G425 — Auto-calibrate Backlash and Nozzle Offsets (#13050)
This commit is contained in:
		
				
					committed by
					
						 Scott Lahteine
						Scott Lahteine
					
				
			
			
				
	
			
			
			
						parent
						
							113af46a1b
						
					
				
				
					commit
					e1604198ff
				
			| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -519,6 +519,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -524,6 +524,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -519,6 +519,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -524,6 +524,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -525,6 +525,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -533,6 +533,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,58 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -522,6 +522,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -520,6 +520,59 @@ | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Automatic backlash, position and hotend offset calibration | ||||
|  * | ||||
|  * Enable G425 to run automatic calibration using an electrically- | ||||
|  * conductive cube, bolt, or washer mounted on the bed. | ||||
|  * | ||||
|  * G425 uses the probe to touch the top and sides of the calibration object | ||||
|  * on the bed and measures and/or correct positional offsets, axis backlash | ||||
|  * and hotend offsets. | ||||
|  * | ||||
|  * Note: HOTEND_OFFSET and CALIBRATION_OBJECT_CENTER must be set to within | ||||
|  *       ±5mm of true values for G425 to succeed. | ||||
|  */ | ||||
| //#define CALIBRATION_GCODE | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
|   #define CALIBRATION_MEASUREMENT_RESOLUTION     0.01 // mm | ||||
|  | ||||
|   #define CALIBRATION_FEEDRATE_SLOW             60    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_FAST           1200    // mm/m | ||||
|   #define CALIBRATION_FEEDRATE_TRAVEL         3000    // mm/m | ||||
|  | ||||
|   // The following parameters refer to the conical section of the nozzle tip. | ||||
|   #define CALIBRATION_NOZZLE_TIP_HEIGHT          1.0  // mm | ||||
|   #define CALIBRATION_NOZZLE_OUTER_DIAMETER      2.0  // mm | ||||
|  | ||||
|   // Uncomment to enable reporting (required for "G425 V", but consumes PROGMEM). | ||||
|   //#define CALIBRATION_REPORTING | ||||
|  | ||||
|   // The true location and dimension the cube/bolt/washer on the bed. | ||||
|   #define CALIBRATION_OBJECT_CENTER     { 264.0, -22.0,  -2.0} // mm | ||||
|   #define CALIBRATION_OBJECT_DIMENSIONS {  10.0,  10.0,  10.0} // mm | ||||
|  | ||||
|   // Comment out any sides which are unreachable by the probe. For best | ||||
|   // auto-calibration results, all sides must be reachable. | ||||
|   #define CALIBRATION_MEASURE_RIGHT | ||||
|   #define CALIBRATION_MEASURE_FRONT | ||||
|   #define CALIBRATION_MEASURE_LEFT | ||||
|   #define CALIBRATION_MEASURE_BACK | ||||
|  | ||||
|   // Probing at the exact top center only works if the center is flat. If | ||||
|   // probing on a screwhead or hollow washer, probe near the edges. | ||||
|   //#define CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|  | ||||
|   // Define pin which is read during calibration | ||||
|   #ifndef CALIBRATION_PIN | ||||
|     #define CALIBRATION_PIN -1 // Override in pins.h or set to -1 to use your Z endstop | ||||
|     #define CALIBRATION_PIN_INVERTING false // set to true to invert the pin | ||||
|     //#define CALIBRATION_PIN_PULLDOWN | ||||
|     #define CALIBRATION_PIN_PULLUP | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Adaptive Step Smoothing increases the resolution of multi-axis moves, particularly at step frequencies | ||||
|  * below 1kHz (for AVR) or 10kHz (for ARM), where aliasing between axes in multi-axis moves causes audible | ||||
|   | ||||
| @@ -128,9 +128,10 @@ class restorer { | ||||
|   T  val_; | ||||
| public: | ||||
|   restorer(T& perm) : ref_(perm), val_(perm) {} | ||||
|   restorer(T& perm, T temp_val) : ref_(perm), val_(perm) { perm = temp_val; } | ||||
|   ~restorer() { restore(); } | ||||
|   inline void restore() { ref_ = val_; } | ||||
| }; | ||||
|  | ||||
| #define REMEMBER(X) restorer<typeof(X)> X##_restorer(X) | ||||
| #define RESTORE(X) X##_restorer.restore() | ||||
| #define REMEMBER(N,X, ...) restorer<typeof(X)> N##_restorer(X, ##__VA_ARGS__) | ||||
| #define RESTORE(N) N##_restorer.restore() | ||||
|   | ||||
							
								
								
									
										639
									
								
								Marlin/src/gcode/calibrate/G425.cpp
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										639
									
								
								Marlin/src/gcode/calibrate/G425.cpp
									
									
									
									
									
