Sensor 502 and PTC cleanup
This commit is contained in:
parent
51be595573
commit
caeba33d28
@ -373,6 +373,7 @@
|
||||
* 4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !!
|
||||
* 5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan, J-Head, and E3D) (4.7k pullup)
|
||||
* 501 : 100K Zonestar (Tronxy X3A) Thermistor
|
||||
* 502 : 100K Zonestar Thermistor used by hot bed in Zonestar Prusa P802M
|
||||
* 512 : 100k RPW-Ultra hotend thermistor (4.7k pullup)
|
||||
* 6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup)
|
||||
* 7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup)
|
||||
|
@ -1666,33 +1666,33 @@
|
||||
// Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START
|
||||
// (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples.
|
||||
|
||||
// #define PTC_SAMPLE_START 30.0f
|
||||
// #define PTC_SAMPLE_RES 5.0f
|
||||
// #define PTC_SAMPLE_COUNT 10U
|
||||
//#define PTC_SAMPLE_START 30.0f
|
||||
//#define PTC_SAMPLE_RES 5.0f
|
||||
//#define PTC_SAMPLE_COUNT 10U
|
||||
|
||||
// Bed temperature calibration builds a similar table.
|
||||
|
||||
// #define BTC_SAMPLE_START 60.0f
|
||||
// #define BTC_SAMPLE_RES 5.0f
|
||||
// #define BTC_SAMPLE_COUNT 10U
|
||||
//#define BTC_SAMPLE_START 60.0f
|
||||
//#define BTC_SAMPLE_RES 5.0f
|
||||
//#define BTC_SAMPLE_COUNT 10U
|
||||
|
||||
// The temperature the probe should be at while taking measurements during bed temperature
|
||||
// calibration.
|
||||
// #define BTC_PROBE_TEMP 30.0f
|
||||
//#define BTC_PROBE_TEMP 30.0f
|
||||
|
||||
// Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster.
|
||||
// Note: the Z=0.0f offset is determined by the probe offset which can be set using M851.
|
||||
// #define PTC_PROBE_HEATING_OFFSET 0.5f
|
||||
//#define PTC_PROBE_HEATING_OFFSET 0.5f
|
||||
|
||||
// Height to raise the Z-probe between heating and taking the next measurement. Some probes
|
||||
// may fail to untrigger if they have been triggered for a long time, which can be solved by
|
||||
// increasing the height the probe is raised to.
|
||||
// #define PTC_PROBE_RAISE 15U
|
||||
//#define PTC_PROBE_RAISE 15U
|
||||
|
||||
// If the probe is outside of the defined range, use linear extrapolation using the closest
|
||||
// point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0]
|
||||
// and data[4] to perform linear extrapolation for values below PTC_SAMPLE_START.
|
||||
// #define PTC_LINEAR_EXTRAPOLATION 4
|
||||
//#define PTC_LINEAR_EXTRAPOLATION 4
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user