLE_AS_REFERENCE, NULL, false);
// It doesn't matter if the probe can't reach the NAN location. This is a manual probe.
if (location.x_index < 0 && location.y_index < 0) continue;
const float rawx = mesh_index_to_xpos(location.x_index),
rawy = mesh_index_to_ypos(location.y_index),
xProbe = LOGICAL_X_POSITION(rawx),
yProbe = LOGICAL_Y_POSITION(rawy);
if (!position_is_reachable_raw_xy(rawx, rawy)) break; // SHOULD NOT OCCUR (find_closest_mesh_point only returns reachable points)
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
LCD_MESSAGEPGM(MSG_UBL_MOVING_TO_NEXT);
do_blocking_move_to_xy(xProbe, yProbe);
do_blocking_move_to_z(z_clearance);
KEEPALIVE_STATE(PAUSED_FOR_USER);
has_control_of_lcd_panel = true;
if (do_ubl_mesh_map) display_map(g29_map_type); // show user where we're probing
serialprintPGM(parser.seen('B') ? PSTR(MSG_UBL_BC_INSERT) : PSTR(MSG_UBL_BC_INSERT2));
const float z_step = 0.01; // existing behavior: 0.01mm per click, occasionally step
//const float z_step = 1.0 / planner.axis_steps_per_mm[Z_AXIS]; // approx one step each click
while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel
delay(50); // debounce
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
idle();
if (encoder_diff) {
do_blocking_move_to_z(current_position[Z_AXIS] + float(encoder_diff) * z_step);
encoder_diff = 0;
}
}
// this sequence to detect an ubl_lcd_clicked() debounce it and leave if it is
// a Press and Hold is repeated in a lot of places (including G26_Mesh_Validation.cpp). This
// should be redone and compressed.
const millis_t nxt = millis() + 1500L;
while (ubl_lcd_clicked()) { // debounce and watch for abort
idle();
if (ELAPSED(millis(), nxt)) {
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.");
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
#if ENABLED(NEWPANEL)
lcd_quick_feedback();
while (ubl_lcd_clicked()) idle();
has_control_of_lcd_panel = false;
#endif
KEEPALIVE_STATE(IN_HANDLER);
restore_ubl_active_state_and_leave();
return;
}
}
z_values[location.x_index][location.y_index] = current_position[Z_AXIS] - thick;
if (g29_verbose_level > 2) {
SERIAL_PROTOCOLPGM("Mesh Point Measured at: ");
SERIAL_PROTOCOL_F(z_values[location.x_index][location.y_index], 6);
SERIAL_EOL();
}
} while (location.x_index >= 0 && location.y_index >= 0);
if (do_ubl_mesh_map) display_map(g29_map_type);
restore_ubl_active_state_and_leave();
KEEPALIVE_STATE(IN_HANDLER);
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
do_blocking_move_to_xy(lx, ly);
}
#endif
bool unified_bed_leveling::g29_parameter_parsing() {
bool err_flag = false;
#if ENABLED(NEWPANEL)
LCD_MESSAGEPGM(MSG_UBL_DOING_G29);
lcd_quick_feedback();
#endif
g29_constant = 0.0;
g29_repetition_cnt = 0;
g29_x_flag = parser.seenval('X');
g29_x_pos = g29_x_flag ? parser.value_float() : current_position[X_AXIS];
g29_y_flag = parser.seenval('Y');
g29_y_pos = g29_y_flag ? parser.value_float() : current_position[Y_AXIS];
if (parser.seen('R')) {
g29_repetition_cnt = parser.has_value() ? parser.value_int() : GRID_MAX_POINTS;
