Commit Graph

175 Commits

Author SHA1 Message Date
Scott Lahteine
1cb810ff1c
[2.0.x] Automatically reset stepper timeout (#10179)
* Automatically reset stepper timeout in manage_inactivity

Any code that adds moves to the planner can skip resetting the stepper timeout. We can let `idle` / `manage_inactivity` reset the timer whenever it detects any moves in the planner.

* blocks_queued => has_blocks_queued
2018-03-21 19:30:06 -05:00
Scott Lahteine
bc45fb6b13 Tweak use of move_z_after_probing 2018-03-21 01:25:08 -05:00
Scott Lahteine
c352954882 Allow no raise after run_z_probe in probe_pt 2018-03-21 01:24:51 -05:00
Scott Lahteine
28f1276286
[2.0.x] Add Z_AFTER_PROBING option (#10058)
Some "fix-mounted" probes need manual stowing. And after probing some may prefer to raise or lower the nozzle. This restores an old option but tailors it to allow raise or lower as preferred.
2018-03-11 13:07:55 -05:00
Scott Lahteine
419d12ca1b Add UNKNOWN_Z_NO_RAISE option
With this option enabled, Z won't ever be raised until after `G28` has been completed, and it won't raise if Z becomes unknown. This is good for machines whose beds fall when Z is powered off.
2018-03-10 00:17:34 -06:00
Scott Lahteine
3b4c89e4b5 Move do_probe_raise closer to set_probe_deployed
…and limit the raise to Z_MAX_POS
2018-03-10 00:17:34 -06:00
Scott Lahteine
3f89bbeab5 Drop a conditional only used once 2018-02-24 16:35:31 -06:00
Scott Lahteine
b3deadd898 Don't raise FIX_MOUNTED_PROBE on stow
Reference #9336
2018-02-19 08:36:43 -06:00
Scott Lahteine
9b9350e010 Fix jerky Z motion between probes
Suggested by #9375
2018-02-02 02:32:11 -06:00
Scott Lahteine
73e32925e4 References are better for array args 2017-12-11 00:27:06 -06:00
Scott Lahteine
728acf521c Followup to #8706 2017-12-08 03:49:33 -06:00
Scott Lahteine
ae663a4198 PROBE_DOUBLE_TOUCH => MULTIPLE_PROBING 2017-12-07 16:44:13 -06:00
Scott Lahteine
a67cf78c6b Clean up whitespace, spacing 2017-11-26 20:18:52 -06:00
LVD-AC
65f365333f [2.0.x] G33 probe error handling 2017-11-25 16:19:10 -06:00
Scott Lahteine
80ada58818 One fewer function call in probe_pt 2017-11-24 17:10:38 -06:00
Scott Lahteine
c0000a0cdc Move servo code to modules/servo.* 2017-11-19 14:23:02 -06:00
Scott Lahteine
3bba7d60f3 No retroactive changes with M851 Z
If using babystep to adjust the Z probe offset, the axis will move and the mesh will be updated at the same time, causing a doubling of the Z offset over the rest of the print.

To correct for this, the current Z position would need to be modified in the opposite direction, canceling out the additional Z offset added to the mesh. This would be confusing to users, and moreover it would not be accurate without also taking the current Z fade level and current Z height into account.

It might make sense to change the mesh in the case where no babystepping is taking place, but this could be considered an undesirable side-effect of changing the `zprobe_zoffset`.

One way to remedy this would be to return to storing the mesh with `zprobe_zoffset` included, then subtracting `zprobe_zoffset` from the returned Z value. Thus, a babystep moving the Z axis up 1mm would subtract 1 from `zprobe_zoffset` while adding 1 to all mesh Z values.

Without including the `zprobe_zoffset` in the `z_values` there is no safe way to alter the mesh in conjunction with babystepping, although it's fine without it.
2017-11-18 03:36:39 -06:00
LVD-AC
e334efb2a7 PROBE_MANUALLY etc. 2017-11-10 19:27:33 -06:00
Thomas Moore
f34c3597dc Add delta_height variable in lieu of using home_offset 2017-11-08 22:10:08 -06:00
Scott Lahteine
f8393a0908 Operate in Native Machine Space 2017-11-04 00:05:38 -05:00
Scott Lahteine
3e3911fb81 Use planner.leveling_active for all leveling systems 2017-10-14 02:18:31 -05:00
Scott Lahteine
9a930ebec2 Make leveling_is_active a macro 2017-10-14 02:18:31 -05:00
Scott Lahteine
965b0ab53e Spacing adjustments 2017-10-01 21:58:50 -05:00
Thomas Moore
ddbd4b73e0 Move LPC1768 framework out of Marlin source folder 2017-09-23 16:59:31 -05:00
Scott Lahteine
551752eac7 Consolidate "bedlevel" code 2017-09-21 16:26:47 -05:00