Consolidate 3-point leveling point options
This commit is contained in:
@ -810,8 +810,8 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
||||
|
||||
//#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off.
|
||||
|
||||
#define Z_HOMING_HEIGHT 10 // (in mm) Minimal z height before homing (G28) for Z clearance above the bed, clamps, ...
|
||||
// Be sure you have this distance over your Z_MAX_POS in case.
|
||||
#define Z_HOMING_HEIGHT 8 // (in mm) Minimal z height before homing (G28) for Z clearance above the bed, clamps, ...
|
||||
// Be sure you have this distance over your Z_MAX_POS in case.
|
||||
|
||||
// Direction of endstops when homing; 1=MAX, -1=MIN
|
||||
// :[-1,1]
|
||||
@ -963,12 +963,11 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION 170
|
||||
#define FRONT_PROBE_BED_POSITION 20
|
||||
#define BACK_PROBE_BED_POSITION 170
|
||||
//#define LEFT_PROBE_BED_POSITION 15
|
||||
//#define RIGHT_PROBE_BED_POSITION 170
|
||||
//#define FRONT_PROBE_BED_POSITION 20
|
||||
//#define BACK_PROBE_BED_POSITION 170
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@ -991,17 +990,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@ -1014,13 +1002,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@ -1041,6 +1022,19 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
@ -528,13 +528,13 @@
|
||||
#endif
|
||||
|
||||
// Mechanical endstop with COM to ground and NC to Signal uses "false" here (most common setup).
|
||||
#define X_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Y_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Z_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define X_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Y_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the probe.
|
||||
const bool X_MIN_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
|
||||
const bool Y_MIN_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
|
||||
const bool Z_MIN_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
|
||||
const bool X_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
|
||||
const bool Y_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
|
||||
const bool Z_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
|
||||
const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the logic of the endstop.
|
||||
|
||||
// Enable this feature if all enabled endstop pins are interrupt-capable.
|
||||
// This will remove the need to poll the interrupt pins, saving many CPU cycles.
|
||||
@ -963,12 +963,11 @@
|
||||
#define GRID_MAX_POINTS_X 3
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
|
||||
// Set the boundaries for probing (where the probe can reach).
|
||||
#define LEFT_PROBE_BED_POSITION 15
|
||||
#define RIGHT_PROBE_BED_POSITION 170
|
||||
#define FRONT_PROBE_BED_POSITION 20
|
||||
#define BACK_PROBE_BED_POSITION 170
|
||||
//#define LEFT_PROBE_BED_POSITION 15
|
||||
//#define RIGHT_PROBE_BED_POSITION 170
|
||||
//#define FRONT_PROBE_BED_POSITION 20
|
||||
//#define BACK_PROBE_BED_POSITION 170
|
||||
|
||||
// Probe along the Y axis, advancing X after each column
|
||||
//#define PROBE_Y_FIRST
|
||||
@ -991,17 +990,6 @@
|
||||
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// 3 arbitrary points to probe.
|
||||
// A simple cross-product is used to estimate the plane of the bed.
|
||||
#define ABL_PROBE_PT_1_X 15
|
||||
#define ABL_PROBE_PT_1_Y 180
|
||||
#define ABL_PROBE_PT_2_X 15
|
||||
#define ABL_PROBE_PT_2_Y 20
|
||||
#define ABL_PROBE_PT_3_X 170
|
||||
#define ABL_PROBE_PT_3_Y 20
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
//===========================================================================
|
||||
@ -1014,13 +1002,6 @@
|
||||
#define GRID_MAX_POINTS_X 10 // Don't use more than 15 points per axis, implementation limited.
|
||||
#define GRID_MAX_POINTS_Y GRID_MAX_POINTS_X
|
||||
|
||||
#define UBL_PROBE_PT_1_X 39 // Probing points for 3-Point leveling of the mesh
|
||||
#define UBL_PROBE_PT_1_Y 180
|
||||
#define UBL_PROBE_PT_2_X 39
|
||||
#define UBL_PROBE_PT_2_Y 20
|
||||
#define UBL_PROBE_PT_3_X 180
|
||||
#define UBL_PROBE_PT_3_Y 20
|
||||
|
||||
#define UBL_MESH_EDIT_MOVES_Z // Sophisticated users prefer no movement of nozzle
|
||||
#define UBL_SAVE_ACTIVE_ON_M500 // Save the currently active mesh in the current slot on M500
|
||||
|
||||
@ -1041,6 +1022,19 @@
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Points to probe for all 3-point Leveling procedures.
|
||||
* Override if the automatically selected points are inadequate.
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT) || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
//#define PROBE_PT_1_X 15
|
||||
//#define PROBE_PT_1_Y 180
|
||||
//#define PROBE_PT_2_X 15
|
||||
//#define PROBE_PT_2_Y 20
|
||||
//#define PROBE_PT_3_X 170
|
||||
//#define PROBE_PT_3_Y 20
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
|
Reference in New Issue