NOMORE(g29_repetition_cnt, GRID_MAX_POINTS);
if (g29_repetition_cnt < 1) {
SERIAL_PROTOCOLLNPGM("?(R)epetition count invalid (1+).\n");
return UBL_ERR;
}
}
g29_verbose_level = parser.seen('V') ? parser.value_int() : 0;
if (!WITHIN(g29_verbose_level, 0, 4)) {
SERIAL_PROTOCOLLNPGM("?(V)erbose level is implausible (0-4).\n");
err_flag = true;
}
if (parser.seen('P')) {
g29_phase_value = parser.value_int();
if (!WITHIN(g29_phase_value, 0, 6)) {
SERIAL_PROTOCOLLNPGM("?(P)hase value invalid (0-6).\n");
err_flag = true;
}
}
if (parser.seen('J')) {
g29_grid_size = parser.has_value() ? parser.value_int() : 0;
if (g29_grid_size && !WITHIN(g29_grid_size, 2, 9)) {
SERIAL_PROTOCOLLNPGM("?Invalid grid size (J) specified (2-9).\n");
err_flag = true;
}
}
if (g29_x_flag != g29_y_flag) {
SERIAL_PROTOCOLLNPGM("Both X & Y locations must be specified.\n");
err_flag = true;
}
if (!WITHIN(RAW_X_POSITION(g29_x_pos), X_MIN_POS, X_MAX_POS)) {
SERIAL_PROTOCOLLNPGM("Invalid X location specified.\n");
err_flag = true;
}
if (!WITHIN(RAW_Y_POSITION(g29_y_pos), Y_MIN_POS, Y_MAX_POS)) {
SERIAL_PROTOCOLLNPGM("Invalid Y location specified.\n");
err_flag = true;
}
if (err_flag) return UBL_ERR;
/**
* Activate or deactivate UBL
* Note: UBL's G29 restores the state set here when done.
* Leveling is being enabled here with old data, possibly
* none. Error handling should disable for safety...
*/
if (parser.seen('A')) {
if (parser.seen('D')) {
SERIAL_PROTOCOLLNPGM("?Can't activate and deactivate at the same time.\n");
return UBL_ERR;
}
set_bed_leveling_enabled(true);
report_state();
}
else if (parser.seen('D')) {
set_bed_leveling_enabled(false);
report_state();
}
// Set global 'C' flag and its value
if ((g29_c_flag = parser.seen('C')))
g29_constant = parser.value_float();
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
if (parser.seenval('F')) {
const float fh = parser.value_float();
if (!WITHIN(fh, 0.0, 100.0)) {
SERIAL_PROTOCOLLNPGM("?(F)ade height for Bed Level Correction not plausible.\n");
return UBL_ERR;
}
set_z_fade_height(fh);
}
#endif
g29_map_type = parser.intval('T');
if (!WITHIN(g29_map_type, 0, 2)) {
SERIAL_PROTOCOLLNPGM("Invalid map type.\n");
return UBL_ERR;
}
return UBL_OK;
}
static int ubl_state_at_invocation = 0,
ubl_state_recursion_chk = 0;
void unified_bed_leveling::save_ubl_active_state_and_disable() {
ubl_state_recursion_chk++;
if (ubl_state_recursion_chk != 1) {
SERIAL_ECHOLNPGM("save_ubl_active_state_and_disabled() called multiple times in a row.");
#if ENABLED(NEWPANEL)
LCD_MESSAGEPGM(MSG_UBL_SAVE_ERROR);
lcd_quick_feedback();
#endif
return;
}
ubl_state_at_invocation = state.active;
set_bed_leveling_enabled(false);
}
void unified_bed_leveling::restore_ubl_active_state_and_leave() {
if (--ubl_state_recursion_chk) {
SERIAL_ECHOLNPGM("restore_ubl_active_state_and_leave() called too many times.");
#if ENABLED(NEWPANEL)
LCD_MESSAGEPGM(MSG_UBL_RESTORE_ERROR);
lcd_quick_feedback();
#endif
return;
}
set_bed_leveling_enabled(ubl_state_at_invocation);
}
/**
* Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
* good to have the extra information. Soon... we prune this to just a few items
*/
void unified_bed_leveling::g29_what_command() {
report_state();
if (state.storage_slot == -1)
SERIAL_PROTOCOLPGM("No Mesh Loaded.");
else {
SERIAL_PROTOCOLPAIR("Mesh ", state.storage_slot);
SERIAL_PROTOCOLPGM(" Loaded.");
}
SERIAL_EOL();
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("UBL object count: ", (int)ubl_cnt);
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
SERIAL_PROTOCOL("planner.z_fade_height : ");
SERIAL_PROTOCOL_F(planner.z_fade_height, 4);
SERIAL_EOL();
#endif
#if HAS_BED_PROBE
SERIAL_PROTOCOLPGM("zprobe_zoffset: ");
SERIAL_PROTOCOL_F(zprobe_zoffset, 7);
SERIAL_EOL();
#endif
SERIAL_ECHOLNPAIR("UBL_MESH_MIN_X " STRINGIFY(UBL_MESH_MIN_X) "=", UBL_MESH_MIN_X);
SERIAL_ECHOLNPAIR("UBL_MESH_MIN_Y " STRINGIFY(UBL_MESH_MIN_Y) "=", UBL_MESH_MIN_Y);
safe_delay(25);
SERIAL_ECHOLNPAIR("UBL_MESH_MAX_X " STRINGIFY(UBL_MESH_MAX_X) "=", UBL_MESH_MAX_X);
SERIAL_ECHOLNPAIR("UBL_MESH_MAX_Y " STRINGIFY(UBL_MESH_MAX_Y) "=", UBL_MESH_MAX_Y);
safe_delay(25);
SERIAL_ECHOLNPAIR("GRID_MAX_POINTS_X ", GRID_MAX_POINTS_X);
SERIAL_ECHOLNPAIR("GRID_MAX_POINTS_Y ", GRID_MAX_POINTS_Y);
safe_delay(25);
SERIAL_ECHOLNPAIR("MESH_X_DIST ", MESH_X_DIST);
SERIAL_ECHOLNPAIR("MESH_Y_DIST ", MESH_Y_DIST);
safe_delay(25);
SERIAL_PROTOCOLPGM("X-Axis Mesh Points at: ");
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(mesh_index_to_xpos(i)), 3);
SERIAL_PROTOCOLPGM(" ");
safe_delay(25);
}
SERIAL_EOL();
SERIAL_PROTOCOLPGM("Y-Axis Mesh Points at: ");
for (uint8_t i = 0; i < GRID_MAX_POINTS_Y; i++) {
SERIAL_PROTOCOL_F(LOGICAL_Y_POSITION(mesh_index_to_ypos(i)), 3);
SERIAL_PROTOCOLPGM(" ");
safe_delay(25);
}
SERIAL_EOL();
#if HAS_KILL
SERIAL_PROTOCOLPAIR("Kill pin on :", KILL_PIN);
SERIAL_PROTOCOLLNPAIR(" state:", READ(KILL_PIN));
#endif
SERIAL_EOL();
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("ubl_state_at_invocation :", ubl_state_at_invocation);
SERIAL_EOL();
SERIAL_PROTOCOLLNPAIR("ubl_state_recursion_chk :", ubl_state_recursion_chk);
SERIAL_EOL();
safe_delay(50);
SERIAL_PROTOCOLPAIR("Meshes go from ", hex_address((void*)settings.get_start_of_meshes()));
SERIAL_PROTOCOLLNPAIR(" to ", hex_address((void*)settings.get_end_of_meshes()));
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("sizeof(ubl) : ", (int)sizeof(ubl));
SERIAL_EOL();
SERIAL_PROTOCOLLNPAIR("z_value[][] size: ", (int)sizeof(z_values));
SERIAL_EOL();
safe_delay(25);
SERIAL_PROTOCOLLNPAIR("EEPROM free for UBL: ", hex_address((void*)(settings.get_end_of_meshes() - settings.get_start_of_meshes())));
safe_delay(50);
SERIAL_PROTOCOLPAIR("EEPROM can hold ", settings.calc_num_meshes());
SERIAL_PROTOCOLLNPGM(" meshes.\n");
safe_delay(25);
if (!sanity_check()) {
echo_name();
SERIAL_PROTOCOLLNPGM(" sanity checks passed.");
}
}
/**
* When we are fully debugged, the EEPROM dump command will get deleted also. But
* right now, it is good to have the extra information. Soon... we prune this.