										Normal file
									
								
							| @@ -0,0 +1,639 @@ | ||||
| /** | ||||
|  * Marlin 3D Printer Firmware | ||||
|  * Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin] | ||||
|  * | ||||
|  * Based on Sprinter and grbl. | ||||
|  * Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm | ||||
|  * | ||||
|  * This program is free software: you can redistribute it and/or modify | ||||
|  * it under the terms of the GNU General Public License as published by | ||||
|  * the Free Software Foundation, either version 3 of the License, or | ||||
|  * (at your option) any later version. | ||||
|  * | ||||
|  * This program is distributed in the hope that it will be useful, | ||||
|  * but WITHOUT ANY WARRANTY; without even the implied warranty of | ||||
|  * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the | ||||
|  * GNU General Public License for more details. | ||||
|  * | ||||
|  * You should have received a copy of the GNU General Public License | ||||
|  * along with this program.  If not, see <http://www.gnu.org/licenses/>. | ||||
|  * | ||||
|  */ | ||||
|  | ||||
| #include "../../Marlin.h" | ||||
|  | ||||
| #if ENABLED(CALIBRATION_GCODE) | ||||
|  | ||||
| #include "../gcode.h" | ||||
| #include "../../lcd/ultralcd.h" | ||||
| #include "../../module/motion.h" | ||||
| #include "../../module/planner.h" | ||||
| #include "../../module/tool_change.h" | ||||
| #include "../../module/endstops.h" | ||||
|  | ||||
| /** | ||||
|  * G425 backs away from the calibration object by various distances | ||||
|  * depending on the confidence level: | ||||
|  * | ||||
|  *   UNKNOWN   - No real notion on where the calibration object is on the bed | ||||
|  *   UNCERTAIN - Measurement may be uncertain due to backlash | ||||
|  *   CERTAIN   - Measurement obtained with backlash compensation | ||||
|  */ | ||||
|  | ||||
| #ifndef CALIBRATION_MEASUREMENT_UNKNOWN | ||||
|   #define CALIBRATION_MEASUREMENT_UNKNOWN   5.0 // mm | ||||
| #endif | ||||
| #ifndef CALIBRATION_MEASUREMENT_UNCERTAIN | ||||
|   #define CALIBRATION_MEASUREMENT_UNCERTAIN 1.0 // mm | ||||
| #endif | ||||
| #ifndef CALIBRATION_MEASUREMENT_CERTAIN | ||||
|   #define CALIBRATION_MEASUREMENT_CERTAIN   0.5 // mm | ||||
| #endif | ||||
|  | ||||
| #define HAS_X_CENTER (ENABLED(CALIBRATION_MEASURE_LEFT)  && ENABLED(CALIBRATION_MEASURE_RIGHT)) | ||||
| #define HAS_Y_CENTER (ENABLED(CALIBRATION_MEASURE_FRONT) && ENABLED(CALIBRATION_MEASURE_BACK)) | ||||
|  | ||||
| #if ENABLED(BACKLASH_GCODE) | ||||
|   extern float backlash_distance_mm[], backlash_correction, backlash_smoothing_mm; | ||||
| #endif | ||||
|  | ||||
| enum side_t : uint8_t { TOP, RIGHT, FRONT, LEFT, BACK, NUM_SIDES }; | ||||
|  | ||||
| struct measurements_t { | ||||
|   static const float dimensions[XYZ]; | ||||
|   static const float true_center[XYZ]; // This cannot be constexpr since it is accessed by index in probe_side | ||||
|   float obj_center[XYZ] = CALIBRATION_OBJECT_CENTER; | ||||
|   float obj_side[NUM_SIDES]; | ||||
|  | ||||
|   float backlash[NUM_SIDES]; | ||||
|   float pos_error[XYZ]; | ||||
|  | ||||
|   float nozzle_outer_dimension[2] = {CALIBRATION_NOZZLE_OUTER_DIAMETER, CALIBRATION_NOZZLE_OUTER_DIAMETER}; | ||||
| }; | ||||
|  | ||||
| const float measurements_t::true_center[XYZ] = CALIBRATION_OBJECT_CENTER; | ||||
|  | ||||
| const float measurements_t::dimensions[]  = CALIBRATION_OBJECT_DIMENSIONS; | ||||
|  | ||||
| #define TEMPORARY_ENDSTOP_STATE(enable) REMEMBER(tes, soft_endstops_enabled, enable); TemporaryGlobalEndstopsState tges(enable) | ||||
|  | ||||
| #if ENABLED(BACKLASH_GCODE) | ||||
|   #define TEMPORARY_BACKLASH_STATE(enable) REMEMBER(tbst, backlash_correction, enable) | ||||
| #else | ||||
|   #define TEMPORARY_BACKLASH_STATE(enable) | ||||
| #endif | ||||
|  | ||||
| #if ENABLED(BACKLASH_GCODE) && defined(BACKLASH_SMOOTHING_MM) | ||||
|   #define TEMPORARY_BACKLASH_SMOOTHING(value) REMEMBER(tbsm, backlash_smoothing_mm, value) | ||||
| #else | ||||
|   #define TEMPORARY_BACKLASH_SMOOTHING(value) | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Move to a particular location. Up to three individual axes | ||||
|  * and their destinations can be specified, in any order. | ||||
|  */ | ||||
| inline void move_to( | ||||
|   const AxisEnum a1 = NO_AXIS, const float p1 = 0, | ||||
|   const AxisEnum a2 = NO_AXIS, const float p2 = 0, | ||||
|   const AxisEnum a3 = NO_AXIS, const float p3 = 0 | ||||
| ) { | ||||
|   set_destination_from_current(); | ||||
|  | ||||
