Use WATCH_TEMP_INCREASE + TEMP_HYSTERESIS + 1 as difference limit
This commit is contained in:
		| @@ -25,7 +25,7 @@ | ||||
|    * Whenever an M104 or M109 increases the target temperature the firmware will wait for the | ||||
|    * WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE | ||||
|    * degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109, | ||||
|    * but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees. | ||||
|    * but only if the current temperature is far enough below the target for a reliable test. | ||||
|    */ | ||||
|   #define WATCH_TEMP_PERIOD 16                // Seconds | ||||
|   #define WATCH_TEMP_INCREASE 4               // Degrees Celsius | ||||
|   | ||||