Merge pull request #3206 from esenapaj/patch-5

Follow-up the PR #3082, etc
This commit is contained in:
Scott Lahteine
2016-03-24 00:20:25 -07:00
19 changed files with 271 additions and 321 deletions

View File

@ -335,8 +335,8 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//============================= Z Probe Options =============================
//===========================================================================
// Enable Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to use the Z_MIN_PIN for your Z_MIN_PROBE.
// The Z_MIN_PIN will then be used for both Z-homing and probing.
// Enable Z_MIN_PROBE_ENDSTOP to use _both_ a Z Probe and a Z-min-endstop on the same machine.
// With this option the Z_MIN_PROBE_PIN will only be used for probing, never for homing.
//
// *** PLEASE READ ALL INSTRUCTIONS BELOW FOR SAFETY! ***
//
@ -367,13 +367,12 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
//
//#define Z_MIN_PROBE_ENDSTOP
// If you want to use the Z_MIN_PIN to connect your Z_MIN_PROBE comment out the next define.
// In other words. The z-min-probe is connected to the Z_MIN_PIN and is used for homing and for probing.
// Enable Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to use the Z_MIN_PIN for your Z_MIN_PROBE.
// The Z_MIN_PIN will then be used for both Z-homing and probing.
#define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN
// If you want to use a probe you do have to define one of the two defines above!
// To use a probe you must enable one of the two options above!
//
// This option disables the use of the Z_MIN_PROBE_PIN
// To enable the Z probe pin but disable its use, uncomment the line below. This only affects a
// Z probe switch if you have a separate Z min endstop also and have activated Z_MIN_PROBE_ENDSTOP above.
@ -483,7 +482,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#define AUTO_BED_LEVELING_FEATURE // Delete the comment to enable (remove // at the start of the line)
//#define DEBUG_LEVELING_FEATURE
#define Z_MIN_PROBE_REPEATABILITY_TEST // If not commented out, Z-Probe Repeatability test will be included if Auto Bed Leveling is Enabled.
#define Z_MIN_PROBE_REPEATABILITY_TEST // If not commented out, Z Probe Repeatability test will be included if Auto Bed Leveling is Enabled.
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
@ -584,7 +583,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// - Position the Z probe in a defined XY point before Z Homing when homing all axis (G28).
// - Block Z homing only when the Z probe is outside bed area.
#if ENABLED(Z_SAFE_HOMING)
#define Z_SAFE_HOMING_X_POINT ((X_MIN_POS + X_MAX_POS) / 2) // X point for Z homing when homing all axis (G28).