|   // Note: The order of p1, p2, p3 may not correspond to X, Y, Z | ||||
|   if (a1 != NO_AXIS) destination[a1] = p1; | ||||
|   if (a2 != NO_AXIS) destination[a2] = p2; | ||||
|   if (a3 != NO_AXIS) destination[a3] = p3; | ||||
|  | ||||
|   // Make sure coordinates are within bounds | ||||
|   destination[X_AXIS] = MAX(MIN(destination[X_AXIS], X_MAX_POS), X_MIN_POS); | ||||
|   destination[Y_AXIS] = MAX(MIN(destination[Y_AXIS], Y_MAX_POS), Y_MIN_POS); | ||||
|   destination[Z_AXIS] = MAX(MIN(destination[Z_AXIS], Z_MAX_POS), Z_MIN_POS); | ||||
|  | ||||
|   // Move to position | ||||
|   do_blocking_move_to(destination[X_AXIS], destination[Y_AXIS], destination[Z_AXIS], MMM_TO_MMS(CALIBRATION_FEEDRATE_TRAVEL)); | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Move to the exact center above the calibration object | ||||
|  * | ||||
|  *   m                  in     - Measurement record | ||||
|  *   uncertainty        in     - How far away from the object top to park | ||||
|  */ | ||||
| inline void park_above_object(measurements_t &m, const float uncertainty) { | ||||
|   /* Move to safe distance above calibration object */ | ||||
|   move_to(Z_AXIS, m.obj_center[Z_AXIS] + m.dimensions[Z_AXIS] / 2 + uncertainty); | ||||
|  | ||||
|   /* Move to center of calibration object in XY */ | ||||
|   move_to(X_AXIS, m.obj_center[X_AXIS], Y_AXIS, m.obj_center[Y_AXIS]); | ||||
| } | ||||
|  | ||||
| #if HOTENDS > 1 | ||||
|  | ||||
|   inline void set_nozzle(measurements_t &m, const uint8_t extruder) { | ||||
|     if (extruder != active_extruder) { | ||||
|       park_above_object(m, CALIBRATION_MEASUREMENT_UNKNOWN); | ||||
|       tool_change(extruder); | ||||
|     } | ||||
|   } | ||||
|  | ||||
|   inline void reset_nozzle_offsets() { | ||||
|     constexpr float tmp[XYZ][HOTENDS] = { HOTEND_OFFSET_X, HOTEND_OFFSET_Y, HOTEND_OFFSET_Z }; | ||||
|     LOOP_XYZ(i) HOTEND_LOOP() hotend_offset[i][e] = tmp[i][e]; | ||||
|   } | ||||
|  | ||||
|   inline void normalize_hotend_offsets() { | ||||
|     for (uint8_t e = 1; e < HOTENDS; e++) { | ||||
|       hotend_offset[X_AXIS][e] -= hotend_offset[X_AXIS][0]; | ||||
|       hotend_offset[Y_AXIS][e] -= hotend_offset[Y_AXIS][0]; | ||||
|       hotend_offset[Z_AXIS][e] -= hotend_offset[Z_AXIS][0]; | ||||
|     } | ||||
|     hotend_offset[X_AXIS][0] = 0; | ||||
|     hotend_offset[Y_AXIS][0] = 0; | ||||
|     hotend_offset[Z_AXIS][0] = 0; | ||||
|   } | ||||
|  | ||||
| #endif // HOTENDS > 1 | ||||
|  | ||||
| inline bool read_calibration_pin() { | ||||
|   #if HAS_CALIBRATION_PIN | ||||
|     return (READ(CALIBRATION_PIN) != CALIBRATION_PIN_INVERTING); | ||||
|   #elif ENABLED(Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN) | ||||
|     return (READ(Z_MIN_PIN) != Z_MIN_ENDSTOP_INVERTING); | ||||
|   #else | ||||
|     return (READ(Z_MIN_PROBE_PIN) != Z_MIN_PROBE_ENDSTOP_INVERTING); | ||||
|   #endif | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Move along axis in the specified dir until the probe value becomes stop_state, | ||||
|  * then return the axis value. | ||||
|  * | ||||
|  *   axis         in - Axis along which the measurement will take place | ||||
|  *   dir          in - Direction along that axis (-1 or 1) | ||||
|  *   stop_state   in - Move until probe pin becomes this value | ||||
|  *   fast         in - Fast vs. precise measurement | ||||
|  */ | ||||
| float measuring_movement(const AxisEnum axis, const int dir, const bool stop_state, const bool fast) { | ||||
|   const float step  =            fast ? 0.25                      : CALIBRATION_MEASUREMENT_RESOLUTION; | ||||
|   const float mms   = MMM_TO_MMS(fast ? CALIBRATION_FEEDRATE_FAST : CALIBRATION_FEEDRATE_SLOW); | ||||
|   const float limit =            fast ? 50                        : 5; | ||||
|  | ||||
|   set_destination_from_current(); | ||||
|   for (float travel = 0; travel < limit; travel += step) { | ||||
|     destination[axis] += dir * step; | ||||
|     do_blocking_move_to(destination[X_AXIS], destination[Y_AXIS], destination[Z_AXIS], mms); | ||||
|     planner.synchronize(); | ||||
|     if (read_calibration_pin() == stop_state) | ||||
|       break; | ||||
|   } | ||||
|   return destination[axis]; | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Move along axis until the probe is triggered. Move toolhead to its starting | ||||
|  * point and return the measured value. | ||||
|  * | ||||
|  *   axis               in     - Axis along which the measurement will take place | ||||
|  *   dir                in     - Direction along that axis (-1 or 1) | ||||
