Consolidate 3-point leveling point options
This commit is contained in:
@@ -951,12 +951,11 @@
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
|
||||
#define FRONT_PROBE_BED_POSITION 15
|
||||
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
|
||||
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
|
||||
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -979,17 +978,6 @@
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@@ -1002,13 +990,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1029,6 +1010,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
@@ -159,7 +159,7 @@
|
||||
#define EXTRUDERS 1
|
||||
|
||||
// Generally expected filament diameter (1.75, 2.85, 3.0, ...). Used for Volumetric, Filament Width Sensor, etc.
|
||||
#define DEFAULT_NOMINAL_FILAMENT_DIA 3.0
|
||||
#define DEFAULT_NOMINAL_FILAMENT_DIA 1.75
|
||||
|
||||
// For Cyclops or any "multi-extruder" that shares a single nozzle.
|
||||
//#define SINGLENOZZLE
|
||||
@@ -965,11 +965,10 @@
|
||||
#define GRID_MAX_POINTS_Y 4
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION X_MIN_POS + (X_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
#define RIGHT_PROBE_BED_POSITION X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
#define FRONT_PROBE_BED_POSITION Y_MIN_POS + (Y_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
#define BACK_PROBE_BED_POSITION Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
|
||||
//#define LEFT_PROBE_BED_POSITION X_MIN_POS + (X_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
//#define RIGHT_PROBE_BED_POSITION X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
//#define FRONT_PROBE_BED_POSITION Y_MIN_POS + (Y_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
//#define BACK_PROBE_BED_POSITION Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -996,12 +995,12 @@
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X X_MIN_POS + X_PROBE_OFFSET_FROM_EXTRUDER
|
||||
#define ABL_PROBE_PT_1_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
|
||||
#define ABL_PROBE_PT_2_X X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
#define ABL_PROBE_PT_2_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
|
||||
#define ABL_PROBE_PT_3_X ((X_MIN_POS + X_MAX_POS) / 2)
|
||||
#define ABL_PROBE_PT_3_Y Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
#define PROBE_PT_1_X X_MIN_POS + X_PROBE_OFFSET_FROM_EXTRUDER
|
||||
#define PROBE_PT_1_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
|
||||
#define PROBE_PT_2_X X_MAX_POS - (X_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
#define PROBE_PT_2_Y Y_MIN_POS + Y_PROBE_OFFSET_FROM_EXTRUDER
|
||||
#define PROBE_PT_3_X ((X_MIN_POS + X_MAX_POS) / 2)
|
||||
#define PROBE_PT_3_Y Y_MAX_POS - (Y_PROBE_OFFSET_FROM_EXTRUDER)
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
@@ -1015,13 +1014,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1042,6 +1034,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
@@ -951,12 +951,11 @@
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - 15)
|
||||
#define FRONT_PROBE_BED_POSITION 15
|
||||
#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - 15)
|
||||
//#define LEFT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define RIGHT_PROBE_BED_POSITION (X_BED_SIZE - MIN_PROBE_EDGE)
|
||||
//#define FRONT_PROBE_BED_POSITION MIN_PROBE_EDGE
|
||||
//#define BACK_PROBE_BED_POSITION (Y_BED_SIZE - MIN_PROBE_EDGE)
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@@ -979,17 +978,6 @@
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@@ -1002,13 +990,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@@ -1029,6 +1010,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
Reference in New Issue