Remove PID examples from preconfigured configs
This commit is contained in:
committed by
Richard Wackerbarth
parent
7456710a1f
commit
de25a48dec
@ -209,27 +209,11 @@ Here are some standard links for getting your machine calibrated:
|
||||
#define PID_INTEGRAL_DRIVE_MAX PID_MAX //limit for the integral term
|
||||
#define K1 0.95 //smoothing factor within the PID
|
||||
|
||||
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
|
||||
// Ultimaker
|
||||
//#define DEFAULT_Kp 22.2
|
||||
//#define DEFAULT_Ki 1.08
|
||||
//#define DEFAULT_Kd 114
|
||||
|
||||
// Kossel Pro
|
||||
#define DEFAULT_Kp 19.30
|
||||
#define DEFAULT_Ki 3.51
|
||||
#define DEFAULT_Kd 26.56
|
||||
|
||||
// MakerGear
|
||||
//#define DEFAULT_Kp 7.0
|
||||
//#define DEFAULT_Ki 0.1
|
||||
//#define DEFAULT_Kd 12
|
||||
|
||||
// Mendel Parts V9 on 12V
|
||||
//#define DEFAULT_Kp 63.0
|
||||
//#define DEFAULT_Ki 2.25
|
||||
//#define DEFAULT_Kd 440
|
||||
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
@ -266,18 +250,6 @@ Here are some standard links for getting your machine calibrated:
|
||||
#define DEFAULT_bedKi 62.77
|
||||
#define DEFAULT_bedKd 545.98
|
||||
|
||||
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
||||
//from FOPDT model - kp=.39 Tp=405 Tdead=66, Tc set to 79.2, aggressive factor of .15 (vs .1, 1, 10)
|
||||
//#define DEFAULT_bedKp 10.00
|
||||
//#define DEFAULT_bedKi .023
|
||||
//#define DEFAULT_bedKd 305.4
|
||||
|
||||
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
||||
//from pidautotune
|
||||
//#define DEFAULT_bedKp 97.1
|
||||
//#define DEFAULT_bedKi 1.41
|
||||
//#define DEFAULT_bedKd 1675.16
|
||||
|
||||
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
|
||||
#endif // PIDTEMPBED
|
||||
|
||||
|
Reference in New Issue
Block a user