|  *   stop_state         in     - Move until probe pin becomes this value | ||||
|  *   backlash_ptr       in/out - When not NULL, measure and record axis backlash | ||||
|  *   uncertainty        in     - If uncertainty is CALIBRATION_MEASUREMENT_UNKNOWN, do a fast probe. | ||||
|  */ | ||||
| inline float measure(const AxisEnum axis, const int dir, const bool stop_state, float * const backlash_ptr, const float uncertainty) { | ||||
|   const bool fast = uncertainty == CALIBRATION_MEASUREMENT_UNKNOWN; | ||||
|  | ||||
|   // Save position | ||||
|   set_destination_from_current(); | ||||
|   const float start_pos = destination[axis]; | ||||
|   const float measured_pos = measuring_movement(axis, dir, stop_state, fast); | ||||
|   // Measure backlash | ||||
|   if (backlash_ptr && !fast) { | ||||
|     const float release_pos = measuring_movement(axis, -dir, !stop_state, fast); | ||||
|     *backlash_ptr = ABS(release_pos - measured_pos); | ||||
|   } | ||||
|   // Return to starting position | ||||
|   destination[axis] = start_pos; | ||||
|   do_blocking_move_to(destination[X_AXIS], destination[Y_AXIS], destination[Z_AXIS], MMM_TO_MMS(CALIBRATION_FEEDRATE_TRAVEL)); | ||||
|   return measured_pos; | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Probe one side of the calibration object | ||||
|  * | ||||
|  *   m                  in/out - Measurement record, m.obj_center and m.obj_side will be updated. | ||||
|  *   uncertainty        in     - How far away from the calibration object to begin probing | ||||
|  *   side               in     - Side of probe where probe will occur | ||||
|  *   probe_top_at_edge  in     - When probing sides, probe top of calibration object nearest edge | ||||
|  *                               to find out height of edge | ||||
|  */ | ||||
| inline void probe_side(measurements_t &m, const float uncertainty, const side_t side, const bool probe_top_at_edge=false) { | ||||
|   AxisEnum axis; | ||||
|   float dir; | ||||
|  | ||||
|   park_above_object(m, uncertainty); | ||||
|  | ||||
|   switch(side) { | ||||
|     case TOP: { | ||||
|       const float measurement = measure(Z_AXIS, -1, true, &m.backlash[TOP], uncertainty); | ||||
|       m.obj_center[Z_AXIS] = measurement - m.dimensions[Z_AXIS] / 2; | ||||
|       m.obj_side[TOP] = measurement; | ||||
|       return; | ||||
|     } | ||||
|     case RIGHT: axis = X_AXIS; dir = -1; break; | ||||
|     case FRONT: axis = Y_AXIS; dir =  1; break; | ||||
|     case LEFT:  axis = X_AXIS; dir =  1; break; | ||||
|     case BACK:  axis = Y_AXIS; dir = -1; break; | ||||
|     default: | ||||
|       return; | ||||
|   } | ||||
|  | ||||
|   if (probe_top_at_edge) { | ||||
|     // Probe top nearest the side we are probing | ||||
|     move_to(axis, m.obj_center[axis] + (-dir) * (m.dimensions[axis] / 2 - m.nozzle_outer_dimension[axis])); | ||||
|     m.obj_side[TOP] = measure(Z_AXIS, -1, true, &m.backlash[TOP], uncertainty); | ||||
|     m.obj_center[Z_AXIS] = m.obj_side[TOP] - m.dimensions[Z_AXIS] / 2; | ||||
|   } | ||||
|  | ||||
|   // Move to safe distance to the side of the calibration object | ||||
|   move_to(axis, m.obj_center[axis] + (-dir) * (m.dimensions[axis] / 2 + m.nozzle_outer_dimension[axis] / 2 + uncertainty)); | ||||
|  | ||||
|   // Plunge below the side of the calibration object and measure | ||||
|   move_to(Z_AXIS, m.obj_side[TOP] - CALIBRATION_NOZZLE_TIP_HEIGHT * 0.7); | ||||
|   const float measurement = measure(axis, dir, true, &m.backlash[side], uncertainty); | ||||
|   m.obj_center[axis] = measurement + dir * (m.dimensions[axis] / 2 + m.nozzle_outer_dimension[axis] / 2); | ||||
|   m.obj_side[side] = measurement; | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Probe all sides of the calibration calibration object | ||||
|  * | ||||
|  *   m                  in/out - Measurement record: center, backlash and error values be updated. | ||||
|  *   uncertainty        in     - How far away from the calibration object to begin probing | ||||
|  */ | ||||
| inline void probe_sides(measurements_t &m, const float uncertainty) { | ||||
|   TEMPORARY_ENDSTOP_STATE(false); | ||||
|  | ||||
|   #ifdef CALIBRATION_MEASURE_AT_TOP_EDGES | ||||
|     constexpr bool probe_top_at_edge = true; | ||||
|   #else | ||||
|     /* Probing at the exact center only works if the center is flat. Probing on a washer | ||||
|      * or bolt will require probing the top near the side edges, away from the center. | ||||
|      */ | ||||
