Consolidate 3-point leveling point options
This commit is contained in:
@@ -365,7 +365,7 @@
|
||||
#define PIDTEMP
|
||||
#define BANG_MAX 255 // Limits current to nozzle while in bang-bang mode; 255=full current
|
||||
#define PID_MAX BANG_MAX // Limits current to nozzle while PID is active (see PID_FUNCTIONAL_RANGE below); 255=full current
|
||||
#define PID_K1 0.95 // Smoothing factor within any PID loop
|
||||
#define PID_K1 0.95 // Smoothing factor within the PID
|
||||
#if ENABLED(PIDTEMP)
|
||||
//#define PID_AUTOTUNE_MENU // Add PID Autotune to the LCD "Temperature" menu to run M303 and apply the result.
|
||||
//#define PID_DEBUG // Sends debug data to the serial port.
|
||||
@@ -947,7 +947,7 @@
|
||||
/**
|
||||
* Enable the G26 Mesh Validation Pattern tool.
|
||||
*/
|
||||
#define G26_MESH_VALIDATION
|
||||
#define G26_MESH_VALIDATION // Enable G26 mesh validation
|
||||
#if ENABLED(G26_MESH_VALIDATION)
|
||||
#define MESH_TEST_NOZZLE_SIZE 0.4 // (mm) Diameter of primary nozzle.
|
||||
#define MESH_TEST_LAYER_HEIGHT 0.2 // (mm) Default layer height for the G26 Mesh Validation Tool.
|
||||
@@ -963,12 +963,11 @@
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
|
||||
#define FRONT_PROBE_BED_POSITION 15
|
||||
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
|
||||
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
|
||||
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -991,17 +990,6 @@
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@@ -1014,13 +1002,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1041,6 +1022,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
@@ -1577,7 +1571,7 @@
|
||||
//
|
||||
// ANET and Tronxy Controller supported displays.
|
||||
//
|
||||
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
|
||||
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
|
||||
// This LCD is known to be susceptible to electrical interference
|
||||
// which scrambles the display. Pressing any button clears it up.
|
||||
// This is a LCD2004 display with 5 analog buttons.
|
||||
|
@@ -963,12 +963,11 @@
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION 270
|
||||
#define FRONT_PROBE_BED_POSITION 20
|
||||
#define BACK_PROBE_BED_POSITION 260
|
||||
//#define LEFT_PROBE_BED_POSITION 15
|
||||
//#define RIGHT_PROBE_BED_POSITION 270
|
||||
//#define FRONT_PROBE_BED_POSITION 20
|
||||
//#define BACK_PROBE_BED_POSITION 260
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -991,17 +990,6 @@
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@@ -1014,13 +1002,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1041,6 +1022,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
@@ -974,12 +974,11 @@
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
|
||||
#define FRONT_PROBE_BED_POSITION 15
|
||||
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
|
||||
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
|
||||
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -1002,17 +1001,6 @@
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@@ -1025,13 +1013,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1052,6 +1033,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
@@ -1588,10 +1582,10 @@
|
||||
//
|
||||
// ANET and Tronxy Controller supported displays.
|
||||
//
|
||||
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
|
||||
// This LCD is known to be susceptible to electrical interference
|
||||
// which scrambles the display. Pressing any button clears it up.
|
||||
// This is a LCD2004 display with 5 analog buttons.
|
||||
#define ZONESTAR_LCD // Requires ADC_KEYPAD_PIN to be assigned to an analog pin.
|
||||
// This LCD is known to be susceptible to electrical interference
|
||||
// which scrambles the display. Pressing any button clears it up.
|
||||
// This is a LCD2004 display with 5 analog buttons.
|
||||
|
||||
//#define ANET_FULL_GRAPHICS_LCD // Anet 128x64 full graphics lcd with rotary encoder as used on Anet A6
|
||||
// A clone of the RepRapDiscount full graphics display but with
|
||||
|
Reference in New Issue