Make Z_PROBE a Z_MIN_PROBE (PR#65)

Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.

Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX  check for the probe in update_endstops().

Using an delta related idea of @clefranc from #61,
extended to the general change for all setups.

Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc's delta.
This commit is contained in:
AnHardt
2015-08-10 10:35:39 +02:00
committed by Richard Wackerbarth
parent 8d23c4230e
commit e2d69f66b2
25 changed files with 181 additions and 191 deletions

View File

@ -4,8 +4,8 @@
#include "pins_RAMPS_13.h"
#if ENABLED(Z_PROBE_ENDSTOP)
#define Z_PROBE_PIN 19
#if ENABLED(Z_MIN_PROBE_ENDSTOP)
#define Z_MIN_PROBE_PIN 19
#endif
#undef HEATER_0_PIN