|     constexpr bool probe_top_at_edge = false; | ||||
|     probe_side(m, uncertainty, TOP); | ||||
|   #endif | ||||
|  | ||||
|   #ifdef CALIBRATION_MEASURE_RIGHT | ||||
|     probe_side(m, uncertainty, RIGHT, probe_top_at_edge); | ||||
|   #endif | ||||
|   #ifdef CALIBRATION_MEASURE_FRONT | ||||
|     probe_side(m, uncertainty, FRONT, probe_top_at_edge); | ||||
|   #endif | ||||
|   #ifdef CALIBRATION_MEASURE_LEFT | ||||
|     probe_side(m, uncertainty, LEFT,  probe_top_at_edge); | ||||
|   #endif | ||||
|   #ifdef CALIBRATION_MEASURE_BACK | ||||
|     probe_side(m, uncertainty, BACK,  probe_top_at_edge); | ||||
|   #endif | ||||
|  | ||||
|   /* Compute the measured center of the calibration object. */ | ||||
|   #if HAS_X_CENTER | ||||
|     m.obj_center[X_AXIS] = (m.obj_side[LEFT] + m.obj_side[RIGHT]) / 2; | ||||
|   #endif | ||||
|   #if HAS_Y_CENTER | ||||
|     m.obj_center[Y_AXIS] = (m.obj_side[FRONT] + m.obj_side[BACK]) / 2; | ||||
|   #endif | ||||
|  | ||||
|   /* Compute the outside diameter of the nozzle at the height | ||||
|    * at which it makes contact with the calibration object */ | ||||
|   #if HAS_X_CENTER | ||||
|     m.nozzle_outer_dimension[X_AXIS] = m.obj_side[RIGHT] - m.obj_side[LEFT] - m.dimensions[X_AXIS]; | ||||
|   #endif | ||||
|   #if HAS_Y_CENTER | ||||
|     m.nozzle_outer_dimension[Y_AXIS] = m.obj_side[BACK]  - m.obj_side[FRONT] - m.dimensions[Y_AXIS]; | ||||
|   #endif | ||||
|  | ||||
|   park_above_object(m, uncertainty); | ||||
|  | ||||
|   /* The positional error is the difference between the known calibration | ||||
|    * object location and the measured calibration object location */ | ||||
|   m.pos_error[X_AXIS] = | ||||
|   #if HAS_X_CENTER | ||||
|     m.true_center[X_AXIS] - m.obj_center[X_AXIS]; | ||||
|   #else | ||||
|     0; | ||||
|   #endif | ||||
|   m.pos_error[Y_AXIS] = | ||||
|   #if HAS_Y_CENTER | ||||
|     m.true_center[Y_AXIS] - m.obj_center[Y_AXIS]; | ||||
|   #else | ||||
|     0; | ||||
|   #endif | ||||
|   m.pos_error[Z_AXIS] = m.true_center[Z_AXIS] - m.obj_center[Z_AXIS]; | ||||
| } | ||||
|  | ||||
| #if ENABLED(CALIBRATION_REPORTING) | ||||
|   inline void report_measured_faces(const measurements_t &m) { | ||||
|     SERIAL_ECHOLNPGM("Sides:"); | ||||
|     SERIAL_ECHOLNPAIR("  Top: ", m.obj_side[TOP]); | ||||
|     #if ENABLED(CALIBRATION_MEASURE_LEFT) | ||||
|       SERIAL_ECHOLNPAIR("  Left: ", m.obj_side[LEFT]); | ||||
|     #endif | ||||
|     #if ENABLED(CALIBRATION_MEASURE_RIGHT) | ||||
|       SERIAL_ECHOLNPAIR("  Right: ", m.obj_side[RIGHT]); | ||||
|     #endif | ||||
|     #if ENABLED(CALIBRATION_MEASURE_FRONT) | ||||
|       SERIAL_ECHOLNPAIR("  Front: ", m.obj_side[FRONT]); | ||||
|     #endif | ||||
|     #if ENABLED(CALIBRATION_MEASURE_BACK) | ||||
|       SERIAL_ECHOLNPAIR("  Back: ", m.obj_side[BACK]); | ||||
|     #endif | ||||
|     SERIAL_EOL(); | ||||
|   } | ||||
|  | ||||
|   inline void report_measured_center(const measurements_t &m) { | ||||
|     SERIAL_ECHOLNPGM("Center:"); | ||||
|     #if HAS_X_CENTER | ||||
|       SERIAL_ECHOLNPAIR(" X", m.obj_center[X_AXIS]); | ||||
|     #endif | ||||
|     #if HAS_Y_CENTER | ||||
|       SERIAL_ECHOLNPAIR(" Y", m.obj_center[Y_AXIS]); | ||||
|     #endif | ||||
|     SERIAL_ECHOLNPAIR(" Z", m.obj_center[Z_AXIS]); | ||||
|     SERIAL_EOL(); | ||||
|   } | ||||
|  | ||||
|   inline void report_measured_backlash(const measurements_t &m) { | ||||
|     SERIAL_ECHOLNPGM("Backlash:"); | ||||
|     #if ENABLED(CALIBRATION_MEASURE_LEFT) | ||||
|       SERIAL_ECHOLNPAIR("  Left: ", m.backlash[LEFT]); | ||||
|     #endif | ||||
|     #if ENABLED(CALIBRATION_MEASURE_RIGHT) | ||||
|       SERIAL_ECHOLNPAIR("  Right: ", m.backlash[RIGHT]); | ||||
|     #endif | ||||
|     #if ENABLED(CALIBRATION_MEASURE_FRONT) | ||||
|       SERIAL_ECHOLNPAIR("  Front: ", m.backlash[FRONT]); | ||||
|     #endif | ||||
|     #if ENABLED(CALIBRATION_MEASURE_BACK) | ||||
|       SERIAL_ECHOLNPAIR("  Back: ", m.backlash[BACK]); | ||||
|     #endif | ||||
|     SERIAL_ECHOLNPAIR("  Top: ", m.backlash[TOP]); | ||||
|     SERIAL_EOL(); | ||||
|   } | ||||
|  | ||||
|   inline void report_measured_positional_error(const measurements_t &m) { | ||||
|     SERIAL_CHAR('T'); | ||||
|     SERIAL_ECHO(int(active_extruder)); | ||||
|     SERIAL_ECHOLNPGM(" Positional Error:"); | ||||
|     #if HAS_X_CENTER | ||||
|       SERIAL_ECHOLNPAIR(" X", m.pos_error[X_AXIS]); | ||||
|     #endif | ||||
|     #if HAS_Y_CENTER | ||||
|       SERIAL_ECHOLNPAIR(" Y", m.pos_error[Y_AXIS]); | ||||
