Show Temperature ADC values

If "SHOW_TEMP_ADC_VALUES" is defined in Configuration_adv.h, the M105
command will present, after tradicional temperatures, the ADC value read
from temp sensors. This is great for adjusting thermistor tables with
thermocouple.

From Pronterface you can see the ADC value and compare with a
thermocouple reading.. then you just need to create your own thermistor
table.

Since this merge doesnt change the original information, it doesnt mess
with PC software parsing (tested under Pronterface and Repetier-Host).
This commit is contained in:
Alex Borro
2013-10-12 10:41:23 -03:00
parent 7fad13a1e2
commit dd3086d3f2
3 changed files with 35 additions and 0 deletions

View File

@@ -40,6 +40,10 @@
#define AUTOTEMP_OLDWEIGHT 0.98
#endif
//Show Temperature ADC value
//The M105 command return, besides traditional information, the ADC value read from temperature sensors.
//#define SHOW_TEMP_ADC_VALUES
// extruder run-out prevention.
//if the machine is idle, and the temperature over MINTEMP, every couple of SECONDS some filament is extruded
//#define EXTRUDER_RUNOUT_PREVENT