*/
void unified_bed_leveling::g29_eeprom_dump() {
unsigned char cccc;
uint16_t kkkk;
SERIAL_ECHO_START();
SERIAL_ECHOLNPGM("EEPROM Dump:");
for (uint16_t i = 0; i < E2END + 1; i += 16) {
if (!(i & 0x3)) idle();
print_hex_word(i);
SERIAL_ECHOPGM(": ");
for (uint16_t j = 0; j < 16; j++) {
kkkk = i + j;
eeprom_read_block(&cccc, (void *)kkkk, 1);
print_hex_byte(cccc);
SERIAL_ECHO(' ');
}
SERIAL_EOL();
}
SERIAL_EOL();
}
/**
* When we are fully debugged, this may go away. But there are some valid
* use cases for the users. So we can wait and see what to do with it.
*/
void unified_bed_leveling::g29_compare_current_mesh_to_stored_mesh() {
int16_t a = settings.calc_num_meshes();
if (!a) {
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available.");
return;
}
if (!parser.has_value()) {
SERIAL_PROTOCOLLNPGM("?Storage slot # required.");
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
return;
}
g29_storage_slot = parser.value_int();
if (!WITHIN(g29_storage_slot, 0, a - 1)) {
SERIAL_PROTOCOLLNPGM("?Invalid storage slot.");
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
return;
}
float tmp_z_values[GRID_MAX_POINTS_X][GRID_MAX_POINTS_Y];
settings.load_mesh(g29_storage_slot, &tmp_z_values);
SERIAL_PROTOCOLPAIR("Subtracting mesh in slot ", g29_storage_slot);
SERIAL_PROTOCOLLNPGM(" from current mesh.");
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
z_values[x][y] -= tmp_z_values[x][y];
}
mesh_index_pair unified_bed_leveling::find_closest_mesh_point_of_type(const MeshPointType type, const float &lx, const float &ly, const bool probe_as_reference, unsigned int bits[16], const bool far_flag) {
mesh_index_pair out_mesh;
out_mesh.x_index = out_mesh.y_index = -1;
// Get our reference position. Either the nozzle or probe location.
const float px = RAW_X_POSITION(lx) - (probe_as_reference == USE_PROBE_AS_REFERENCE ? X_PROBE_OFFSET_FROM_EXTRUDER : 0),
py = RAW_Y_POSITION(ly) - (probe_as_reference == USE_PROBE_AS_REFERENCE ? Y_PROBE_OFFSET_FROM_EXTRUDER : 0);
float best_so_far = far_flag ? -99999.99 : 99999.99;
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
if ( (type == INVALID && isnan(z_values[i][j])) // Check to see if this location holds the right thing
|| (type == REAL && !isnan(z_values[i][j]))
|| (type == SET_IN_BITMAP && is_bit_set(bits, i, j))
) {
// We only get here if we found a Mesh Point of the specified type
float raw_x = RAW_CURRENT_POSITION(X), raw_y = RAW_CURRENT_POSITION(Y);
const float mx = mesh_index_to_xpos(i),
my = mesh_index_to_ypos(j);
// If using the probe as the reference there are some unreachable locations.
// Also for round beds, there are grid points outside the bed the nozzle can't reach.
// Prune them from the list and ignore them till the next Phase (manual nozzle probing).
if (probe_as_reference ? !position_is_reachable_by_probe_raw_xy(mx, my) : !position_is_reachable_raw_xy(mx, my))
continue;
// Reachable. Check if it's the best_so_far location to the nozzle.
// Add in a weighting factor that considers the current location of the nozzle.
float distance = HYPOT(px - mx, py - my);
/**
* If doing the far_flag action, we want to be as far as possible
* from the starting point and from any other probed points. We
* want the next point spread out and filling in any blank spaces
* in the mesh. So we add in some of the distance to every probed
* point we can find.