|     #endif | ||||
|     SERIAL_ECHOLNPAIR(" Z", m.pos_error[Z_AXIS]); | ||||
|     SERIAL_EOL(); | ||||
|   } | ||||
|  | ||||
|   inline void report_measured_nozzle_dimensions(const measurements_t &m) { | ||||
|     SERIAL_ECHOLNPGM("Nozzle Tip Outer Dimensions:"); | ||||
|     #if HAS_X_CENTER | ||||
|       SERIAL_ECHOLNPAIR(" X", m.nozzle_outer_dimension[X_AXIS]); | ||||
|     #endif | ||||
|     #if HAS_Y_CENTER | ||||
|       SERIAL_ECHOLNPAIR(" Y", m.nozzle_outer_dimension[Y_AXIS]); | ||||
|     #endif | ||||
|     SERIAL_EOL(); | ||||
|   } | ||||
|  | ||||
|   #if HOTENDS > 1 | ||||
|     // | ||||
|     // This function requires normalize_hotend_offsets() to be called | ||||
|     // | ||||
|     inline void report_hotend_offsets() { | ||||
|       for (uint8_t e = 1; e < HOTENDS; e++) { | ||||
|         SERIAL_ECHOPAIR("T", int(e)); | ||||
|         SERIAL_ECHOLNPGM(" Hotend Offset:"); | ||||
|         SERIAL_ECHOLNPAIR("  X: ", hotend_offset[X_AXIS][e]); | ||||
|         SERIAL_ECHOLNPAIR("  Y: ", hotend_offset[Y_AXIS][e]); | ||||
|         SERIAL_ECHOLNPAIR("  Z: ", hotend_offset[Z_AXIS][e]); | ||||
|         SERIAL_EOL(); | ||||
|       } | ||||
|     } | ||||
|   #endif | ||||
| #endif // CALIBRATION_REPORTING | ||||
|  | ||||
| /** | ||||
|  * Probe around the calibration object to measure backlash | ||||
|  * | ||||
|  *   m              in/out - Measurement record, updated with new readings | ||||
|  *   uncertainty    in     - How far away from the object to begin probing | ||||
|  */ | ||||
| inline void calibrate_backlash(measurements_t &m, const float uncertainty) { | ||||
|   // Backlash compensation should be off while measuring backlash | ||||
|  | ||||
|   { | ||||
|     // New scope for TEMPORARY_BACKLASH_STATE | ||||
|     TEMPORARY_BACKLASH_STATE(false); | ||||
|     TEMPORARY_BACKLASH_SMOOTHING(0); | ||||
|  | ||||
|     probe_sides(m, uncertainty); | ||||
|  | ||||
|     #if ENABLED(BACKLASH_GCODE) | ||||
|       #if HAS_X_CENTER | ||||
|         backlash_distance_mm[X_AXIS] = (m.backlash[LEFT] + m.backlash[RIGHT]) / 2; | ||||
|       #elif ENABLED(CALIBRATION_MEASURE_LEFT) | ||||
|         backlash_distance_mm[X_AXIS] = m.backlash[LEFT]; | ||||
|       #elif ENABLED(CALIBRATION_MEASURE_RIGHT) | ||||
|         backlash_distance_mm[X_AXIS] = m.backlash[RIGHT]; | ||||
|       #endif | ||||
|  | ||||
|       #if HAS_Y_CENTER | ||||
|         backlash_distance_mm[Y_AXIS] = (m.backlash[FRONT] + m.backlash[BACK]) / 2; | ||||
|       #elif ENABLED(CALIBRATION_MEASURE_FRONT) | ||||
|         backlash_distance_mm[Y_AXIS] = m.backlash[FRONT]; | ||||
|       #elif ENABLED(CALIBRATION_MEASURE_BACK) | ||||
|         backlash_distance_mm[Y_AXIS] = m.backlash[BACK]; | ||||
|       #endif | ||||
|  | ||||
|       backlash_distance_mm[Z_AXIS] = m.backlash[TOP]; | ||||
|     #endif | ||||
|   } | ||||
|  | ||||
|   #if ENABLED(BACKLASH_GCODE) | ||||
|     // Turn on backlash compensation and move in all | ||||
|     // directions to take up any backlash | ||||
|  | ||||
|     { | ||||
|       // New scope for TEMPORARY_BACKLASH_STATE | ||||
|       TEMPORARY_BACKLASH_STATE(true); | ||||
|       TEMPORARY_BACKLASH_SMOOTHING(0); | ||||
|       move_to( | ||||
|         X_AXIS, current_position[X_AXIS] + 3, | ||||
|         Y_AXIS, current_position[Y_AXIS] + 3, | ||||
|         Z_AXIS, current_position[Z_AXIS] + 3 | ||||
|       ); | ||||
|       move_to( | ||||
|         X_AXIS, current_position[X_AXIS] - 3, | ||||
|         Y_AXIS, current_position[Y_AXIS] - 3, | ||||
|         Z_AXIS, current_position[Z_AXIS] - 3 | ||||
|       ); | ||||
|     } | ||||
|   #endif | ||||
| } | ||||
|  | ||||
| inline void update_measurements(measurements_t &m, const AxisEnum axis) { | ||||
|   current_position[axis] += m.pos_error[axis]; | ||||
|   m.obj_center[axis] = m.true_center[axis]; | ||||
|   m.pos_error[axis] = 0; | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Probe around the calibration object. Adjust the position and toolhead offset | ||||
|  * using the deviation from the known position of the calibration object. | ||||
|  * | ||||
|  *   m              in/out - Measurement record, updated with new readings | ||||
|  *   uncertainty    in     - How far away from the object to begin probing | ||||
|  *   extruder       in     - What extruder to probe | ||||
|  * | ||||
|  * Prerequisites: | ||||
|  *    - Call calibrate_backlash() beforehand for best accuracy | ||||
|  */ | ||||
| inline void calibrate_toolhead(measurements_t &m, const float uncertainty, const uint8_t extruder) { | ||||
