Merge pull request #4165 from thinkyhead/rc_rumba_temp_pins
Always define temp sensor, heater pins for RUMBA
This commit is contained in:
commit
bf216bd78f
@ -1138,7 +1138,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1137,7 +1137,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
#define TEMP_STAT_LEDS
|
#define TEMP_STAT_LEDS
|
||||||
|
@ -1121,7 +1121,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1119,7 +1119,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1130,7 +1130,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1132,7 +1132,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1155,7 +1155,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1138,7 +1138,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1138,7 +1138,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1146,7 +1146,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1159,7 +1159,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1130,7 +1130,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1138,7 +1138,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1223,7 +1223,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1217,7 +1217,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1220,7 +1220,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1220,7 +1220,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1222,7 +1222,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1141,7 +1141,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -1132,7 +1132,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
|
|||||||
// at zero value, there are 128 effective control positions.
|
// at zero value, there are 128 effective control positions.
|
||||||
#define SOFT_PWM_SCALE 0
|
#define SOFT_PWM_SCALE 0
|
||||||
|
|
||||||
// Temperature status LEDs that display the hotend and bet temperature.
|
// Temperature status LEDs that display the hotend and bed temperature.
|
||||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||||
//#define TEMP_STAT_LEDS
|
//#define TEMP_STAT_LEDS
|
||||||
|
@ -8,101 +8,96 @@
|
|||||||
|
|
||||||
//#define LARGE_FLASH true
|
//#define LARGE_FLASH true
|
||||||
|
|
||||||
#define X_ENABLE_PIN 26
|
#define X_ENABLE_PIN 26
|
||||||
#define X_STEP_PIN 25
|
#define X_STEP_PIN 25
|
||||||
#define X_DIR_PIN 27
|
#define X_DIR_PIN 27
|
||||||
#define X_MIN_PIN 19
|
#define X_MIN_PIN 19
|
||||||
#define X_MAX_PIN -1
|
#define X_MAX_PIN -1
|
||||||
|
|
||||||
#define Y_ENABLE_PIN 29
|
#define Y_ENABLE_PIN 29
|
||||||
#define Y_STEP_PIN 28
|
#define Y_STEP_PIN 28
|
||||||
#define Y_DIR_PIN 30
|
#define Y_DIR_PIN 30
|
||||||
#define Y_MIN_PIN 22
|
#define Y_MIN_PIN 22
|
||||||
#define Y_MAX_PIN -1
|
#define Y_MAX_PIN -1
|
||||||
|
|
||||||
#define Z_ENABLE_PIN 32
|
#define Z_ENABLE_PIN 32
|
||||||
#define Z_STEP_PIN 31
|
#define Z_STEP_PIN 31
|
||||||
#define Z_DIR_PIN 33
|
#define Z_DIR_PIN 33
|
||||||
#define Z_MIN_PIN 23
|
#define Z_MIN_PIN 23
|
||||||
#define Z_MAX_PIN -1
|
#define Z_MAX_PIN -1
|
||||||
|
|
||||||
|
#define E0_ENABLE_PIN 58
|
||||||
|
#define E0_STEP_PIN 57
|
||||||
|
#define E0_DIR_PIN 55
|
||||||
|
#define HEATER_0_PIN 11
|
||||||
|
#define TEMP_0_PIN 0 // ANALOG INPUT !!
|
||||||
|
|
||||||
//Tools
|
#define E1_ENABLE_PIN 60
|
||||||
|
#define E1_STEP_PIN 61
|
||||||
|
#define E1_DIR_PIN 62
|
||||||
|
#define HEATER_1_PIN 9
|
||||||
|
#define TEMP_1_PIN 9 // 9 for tool3 -> 13 for chambertemp
|
||||||
|
|
||||||
#define E0_ENABLE_PIN 58
|
#define E2_ENABLE_PIN 44
|
||||||
#define E0_STEP_PIN 57
|
#define E2_STEP_PIN 46
|
||||||
#define E0_DIR_PIN 55
|
#define E2_DIR_PIN 66
|
||||||
#define HEATER_0_PIN 11
|
#define HEATER_2_PIN 6
|
||||||
#define TEMP_0_PIN 0 // ANALOG INPUT !!