*/
if (far_flag) {
for (uint8_t k = 0; k < GRID_MAX_POINTS_X; k++) {
for (uint8_t l = 0; l < GRID_MAX_POINTS_Y; l++) {
if (i != k && j != l && !isnan(z_values[k][l])) {
//distance += pow((float) abs(i - k) * (MESH_X_DIST), 2) + pow((float) abs(j - l) * (MESH_Y_DIST), 2); // working here
distance += HYPOT(MESH_X_DIST, MESH_Y_DIST) / log(HYPOT((i - k) * (MESH_X_DIST) + .001, (j - l) * (MESH_Y_DIST)) + .001);
}
}
}
}
else
// factor in the distance from the current location for the normal case
// so the nozzle isn't running all over the bed.
distance += HYPOT(raw_x - mx, raw_y - my) * 0.1;
// if far_flag, look for farthest point
if (far_flag == (distance > best_so_far) && distance != best_so_far) {
best_so_far = distance; // We found a closer/farther location with
out_mesh.x_index = i; // the specified type of mesh value.
out_mesh.y_index = j;
out_mesh.distance = best_so_far;
}
}
} // for j
} // for i
return out_mesh;
}
#if ENABLED(NEWPANEL)
void unified_bed_leveling::fine_tune_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map) {
if (!parser.seen('R')) // fine_tune_mesh() is special. If no repetition count flag is specified
g29_repetition_cnt = 1; // do exactly one mesh location. Otherwise use what the parser decided.
#if ENABLED(UBL_MESH_EDIT_MOVES_Z)
const bool is_offset = parser.seen('H');
const float h_offset = is_offset ? parser.value_linear_units() : Z_CLEARANCE_BETWEEN_PROBES;
if (is_offset && !WITHIN(h_offset, 0, 10)) {
SERIAL_PROTOCOLLNPGM("Offset out of bounds. (0 to 10mm)\n");
return;
}
#endif
mesh_index_pair location;
if (!position_is_reachable_xy(lx, ly)) {
SERIAL_PROTOCOLLNPGM("(X,Y) outside printable radius.");
return;
}
save_ubl_active_state_and_disable();
LCD_MESSAGEPGM(MSG_UBL_FINE_TUNE_MESH);
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
do_blocking_move_to_xy(lx, ly);
uint16_t not_done[16];
memset(not_done, 0xFF, sizeof(not_done));
do {
location = find_closest_mesh_point_of_type(SET_IN_BITMAP, lx, ly, USE_NOZZLE_AS_REFERENCE, not_done, false);
if (location.x_index < 0) break; // stop when we can't find any more reachable points.
bit_clear(not_done, location.x_index, location.y_index); // Mark this location as 'adjusted' so we will find a
// different location the next time through the loop
const float rawx = mesh_index_to_xpos(location.x_index),
rawy = mesh_index_to_ypos(location.y_index);
if (!position_is_reachable_raw_xy(rawx, rawy)) // SHOULD NOT OCCUR because find_closest_mesh_point_of_type will only return reachable
break;
float new_z = z_values[location.x_index][location.y_index];
if (isnan(new_z)) // if the mesh point is invalid, set it to 0.0 so it can be edited
new_z = 0.0;
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); // Move the nozzle to where we are going to edit
do_blocking_move_to_xy(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy));
new_z = FLOOR(new_z * 1000.0) * 0.001; // Chop off digits after the 1000ths place
KEEPALIVE_STATE(PAUSED_FOR_USER);
has_control_of_lcd_panel = true;
if (do_ubl_mesh_map) display_map(g29_map_type); // show the user which point is being adjusted
lcd_refresh();
lcd_mesh_edit_setup(new_z);
do {
new_z = lcd_mesh_edit();
#if ENABLED(UBL_MESH_EDIT_MOVES_Z)
do_blocking_move_to_z(h_offset + new_z); // Move the nozzle as the point is edited
#endif
idle();
} while (!ubl_lcd_clicked());
if (!ubl_lcd_map_control) lcd_return_to_status();
// The technique used here generates a race condition for the encoder click.