|   TEMPORARY_BACKLASH_STATE(true); | ||||
|   TEMPORARY_BACKLASH_SMOOTHING(0); | ||||
|  | ||||
|   #if HOTENDS > 1 | ||||
|     set_nozzle(m, extruder); | ||||
|   #endif | ||||
|  | ||||
|   probe_sides(m, uncertainty); | ||||
|  | ||||
|   /* Adjust the hotend offset */ | ||||
|   #if HOTENDS > 1 | ||||
|     #if HAS_X_CENTER | ||||
|       hotend_offset[X_AXIS][extruder] += m.pos_error[X_AXIS]; | ||||
|     #endif | ||||
|     #if HAS_Y_CENTER | ||||
|       hotend_offset[Y_AXIS][extruder] += m.pos_error[Y_AXIS]; | ||||
|     #endif | ||||
|     hotend_offset[Z_AXIS][extruder] += m.pos_error[Z_AXIS]; | ||||
|  | ||||
|     normalize_hotend_offsets(); | ||||
|   #endif | ||||
|  | ||||
|   // Correct for positional error, so the object | ||||
|   // is at the known actual spot | ||||
|   planner.synchronize(); | ||||
|   #if HAS_X_CENTER | ||||
|     update_measurements(m, X_AXIS); | ||||
|   #endif | ||||
|   #if HAS_Y_CENTER | ||||
|     update_measurements(m, Y_AXIS); | ||||
|   #endif | ||||
|   update_measurements(m, Z_AXIS); | ||||
|  | ||||
|   sync_plan_position(); | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Probe around the calibration object for all toolheads, adjusting the coordinate | ||||
|  * system for the first nozzle and the nozzle offset for subsequent nozzles. | ||||
|  * | ||||
|  *   m              in/out - Measurement record, updated with new readings | ||||
|  *   uncertainty    in     - How far away from the object to begin probing | ||||
|  */ | ||||
| inline void calibrate_all_toolheads(measurements_t &m, const float uncertainty) { | ||||
|   TEMPORARY_BACKLASH_STATE(true); | ||||
|   TEMPORARY_BACKLASH_SMOOTHING(0); | ||||
|  | ||||
|   HOTEND_LOOP() calibrate_toolhead(m, uncertainty, e); | ||||
|  | ||||
|   #if HOTENDS > 1 | ||||
|     normalize_hotend_offsets(); | ||||
|     set_nozzle(m, 0); | ||||
|   #endif | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * Perform a full auto-calibration routine: | ||||
|  * | ||||
|  *   1) For each nozzle, touch top and sides of object to determine object position and | ||||
|  *      nozzle offsets. Do a fast but rough search over a wider area. | ||||
|  *   2) With the first nozzle, touch top and sides of object to determine backlash values | ||||
|  *      for all axis (if BACKLASH_GCODE is enabled) | ||||
|  *   3) For each nozzle, touch top and sides of object slowly to determine precise | ||||
|  *      position of object. Adjust coordinate system and nozzle offsets so probed object | ||||
|  *      location corresponds to known object location with a high degree of precision. | ||||
|  */ | ||||
| inline void calibrate_all() { | ||||
|   measurements_t m; | ||||
|  | ||||
|   #if HOTENDS > 1 | ||||
|     reset_nozzle_offsets(); | ||||
|   #endif | ||||
|  | ||||
|   TEMPORARY_BACKLASH_STATE(true); | ||||
|   TEMPORARY_BACKLASH_SMOOTHING(0); | ||||
|  | ||||
|  | ||||
|   /* Do a fast and rough calibration of the toolheads */ | ||||
|   calibrate_all_toolheads(m, CALIBRATION_MEASUREMENT_UNKNOWN); | ||||
|  | ||||
|   #if ENABLED(BACKLASH_GCODE) | ||||
|     calibrate_backlash(m, CALIBRATION_MEASUREMENT_UNCERTAIN); | ||||
|   #endif | ||||
|  | ||||
|   /* Cycle the toolheads so the servos settle into their "natural" positions */ | ||||
|   #if HOTENDS > 1 | ||||
|     HOTEND_LOOP() set_nozzle(m, e); | ||||
|   #endif | ||||
|  | ||||
|   /* Do a slow and precise calibration of the toolheads */ | ||||
|   calibrate_all_toolheads(m, CALIBRATION_MEASUREMENT_UNCERTAIN); | ||||
|  | ||||
|   move_to(X_AXIS, 150); // Park nozzle away from calibration object | ||||
| } | ||||
|  | ||||
| /** | ||||
|  * G425: Perform calibration with calibration object. | ||||
|  * | ||||
|  *   B           - Perform calibration of backlash only. | ||||
|  *   T<extruder> - Perform calibration of toolhead only. | ||||
|  *   V           - Probe object and print position, error, backlash and hotend offset. | ||||
|  *   U           - Uncertainty, how far to start probe away from the object (mm) | ||||
|  * | ||||
|  *   no args     - Perform entire calibration sequence (backlash + position on all toolheads) | ||||
|  */ | ||||
| void GcodeSuite::G425() { | ||||
|   if (axis_unhomed_error()) return; | ||||
|  | ||||
|   measurements_t m; | ||||
|  | ||||
|   float uncertainty = parser.seenval('U') ? parser.value_float() : CALIBRATION_MEASUREMENT_UNCERTAIN; | ||||
|  | ||||
|   if (parser.seen('B')) | ||||
|     calibrate_backlash(m, uncertainty); | ||||
