Make Z Probe options independent of ABL

This commit is contained in:
Scott Lahteine
2016-06-14 18:03:17 -07:00
parent 43ec24158e
commit de12228758
23 changed files with 1459 additions and 1238 deletions

View File

@ -495,12 +495,102 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
//
// Probe Type
// Probes are sensors/switches that are activated / deactivated before/after use.
//
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, etc.
// You must activate one of these to use AUTO_BED_LEVELING_FEATURE below.
//
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
//
// A fix mounted probe, like the normal inductive probe, must be deactivated to go
// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// Z Servo Probe, such as an endstop switch on a rotating arm.
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Deploy and Stow angles
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (XY_TRAVEL_SPEED)/10
#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0 // Move the probe into position
#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE XY_TRAVEL_SPEED
#define Z_PROBE_ALLEN_KEY_STOW_2_X -64.0 // Push it down
#define Z_PROBE_ALLEN_KEY_STOW_2_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 3.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (XY_TRAVEL_SPEED)/10
#define Z_PROBE_ALLEN_KEY_STOW_3_X -64.0 // Move it up to clear
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 50.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE XY_TRAVEL_SPEED
#endif // Z_PROBE_ALLEN_KEY
//
// Probe Raise options provide clearance for the probe to deploy and stow.
//
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 50 // Raise before probe stow (e.g., the last probe).
//
// For M851 give a range for adjusting the Z probe offset
//
#define Z_PROBE_OFFSET_RANGE_MIN -20
#define Z_PROBE_OFFSET_RANGE_MAX 20
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -652,27 +742,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#endif // !AUTO_BED_LEVELING_GRID
// Z Probe to nozzle (X,Y) offset, relative to (0, 0).
// X and Y offsets must be integers.
//
// In the following example the X and Y offsets are both positive:
// #define X_PROBE_OFFSET_FROM_EXTRUDER 10
// #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
//
// +-- BACK ---+
// | |
// L | (+) P | R <-- probe (20,20)
// E | | I
// F | (-) N (+) | G <-- nozzle (10,10)
// T | | H
// | (-) | T
// | |
// O-- FRONT --+
// (0,0)
#define X_PROBE_OFFSET_FROM_EXTRUDER 0 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER -10 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -3.5 // Z offset: -below +above [the nozzle]
#define XY_TRAVEL_SPEED 4000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points
@ -680,61 +749,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.
// Useful to retract a deployable Z probe.
// Probes are sensors/switches that need to be activated before they can be used
// and deactivated after their use.
// Allen Key Probes, Servo Probes, Z-Sled Probes, FIX_MOUNTED_PROBE, ... . You have to activate one of these for the AUTO_BED_LEVELING_FEATURE
// A fix mounted probe, like the normal inductive probe, must be deactivated to go below Z_PROBE_OFFSET_FROM_EXTRUDER
// when the hardware endstops are active.
//#define FIX_MOUNTED_PROBE
// A Servo Probe can be defined in the servo section below.
// An Allen Key Probe is currently predefined only in the delta example configurations.
// Enable if you have a Z probe mounted on a sled like those designed by Charles Bell.
//#define Z_PROBE_SLED
//#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
// For example any setup that uses the nozzle itself as a probe.
//#define MECHANICAL_PROBE
// Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe
// Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN.
//#define Z_PROBE_ALLEN_KEY
#if ENABLED(Z_PROBE_ALLEN_KEY)
// 2 or 3 sets of coordinates for deploying and retracting the spring loaded touch probe on G29,
// if servo actuated touch probe is not defined. Uncomment as appropriate for your printer/probe.
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_X 30.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_X 0.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Y DELTA_PRINTABLE_RADIUS
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_Z 100.0
#define Z_PROBE_ALLEN_KEY_DEPLOY_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/10
#define Z_PROBE_ALLEN_KEY_STOW_1_X -64.0 // Move the probe into position
#define Z_PROBE_ALLEN_KEY_STOW_1_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_1_Z 23.0
#define Z_PROBE_ALLEN_KEY_STOW_1_FEEDRATE HOMING_FEEDRATE_XYZ
#define Z_PROBE_ALLEN_KEY_STOW_2_X -64.0 // Push it down
#define Z_PROBE_ALLEN_KEY_STOW_2_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_2_Z 3.0
#define Z_PROBE_ALLEN_KEY_STOW_2_FEEDRATE (HOMING_FEEDRATE_XYZ)/10
#define Z_PROBE_ALLEN_KEY_STOW_3_X -64.0 // Move it up to clear
#define Z_PROBE_ALLEN_KEY_STOW_3_Y 56.0
#define Z_PROBE_ALLEN_KEY_STOW_3_Z 50.0
#define Z_PROBE_ALLEN_KEY_STOW_3_FEEDRATE HOMING_FEEDRATE_XYZ
#endif // Z_PROBE_ALLEN_KEY
// If you've enabled AUTO_BED_LEVELING_FEATURE and are using the Z Probe for Z Homing,
// it is highly recommended you also enable Z_SAFE_HOMING below!
@ -1230,14 +1244,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
//
//#define NUM_SERVOS 3 // Servo index starts with 0 for M280 command
// Servo Endstops
//
// This allows for servo actuated endstops, primary usage is for the Z Axis to eliminate calibration or bed height changes.
// Use M851 to set the Z probe vertical offset from the nozzle. Store that setting with M500.
//
//#define Z_ENDSTOP_SERVO_NR 0
//#define Z_SERVO_ANGLES {70,0} // Z Servo Extend and Retract angles
// Servo deactivation
//
// With this option servos are powered only during movement, then turned off to prevent jitter.