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune) or here.
// Let's work on specifying a proper API for the LCD ASAP, OK?
has_control_of_lcd_panel = true;
// this sequence to detect an ubl_lcd_clicked() debounce it and leave if it is
// a Press and Hold is repeated in a lot of places (including G26_Mesh_Validation.cpp). This
// should be redone and compressed.
const millis_t nxt = millis() + 1500UL;
while (ubl_lcd_clicked()) { // debounce and watch for abort
idle();
if (ELAPSED(millis(), nxt)) {
ubl_lcd_map_control = false;
lcd_return_to_status();
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
LCD_MESSAGEPGM(MSG_EDITING_STOPPED);
while (ubl_lcd_clicked()) idle();
goto FINE_TUNE_EXIT;
}
}
safe_delay(20); // We don't want any switch noise.
z_values[location.x_index][location.y_index] = new_z;
lcd_refresh();
} while (location.x_index >= 0 && --g29_repetition_cnt > 0);
FINE_TUNE_EXIT:
has_control_of_lcd_panel = false;
KEEPALIVE_STATE(IN_HANDLER);
if (do_ubl_mesh_map) display_map(g29_map_type);
restore_ubl_active_state_and_leave();
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
do_blocking_move_to_xy(lx, ly);
LCD_MESSAGEPGM(MSG_UBL_DONE_EDITING_MESH);
SERIAL_ECHOLNPGM("Done Editing Mesh");
if (ubl_lcd_map_control)
lcd_goto_screen(_lcd_ubl_output_map_lcd);
else
lcd_return_to_status();
}
#endif // NEWPANEL
/**
* 'Smart Fill': Scan from the outward edges of the mesh towards the center.
* If an invalid location is found, use the next two points (if valid) to
* calculate a 'reasonable' value for the unprobed mesh point.
*/
bool unified_bed_leveling::smart_fill_one(const uint8_t x, const uint8_t y, const int8_t xdir, const int8_t ydir) {
const int8_t x1 = x + xdir, x2 = x1 + xdir,
y1 = y + ydir, y2 = y1 + ydir;
// A NAN next to a pair of real values?
if (isnan(z_values[x][y]) && !isnan(z_values[x1][y1]) && !isnan(z_values[x2][y2])) {
if (z_values[x1][y1] < z_values[x2][y2]) // Angled downward?
z_values[x][y] = z_values[x1][y1]; // Use nearest (maybe a little too high.)
else
z_values[x][y] = 2.0 * z_values[x1][y1] - z_values[x2][y2]; // Angled upward...
return true;
}
return false;
}
typedef struct { uint8_t sx, ex, sy, ey; bool yfirst; } smart_fill_info;
void unified_bed_leveling::smart_fill_mesh() {
static const smart_fill_info
info0 PROGMEM = { 0, GRID_MAX_POINTS_X, 0, GRID_MAX_POINTS_Y - 2, false }, // Bottom of the mesh looking up
info1 PROGMEM = { 0, GRID_MAX_POINTS_X, GRID_MAX_POINTS_Y - 1, 0, false }, // Top of the mesh looking down
info2 PROGMEM = { 0, GRID_MAX_POINTS_X - 2, 0, GRID_MAX_POINTS_Y, true }, // Left side of the mesh looking right
info3 PROGMEM = { GRID_MAX_POINTS_X - 1, 0, 0, GRID_MAX_POINTS_Y, true }; // Right side of the mesh looking left
static const smart_fill_info * const info[] PROGMEM = { &info0, &info1, &info2, &info3 };
// static const smart_fill_info info[] PROGMEM = {
// { 0, GRID_MAX_POINTS_X, 0, GRID_MAX_POINTS_Y - 2, false } PROGMEM, // Bottom of the mesh looking up
// { 0, GRID_MAX_POINTS_X, GRID_MAX_POINTS_Y - 1, 0, false } PROGMEM, // Top of the mesh looking down