|   else if (parser.seen('T')) | ||||
|     calibrate_toolhead(m, uncertainty, parser.has_value() ? parser.value_int() : active_extruder); | ||||
|   #if ENABLED(CALIBRATION_REPORTING) | ||||
|     else if (parser.seen('V')) { | ||||
|       probe_sides(m, uncertainty); | ||||
|       SERIAL_EOL(); | ||||
|       report_measured_faces(m); | ||||
|       report_measured_center(m); | ||||
|       report_measured_backlash(m); | ||||
|       report_measured_nozzle_dimensions(m); | ||||
|       report_measured_positional_error(m); | ||||
|       #if HOTENDS > 1 | ||||
|         normalize_hotend_offsets(); | ||||
|         report_hotend_offsets(); | ||||
|       #endif | ||||
|     } | ||||
|   #endif | ||||
|   else | ||||
|     calibrate_all(); | ||||
| } | ||||
|  | ||||
| #endif // CALIBRATION_GCODE | ||||
| @@ -270,6 +270,10 @@ void GcodeSuite::process_parsed_command( | ||||
|         case 42: G42(); break;                                    // G42: Coordinated move to a mesh point | ||||
|       #endif | ||||
|  | ||||
|       #if ENABLED(CALIBRATION_GCODE) | ||||
|         case 425: G425(); break;                                  // G425: Perform calibration with calibration cube | ||||
|       #endif | ||||
|  | ||||
|       #if ENABLED(DEBUG_GCODE_PARSER) | ||||
|         case 800: parser.debug(); break;                          // G800: GCode Parser Test for G | ||||
|       #endif | ||||
|   | ||||
| @@ -436,6 +436,10 @@ private: | ||||
|  | ||||
|   static void G92(); | ||||
|  | ||||
|   #if ENABLED(CALIBRATION_GCODE) | ||||
|     static void G425(); | ||||
|   #endif | ||||
|  | ||||
|   #if HAS_RESUME_CONTINUE | ||||
|     static void M0_M1(); | ||||
|   #endif | ||||
|   | ||||
| @@ -888,6 +888,7 @@ | ||||
| #define HAS_Z3_MIN (PIN_EXISTS(Z3_MIN)) | ||||
| #define HAS_Z3_MAX (PIN_EXISTS(Z3_MAX)) | ||||
| #define HAS_Z_MIN_PROBE_PIN (PIN_EXISTS(Z_MIN_PROBE)) | ||||
| #define HAS_CALIBRATION_PIN (PIN_EXISTS(CALIBRATION)) | ||||
|  | ||||
| // ADC Temp Sensors (Thermistor or Thermocouple with amplifier ADC interface) | ||||
| #define HAS_ADC_TEST(P) (PIN_EXISTS(TEMP_##P) && TEMP_SENSOR_##P != 0 && DISABLED(HEATER_##P##_USES_MAX6675)) | ||||
|   | ||||
| @@ -218,6 +218,16 @@ void Endstops::init() { | ||||
|     #endif | ||||
|   #endif | ||||
|  | ||||
|   #if HAS_CALIBRATION_PIN | ||||
|     #if ENABLED(CALIBRATION_PIN_PULLUP) | ||||
|       SET_INPUT_PULLUP(CALIBRATION_PIN); | ||||
|     #elif ENABLED(CALIBRATION_PIN_PULLDOWN) | ||||
|       SET_INPUT_PULLDOWN(CALIBRATION_PIN); | ||||
|     #else | ||||
|       SET_INPUT(CALIBRATION_PIN); | ||||
|     #endif | ||||
|   #endif | ||||
|  | ||||
|   #if ENABLED(Z_MIN_PROBE_ENDSTOP) | ||||
|     #if ENABLED(ENDSTOPPULLUP_ZMIN_PROBE) | ||||
|       SET_INPUT_PULLUP(Z_MIN_PROBE_PIN); | ||||
|   | ||||
| @@ -97,6 +97,8 @@ class Endstops { | ||||
|       ); | ||||
|     } | ||||
|  | ||||
|     static inline bool global_enabled() { return enabled_globally; } | ||||
|  | ||||
|     /** | ||||
|      * Periodic call to poll endstops if required. Called from temperature ISR | ||||
|      */ | ||||
| @@ -173,3 +175,17 @@ class Endstops { | ||||
| }; | ||||
|  | ||||
| extern Endstops endstops; | ||||
|  | ||||
| /** | ||||
|  * A class to save and change the endstop state, | ||||
|  * then restore it when it goes out of scope. | ||||
|  */ | ||||
| class TemporaryGlobalEndstopsState { | ||||
|   bool saved; | ||||
|  | ||||
|   public: | ||||
|     TemporaryGlobalEndstopsState(const bool enable) : saved(endstops.global_enabled()) { | ||||
|       endstops.enable_globally(enable); | ||||
|     } | ||||
|     ~TemporaryGlobalEndstopsState() { endstops.enable_globally(saved); } | ||||
| }; | ||||
|   | ||||
| @@ -20,7 +20,7 @@ opt_set TEMP_SENSOR_0 1 | ||||
| opt_set TEMP_SENSOR_1 5 | ||||
| opt_set TEMP_SENSOR_BED 1 | ||||
| opt_enable REPRAP_DISCOUNT_FULL_GRAPHIC_SMART_CONTROLLER SDSUPPORT \ | ||||
|            FILAMENT_WIDTH_SENSOR FILAMENT_LCD_DISPLAY \ | ||||
|            FILAMENT_WIDTH_SENSOR FILAMENT_LCD_DISPLAY CALIBRATION_GCODE \ | ||||
|            FIX_MOUNTED_PROBE Z_SAFE_HOMING AUTO_BED_LEVELING_BILINEAR Z_MIN_PROBE_REPEATABILITY_TEST DEBUG_LEVELING_FEATURE \ | ||||
|            BABYSTEPPING BABYSTEP_XY BABYSTEP_ZPROBE_OFFSET BABYSTEP_ZPROBE_GFX_OVERLAY \ | ||||
|            PRINTCOUNTER NOZZLE_PARK_FEATURE NOZZLE_CLEAN_FEATURE SLOW_PWM_HEATERS PIDTEMPBED EEPROM_SETTINGS INCH_MODE_SUPPORT TEMPERATURE_UNITS_SUPPORT M100_FREE_MEMORY_WATCHER \ | ||||
|   | ||||
		Reference in New Issue
	