Added new menu items under the prepare submenu.

Instead of a single pre-heat, now there is pre-heat ABS and PLA options
Added defines to the configuration file to adjust preheat temperatures for both
This commit is contained in:
Blair Thompson
2012-02-22 22:51:04 +00:00
parent ae3e7586c6
commit d9f2f509d5
5 changed files with 17 additions and 9 deletions

View File

@ -26,7 +26,7 @@
// Gen7 v1.3 = 79
// Teensylu = 8,
// Gen3+ =9
#define MOTHERBOARD 7
#define MOTHERBOARD 33
//===========================================================================
//=============================Thermal Settings ============================
@ -44,7 +44,7 @@
// 6 is EPCOS 100k
// 7 is 100k Honeywell thermistor 135-104LAG-J01
#define TEMP_SENSOR_0 -1
#define TEMP_SENSOR_0 1
#define TEMP_SENSOR_1 0
#define TEMP_SENSOR_2 0
#define TEMP_SENSOR_BED 1
@ -129,7 +129,7 @@ const bool Z_ENDSTOPS_INVERTING = false; // set to true to invert the logic of t
#define INVERT_X_DIR false // for Mendel set to false, for Orca set to true
#define INVERT_Y_DIR true // for Mendel set to true, for Orca set to false
#define INVERT_Z_DIR false // for Mendel set to false, for Orca set to true
#define INVERT_Z_DIR true // for Mendel set to false, for Orca set to true
#define INVERT_E0_DIR false // for direct drive extruder v9 set to true, for geared extruder set to false
#define INVERT_E1_DIR false // for direct drive extruder v9 set to true, for geared extruder set to false
#define INVERT_E2_DIR false // for direct drive extruder v9 set to true, for geared extruder set to false
@ -194,6 +194,10 @@ const bool Z_ENDSTOPS_INVERTING = false; // set to true to invert the logic of t
#define ULTRA_LCD
#define LCD_WIDTH 20
#define LCD_HEIGHT 4
#define PLA_PREHEAT_HOTEND_TEMP 180
#define PLA_PREHEAT_HPB_TEMP 70
#define ABS_PREHEAT_HOTEND_TEMP 240
#define ABS_PREHEAT_HPB_TEMP 100
#else //no panel but just lcd
#ifdef ULTRA_LCD
#define LCD_WIDTH 16