Update Marlin/Configuration.h
This commit is contained in:
parent
dd9144994e
commit
c4490f5f3d
@ -38,19 +38,25 @@
|
|||||||
//===========================================================================
|
//===========================================================================
|
||||||
//=============================Thermal Settings ============================
|
//=============================Thermal Settings ============================
|
||||||
//===========================================================================
|
//===========================================================================
|
||||||
|
//
|
||||||
|
//--NORMAL IS 4.7kohm PULLUP!-- 1kohm pullup can be used on hotend sensor, using correct resistor and table
|
||||||
|
//
|
||||||
//// Temperature sensor settings:
|
//// Temperature sensor settings:
|
||||||
// -2 is thermocouple with MAX6675 (only for sensor 0)
|
// -2 is thermocouple with MAX6675 (only for sensor 0)
|
||||||
// -1 is thermocouple with AD595
|
// -1 is thermocouple with AD595
|
||||||
// 0 is not used
|
// 0 is not used
|
||||||
// 1 is 100k thermistor - best choice for EPCOS 100k
|
// 1 is 100k thermistor - best choice for EPCOS 100k (4.7k pullup)
|
||||||
// 2 is 200k thermistor
|
// 2 is 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup)
|
||||||
// 3 is mendel-parts thermistor
|
// 3 is mendel-parts thermistor (4.7k pullup)
|
||||||
// 4 is 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !!
|
// 4 is 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !!
|
||||||
// 5 is ParCan supplied 104GT-2 100K
|
// 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan) (4.7k pullup)
|
||||||
// 6 is EPCOS 100k - Not as accurate as table 1 (created using a fluke thermocouple)
|
// 6 is 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup)
|
||||||
// 7 is 100k Honeywell thermistor 135-104LAG-J01
|
// 7 is 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup)
|
||||||
// 8 is EPCOS 100k - 1Kohm RESISTOR PULLUP ONLY! SEE therm table, should give twice resolution from 150C to 200C - EXPERIMENTAL!
|
//
|
||||||
|
// 1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
|
||||||
|
// (but gives greater accuracy and more stable PID)
|
||||||
|
// 51 is 100k thermistor - EPCOS (1k pullup)
|
||||||
|
// 52 is 200k thermistor - ATC Semitec 204GT-2 (1k pullup)
|
||||||
|
|
||||||
#define TEMP_SENSOR_0 -1
|
#define TEMP_SENSOR_0 -1
|
||||||
#define TEMP_SENSOR_1 0
|
#define TEMP_SENSOR_1 0
|
||||||
|
Loading…
Reference in New Issue
Block a user