// { 0, GRID_MAX_POINTS_X - 2, 0, GRID_MAX_POINTS_Y, true } PROGMEM, // Left side of the mesh looking right
// { GRID_MAX_POINTS_X - 1, 0, 0, GRID_MAX_POINTS_Y, true } PROGMEM // Right side of the mesh looking left
// };
for (uint8_t i = 0; i < COUNT(info); ++i) {
const smart_fill_info *f = (smart_fill_info*)pgm_read_word(&info[i]);
const int8_t sx = pgm_read_word(&f->sx), sy = pgm_read_word(&f->sy),
ex = pgm_read_word(&f->ex), ey = pgm_read_word(&f->ey);
if (pgm_read_byte(&f->yfirst)) {
const int8_t dir = ex > sx ? 1 : -1;
for (uint8_t y = sy; y != ey; ++y)
for (uint8_t x = sx; x != ex; x += dir)
if (smart_fill_one(x, y, dir, 0)) break;
}
else {
const int8_t dir = ey > sy ? 1 : -1;
for (uint8_t x = sx; x != ex; ++x)
for (uint8_t y = sy; y != ey; y += dir)
if (smart_fill_one(x, y, 0, dir)) break;
}
}
}
void unified_bed_leveling::tilt_mesh_based_on_probed_grid(const bool do_ubl_mesh_map) {
constexpr int16_t x_min = max(MIN_PROBE_X, UBL_MESH_MIN_X),
x_max = min(MAX_PROBE_X, UBL_MESH_MAX_X),
y_min = max(MIN_PROBE_Y, UBL_MESH_MIN_Y),
y_max = min(MAX_PROBE_Y, UBL_MESH_MAX_Y);
const float dx = float(x_max - x_min) / (g29_grid_size - 1.0),
dy = float(y_max - y_min) / (g29_grid_size - 1.0);
struct linear_fit_data lsf_results;
incremental_LSF_reset(&lsf_results);
bool zig_zag = false;
for (uint8_t ix = 0; ix < g29_grid_size; ix++) {
const float x = float(x_min) + ix * dx;
for (int8_t iy = 0; iy < g29_grid_size; iy++) {
const float y = float(y_min) + dy * (zig_zag ? g29_grid_size - 1 - iy : iy);
float measured_z = probe_pt(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y), parser.seen('E'), g29_verbose_level); // TODO: Needs error handling
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_CHAR('(');
SERIAL_PROTOCOL_F(x, 7);
SERIAL_CHAR(',');
SERIAL_PROTOCOL_F(y, 7);
SERIAL_ECHOPGM(") logical: ");
SERIAL_CHAR('(');
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(x), 7);
SERIAL_CHAR(',');
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(y), 7);
SERIAL_ECHOPGM(") measured: ");
SERIAL_PROTOCOL_F(measured_z, 7);
SERIAL_ECHOPGM(" correction: ");
SERIAL_PROTOCOL_F(get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)), 7);
}
#endif
measured_z -= get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)) /* + zprobe_zoffset */ ;
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM(" final >>>---> ");
SERIAL_PROTOCOL_F(measured_z, 7);
SERIAL_EOL();
}
#endif
incremental_LSF(&lsf_results, x, y, measured_z);
}
zig_zag ^= true;
}
if (finish_incremental_LSF(&lsf_results)) {
SERIAL_ECHOPGM("Could not complete LSF!");
return;
}
if (g29_verbose_level > 3) {
SERIAL_ECHOPGM("LSF Results A=");
SERIAL_PROTOCOL_F(lsf_results.A, 7);
SERIAL_ECHOPGM(" B=");
SERIAL_PROTOCOL_F(lsf_results.B, 7);
SERIAL_ECHOPGM(" D=");
SERIAL_PROTOCOL_F(lsf_results.D, 7);
SERIAL_EOL();
}
vector_3 normal = vector_3(lsf_results.A, lsf_results.B, 1.0000).get_normal();
if (g29_verbose_level > 2) {
SERIAL_ECHOPGM("bed plane normal = [");
SERIAL_PROTOCOL_F(normal.x, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.y, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.z, 7);
