Sensor 502 and PTC cleanup
This commit is contained in:
		| @@ -373,6 +373,7 @@ | ||||
|  *     4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! | ||||
|  *     5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan, J-Head, and E3D) (4.7k pullup) | ||||
|  *   501 : 100K Zonestar (Tronxy X3A) Thermistor | ||||
|  *   502 : 100K Zonestar Thermistor used by hot bed in Zonestar Prusa P802M | ||||
|  *   512 : 100k RPW-Ultra hotend thermistor (4.7k pullup) | ||||
|  *     6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) | ||||
|  *     7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) | ||||
|   | ||||
| @@ -1666,33 +1666,33 @@ | ||||
|     // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START | ||||
|     // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. | ||||
|  | ||||
|     // #define PTC_SAMPLE_START  30.0f | ||||
|     // #define PTC_SAMPLE_RES    5.0f | ||||
|     // #define PTC_SAMPLE_COUNT  10U | ||||
|     //#define PTC_SAMPLE_START  30.0f | ||||
|     //#define PTC_SAMPLE_RES    5.0f | ||||
|     //#define PTC_SAMPLE_COUNT  10U | ||||
|  | ||||
|     // Bed temperature calibration builds a similar table. | ||||
|  | ||||
|     // #define BTC_SAMPLE_START  60.0f | ||||
|     // #define BTC_SAMPLE_RES    5.0f | ||||
|     // #define BTC_SAMPLE_COUNT  10U | ||||
|     //#define BTC_SAMPLE_START  60.0f | ||||
|     //#define BTC_SAMPLE_RES    5.0f | ||||
|     //#define BTC_SAMPLE_COUNT  10U | ||||
|  | ||||
|     // The temperature the probe should be at while taking measurements during bed temperature | ||||
|     // calibration. | ||||
|     // #define BTC_PROBE_TEMP 30.0f | ||||
|     //#define BTC_PROBE_TEMP 30.0f | ||||
|  | ||||
|     // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. | ||||
|     // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. | ||||
|     // #define PTC_PROBE_HEATING_OFFSET 0.5f | ||||
|     //#define PTC_PROBE_HEATING_OFFSET 0.5f | ||||
|  | ||||
|     // Height to raise the Z-probe between heating and taking the next measurement. Some probes | ||||
|     // may fail to untrigger if they have been triggered for a long time, which can be solved by | ||||
|     // increasing the height the probe is raised to. | ||||
|     // #define PTC_PROBE_RAISE 15U | ||||
|     //#define PTC_PROBE_RAISE 15U | ||||
|  | ||||
|     // If the probe is outside of the defined range, use linear extrapolation using the closest | ||||
|     // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] | ||||
|     // and data[4] to perform linear extrapolation for values below PTC_SAMPLE_START. | ||||
|     // #define PTC_LINEAR_EXTRAPOLATION 4 | ||||
|     //#define PTC_LINEAR_EXTRAPOLATION 4 | ||||
|   #endif | ||||
| #endif | ||||
|  | ||||
|   | ||||
		Reference in New Issue
	
	Block a user