Consolidate 3-point leveling point options
This commit is contained in:
@@ -21,7 +21,7 @@
|
||||
*/
|
||||
|
||||
/**
|
||||
* Malyan M150 Configuration
|
||||
* Maylan M150 Configuration
|
||||
* Non-Automatic Bed Level config by default
|
||||
*/
|
||||
|
||||
@@ -778,8 +778,8 @@
|
||||
* Example: `M851 Z-5` with a CLEARANCE of 4 => 9mm from bed to nozzle.
|
||||
* But: `M851 Z+1` with a CLEARANCE of 2 => 2mm from bed to nozzle.
|
||||
*/
|
||||
#define Z_CLEARANCE_DEPLOY_PROBE 10 // Z Clearance for Deploy/Stow
|
||||
#define Z_CLEARANCE_BETWEEN_PROBES 5 // Z Clearance between probe points
|
||||
//#define Z_CLEARANCE_DEPLOY_PROBE 10 // Z Clearance for Deploy/Stow
|
||||
//#define Z_CLEARANCE_BETWEEN_PROBES 5 // Z Clearance between probe points
|
||||
//#define Z_AFTER_PROBING 5 // Z position after probing is done
|
||||
|
||||
// For M851 give a range for adjusting the Z probe offset
|
||||
@@ -992,11 +992,10 @@
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 50
|
||||
#define RIGHT_PROBE_BED_POSITION 150
|
||||
#define FRONT_PROBE_BED_POSITION 50
|
||||
#define BACK_PROBE_BED_POSITION 150
|
||||
|
||||
//#define LEFT_PROBE_BED_POSITION 50
|
||||
//#define RIGHT_PROBE_BED_POSITION 150
|
||||
//#define FRONT_PROBE_BED_POSITION 50
|
||||
//#define BACK_PROBE_BED_POSITION 150
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -1023,12 +1022,12 @@
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 50
|
||||
#define ABL_PROBE_PT_1_Y 150
|
||||
#define ABL_PROBE_PT_2_X 50
|
||||
#define ABL_PROBE_PT_2_Y 50
|
||||
#define ABL_PROBE_PT_3_X 150
|
||||
#define ABL_PROBE_PT_3_Y 50
|
||||
#define PROBE_PT_1_X 50
|
||||
#define PROBE_PT_1_Y 150
|
||||
#define PROBE_PT_2_X 50
|
||||
#define PROBE_PT_2_Y 50
|
||||
#define PROBE_PT_3_X 150
|
||||
#define PROBE_PT_3_Y 50
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
@@ -1042,13 +1041,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1069,6 +1061,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
@@ -962,12 +962,11 @@
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
|
||||
#define FRONT_PROBE_BED_POSITION 15
|
||||
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
|
||||
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
|
||||
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -990,17 +989,6 @@
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@@ -1013,13 +1001,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1040,6 +1021,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
Reference in New Issue