SERIAL_ECHOLNPGM("]");
}
matrix_3x3 rotation = matrix_3x3::create_look_at(vector_3(lsf_results.A, lsf_results.B, 1));
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
float x_tmp = mesh_index_to_xpos(i),
y_tmp = mesh_index_to_ypos(j),
z_tmp = z_values[i][j];
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("before rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOPGM("] ---> ");
safe_delay(20);
}
#endif
apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp);
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("after rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOLNPGM("]");
safe_delay(55);
}
#endif
z_values[i][j] += z_tmp - lsf_results.D;
}
}
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
rotation.debug(PSTR("rotation matrix:"));
SERIAL_ECHOPGM("LSF Results A=");
SERIAL_PROTOCOL_F(lsf_results.A, 7);
SERIAL_ECHOPGM(" B=");
SERIAL_PROTOCOL_F(lsf_results.B, 7);
SERIAL_ECHOPGM(" D=");
SERIAL_PROTOCOL_F(lsf_results.D, 7);
SERIAL_EOL();
safe_delay(55);
SERIAL_ECHOPGM("bed plane normal = [");
SERIAL_PROTOCOL_F(normal.x, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.y, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.z, 7);
SERIAL_ECHOPGM("]\n");
SERIAL_EOL();
}
#endif
if (do_ubl_mesh_map) display_map(g29_map_type);
}
#if ENABLED(UBL_G29_P31)
void unified_bed_leveling::smart_fill_wlsf(const float &weight_factor) {
// For each undefined mesh point, compute a distance-weighted least squares fit
// from all the originally populated mesh points, weighted toward the point
// being extrapolated so that nearby points will have greater influence on
// the point being extrapolated. Then extrapolate the mesh point from WLSF.
static_assert(GRID_MAX_POINTS_Y <= 16, "GRID_MAX_POINTS_Y too big");
uint16_t bitmap[GRID_MAX_POINTS_X] = { 0 };
struct linear_fit_data lsf_results;
SERIAL_ECHOPGM("Extrapolating mesh...");
const float weight_scaled = weight_factor * max(MESH_X_DIST, MESH_Y_DIST);
for (uint8_t jx = 0; jx < GRID_MAX_POINTS_X; jx++)
for (uint8_t jy = 0; jy < GRID_MAX_POINTS_Y; jy++)
if (!isnan(z_values[jx][jy]))
SBI(bitmap[jx], jy);
for (uint8_t ix = 0; ix < GRID_MAX_POINTS_X; ix++) {
const float px = mesh_index_to_xpos(ix);
for (uint8_t iy = 0; iy < GRID_MAX_POINTS_Y; iy++) {
const float py = mesh_index_to_ypos(iy);
if (isnan(z_values[ix][iy])) {
// undefined mesh point at (px,py), compute weighted LSF from original valid mesh points.
incremental_LSF_reset(&lsf_results);
for (uint8_t jx = 0; jx < GRID_MAX_POINTS_X; jx++) {
const float rx = mesh_index_to_xpos(jx);
for (uint8_t jy = 0; jy < GRID_MAX_POINTS_Y; jy++) {
if (TEST(bitmap[jx], jy)) {
const float ry = mesh_index_to_ypos(jy),
rz = z_values[jx][jy],
w = 1.0 + weight_scaled / HYPOT((rx - px), (ry - py));
incremental_WLSF(&lsf_results, rx, ry, rz, w);
}
}
}
if (finish_incremental_LSF(&lsf_results)) {
SERIAL_ECHOLNPGM("Insufficient data");
return;
}
const float ez = -lsf_results.D - lsf_results.A * px - lsf_results.B * py;
z_values[ix][iy] = ez;
idle(); // housekeeping
}
}
}
SERIAL_ECHOLNPGM("done");
}
#endif // UBL_G29_P31
#endif // AUTO_BED_LEVELING_UBL