Make Z_PROBE a Z_MIN_PROBE (PR#65)
Currently we use the probe exclusively as a device to find the build platform(bed). For the currently supported setups this means, we use it as a additional min-endstop. A triggered when not deployed probe disturbs the homing process for max-endstops. Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP Adjust comments accordingly Remove Z_MAX check for the probe in update_endstops(). Using an delta related idea of @clefranc from #61, extended to the general change for all setups. Tested with Prusa i3, max-z-endstop and permanently triggered z-probe. Worked for @clefranc's delta.
This commit is contained in:
committed by
Richard Wackerbarth
parent
8d23c4230e
commit
e2d69f66b2
@@ -238,7 +238,7 @@
|
||||
#define ENDSTOPPULLUP_YMIN
|
||||
#define ENDSTOPPULLUP_ZMIN
|
||||
#endif
|
||||
#if DISABLED(DISABLE_Z_PROBE_ENDSTOP)
|
||||
#if DISABLED(DISABLE_Z_MIN_PROBE_ENDSTOP)
|
||||
#define ENDSTOPPULLUP_ZPROBE
|
||||
#endif
|
||||
#endif
|
||||
|
Reference in New Issue