Update Marlin/Configuration.h
This commit is contained in:
		| @@ -38,19 +38,25 @@ | |||||||
| //=========================================================================== | //=========================================================================== | ||||||
| //=============================Thermal Settings  ============================ | //=============================Thermal Settings  ============================ | ||||||
| //=========================================================================== | //=========================================================================== | ||||||
|  | // | ||||||
|  | //--NORMAL IS 4.7kohm PULLUP!-- 1kohm pullup can be used on hotend sensor, using correct resistor and table | ||||||
|  | // | ||||||
| //// Temperature sensor settings: | //// Temperature sensor settings: | ||||||
| // -2 is thermocouple with MAX6675 (only for sensor 0) | // -2 is thermocouple with MAX6675 (only for sensor 0) | ||||||
| // -1 is thermocouple with AD595 | // -1 is thermocouple with AD595 | ||||||
| // 0 is not used | // 0 is not used | ||||||
| // 1 is 100k thermistor - best choice for EPCOS 100k | // 1 is 100k thermistor - best choice for EPCOS 100k (4.7k pullup) | ||||||
| // 2 is 200k thermistor | // 2 is 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup) | ||||||
| // 3 is mendel-parts thermistor | // 3 is mendel-parts thermistor (4.7k pullup) | ||||||
| // 4 is 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! | // 4 is 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !! | ||||||
| // 5 is ParCan supplied 104GT-2 100K | // 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan) (4.7k pullup) | ||||||
| // 6 is EPCOS 100k - Not as accurate as table 1 (created using a fluke thermocouple) | // 6 is 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) | ||||||
| // 7 is 100k Honeywell thermistor 135-104LAG-J01 | // 7 is 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) | ||||||
| // 8 is EPCOS 100k - 1Kohm RESISTOR PULLUP ONLY! SEE therm table, should give twice resolution from 150C to 200C - EXPERIMENTAL! | // | ||||||
|  | //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k  | ||||||
|  | //                          (but gives greater accuracy and more stable PID) | ||||||
|  | // 51 is 100k thermistor - EPCOS (1k pullup) | ||||||
|  | // 52 is 200k thermistor - ATC Semitec 204GT-2 (1k pullup) | ||||||
|  |  | ||||||
| #define TEMP_SENSOR_0 -1 | #define TEMP_SENSOR_0 -1 | ||||||
| #define TEMP_SENSOR_1 0 | #define TEMP_SENSOR_1 0 | ||||||
|   | |||||||