Univeral Bed Leveling - configuration
This commit is contained in:
@ -388,10 +388,13 @@ static_assert(1 >= 0
|
||||
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
+ 1
|
||||
#endif
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
+ 1
|
||||
#endif
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
+ 1
|
||||
#endif
|
||||
, "Select only one of: MESH_BED_LEVELING, AUTO_BED_LEVELING_LINEAR, AUTO_BED_LEVELING_3POINT, or AUTO_BED_LEVELING_BILINEAR."
|
||||
, "Select only one of: MESH_BED_LEVELING, AUTO_BED_LEVELING_LINEAR, AUTO_BED_LEVELING_3POINT, AUTO_BED_LEVELING_BILINEAR or AUTO_BED_LEVELING_UBL."
|
||||
);
|
||||
|
||||
/**
|
||||
@ -403,6 +406,21 @@ static_assert(1 >= 0
|
||||
#elif MESH_NUM_X_POINTS > 9 || MESH_NUM_Y_POINTS > 9
|
||||
#error "MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS must be less than 10."
|
||||
#endif
|
||||
#elif ENABLED(MANUAL_BED_LEVELING)
|
||||
#error "MANUAL_BED_LEVELING only applies to MESH_BED_LEVELING."
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Unified Bed Leveling
|
||||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
#if ENABLED(DELTA)
|
||||
#error "AUTO_BED_LEVELING_UBL does not yet support DELTA printers."
|
||||
#elif DISABLED(NEWPANEL)
|
||||
#error "AUTO_BED_LEVELING_UBL requires an LCD controller."
|
||||
#elif UBL_MESH_NUM_X_POINTS > 15 || UBL_MESH_NUM_Y_POINTS > 15
|
||||
#error "UBL_MESH_NUM_X_POINTS and UBL_MESH_NUM_Y_POINTS must be less than 16."
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
@ -434,6 +452,7 @@ static_assert(1 >= 0
|
||||
, "Please enable only one probe: PROBE_MANUALLY, FIX_MOUNTED_PROBE, Z Servo, BLTOUCH, Z_PROBE_ALLEN_KEY, or Z_PROBE_SLED."
|
||||
);
|
||||
|
||||
|
||||
#if PROBE_SELECTED
|
||||
|
||||
/**
|
||||
@ -577,21 +596,26 @@ static_assert(1 >= 0
|
||||
#endif
|
||||
#endif
|
||||
#else // !ABL_GRID
|
||||
|
||||
// Check the triangulation points
|
||||
#if ABL_PROBE_PT_1_X < MIN_PROBE_X || ABL_PROBE_PT_1_X > MAX_PROBE_X
|
||||
#error "The given ABL_PROBE_PT_1_X can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_2_X < MIN_PROBE_X || ABL_PROBE_PT_2_X > MAX_PROBE_X
|
||||
#error "The given ABL_PROBE_PT_2_X can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_3_X < MIN_PROBE_X || ABL_PROBE_PT_3_X > MAX_PROBE_X
|
||||
#error "The given ABL_PROBE_PT_3_X can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_1_Y < MIN_PROBE_Y || ABL_PROBE_PT_1_Y > MAX_PROBE_Y
|
||||
#error "The given ABL_PROBE_PT_1_Y can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_2_Y < MIN_PROBE_Y || ABL_PROBE_PT_2_Y > MAX_PROBE_Y
|
||||
#error "The given ABL_PROBE_PT_2_Y can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_3_Y < MIN_PROBE_Y || ABL_PROBE_PT_3_Y > MAX_PROBE_Y
|
||||
#error "The given ABL_PROBE_PT_3_Y can't be reached by the Z probe."
|
||||
#endif
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
#ifndef EEPROM_SETTINGS
|
||||
#error "AUTO_BED_LEVELING_UBL requires EEPROM_SETTINGS. Please update your configuration."
|
||||
#endif
|
||||
#else // !UBL
|
||||
// Check the triangulation points
|
||||
#if ABL_PROBE_PT_1_X < MIN_PROBE_X || ABL_PROBE_PT_1_X > MAX_PROBE_X
|
||||
#error "The given ABL_PROBE_PT_1_X can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_2_X < MIN_PROBE_X || ABL_PROBE_PT_2_X > MAX_PROBE_X
|
||||
#error "The given ABL_PROBE_PT_2_X can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_3_X < MIN_PROBE_X || ABL_PROBE_PT_3_X > MAX_PROBE_X
|
||||
#error "The given ABL_PROBE_PT_3_X can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_1_Y < MIN_PROBE_Y || ABL_PROBE_PT_1_Y > MAX_PROBE_Y
|
||||
#error "The given ABL_PROBE_PT_1_Y can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_2_Y < MIN_PROBE_Y || ABL_PROBE_PT_2_Y > MAX_PROBE_Y
|
||||
#error "The given ABL_PROBE_PT_2_Y can't be reached by the Z probe."
|
||||
#elif ABL_PROBE_PT_3_Y < MIN_PROBE_Y || ABL_PROBE_PT_3_Y > MAX_PROBE_Y
|
||||
#error "The given ABL_PROBE_PT_3_Y can't be reached by the Z probe."
|
||||
#endif
|
||||
#endif // !AUTO_BED_LEVEING_UBL
|
||||
|
||||
#endif // !ABL_GRID
|
||||
|
||||
|
Reference in New Issue