@ -482,6 +482,12 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
// If you're using the Z MIN endstop connector for your Z probe, this has no effect.
//#define DISABLE_Z_MIN_PROBE_ENDSTOP
// Probe Raise options provide clearance for the probe to deploy and stow.
// For G28 these apply when the probe deploys and stows.
// For G29 these apply before and after the full procedure.
#define Z_RAISE_BEFORE_PROBING 15 // Raise before probe deploy (e.g., the first probe).
#define Z_RAISE_AFTER_PROBING 50 // Raise before probe stow (e.g., the last probe).
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
// :{0:'Low',1:'High'}
#define X_ENABLE_ON 0
@ -656,9 +662,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
#define XY_TRAVEL_SPEED 4000 // X and Y axis travel speed between probes, in mm/min.
#define Z_RAISE_BEFORE_PROBING 15 // How much the Z axis will be raised before traveling to the first probing point.
#define Z_RAISE_BETWEEN_PROBINGS 5 // How much the Z axis will be raised when traveling from between next probing points
#define Z_RAISE_AFTER_PROBING 50 // How much the Z axis will be raised after the last probing point.
//#define Z_PROBE_END_SCRIPT "G1 Z10 F12000\nG1 X15 Y330\nG1 Z0.5\nG1 Z10" // These commands will be executed in the end of G29 routine.