|
#define TEMP_2_PIN 13 // 10 for tool3 -> 13 for chambertemp
|
||||||
// #define TOOL_0_PIN 56
|
|
||||||
// #define TOOL_0_PWM_PIN 10 // used for red warning led at dual extruder
|
|
||||||
|
|
||||||
#define E1_ENABLE_PIN 60
|
#define E3_ENABLE_PIN 47
|
||||||
#define E1_STEP_PIN 61
|
#define E3_STEP_PIN 45
|
||||||
#define E1_DIR_PIN 62
|
#define E3_DIR_PIN 69
|
||||||
#define HEATER_1_PIN 9
|
#define HEATER_3_PIN 3
|
||||||
#define TEMP_1_PIN 9 // 9 for tool3 -> 13 for chambertemp
|
#define TEMP_3_PIN 11 // 11 for tool4 -> 13 for chambertemp
|
||||||
// #define TOOL_1_PIN 59
|
|
||||||
// #define TOOL_1_PWM_PIN 8 // used for lights at dual extruder
|
|
||||||
|
|
||||||
#define E2_ENABLE_PIN 44
|
#define HEATER_BED_PIN 24
|
||||||
#define E2_STEP_PIN 46
|
#define TEMP_BED_PIN 14 // ANALOG INPUT !!
|
||||||
#define E2_DIR_PIN 66
|
|
||||||
#define HEATER_2_PIN 6
|
|
||||||
#define TEMP_2_PIN 13 // 10 for tool3 -> 13 for chambertemp
|
|
||||||
// #define TOOL_2_PIN 4
|
|
||||||
// #define TOOL_2_PWM_PIN 5
|
|
||||||
|
|
||||||
#define E3_ENABLE_PIN 47
|
// Tools
|
||||||
#define E3_STEP_PIN 45
|
|
||||||
#define E3_DIR_PIN 69
|
|
||||||
#define HEATER_3_PIN 3
|
|
||||||
#define TEMP_3_PIN 11 // 11 for tool4 -> 13 for chambertemp
|
|
||||||
// #define TOOL_3_PIN 14
|
|
||||||
// #define TOOL_3_PWM_PIN 2
|
|
||||||
|
|
||||||
#define HEATER_BED_PIN 24
|
//#define TOOL_0_PIN 56
|
||||||
#define TEMP_BED_PIN 14 // ANALOG INPUT !!
|
//#define TOOL_0_PWM_PIN 10 // red warning led at dual extruder
|
||||||
|
//#define TOOL_1_PIN 59
|
||||||
|
//#define TOOL_1_PWM_PIN 8 // lights at dual extruder
|
||||||
|
//#define TOOL_2_PIN 4
|
||||||
|
//#define TOOL_2_PWM_PIN 5
|
||||||
|
//#define TOOL_3_PIN 14
|
||||||
|
//#define TOOL_3_PWM_PIN 2
|
||||||
|
|
||||||
//common I/O
|
// Common I/O
|
||||||
|
|
||||||
//#define TEMP_CHAMBER_PIN 13 // ANALOG INPUT !!
|
//#define TEMP_CHAMBER_PIN 13 // ANALOG INPUT !!
|
||||||
#define FIL_RUNOUT_PIN 18
|
#define FIL_RUNOUT_PIN 18
|
||||||
//#define PWM_1_PIN 12
|
//#define PWM_1_PIN 12
|
||||||
//#define PWM_2_PIN 13
|
//#define PWM_2_PIN 13
|
||||||
//#define SPARE_IO 17
|
//#define SPARE_IO 17
|
||||||
#define FAN_PIN 5 // 5 is PWMtool3 -> 7 is common PWM pin for all tools
|
#define FAN_PIN 5 // 5 is PWMtool3 -> 7 is common PWM pin for all tools
|
||||||
|
|
||||||
|
// User interface
|
||||||
|
#define BEEPER_PIN 16
|
||||||
|
|
||||||
//user interface
|
// Pins for DOGM SPI LCD Support
|
||||||
|
#define DOGLCD_A0 39
|
||||||
|
#define DOGLCD_CS 35
|
||||||
|
#define DOGLCD_MOSI 48
|
||||||
|
#define DOGLCD_SCK 49
|
||||||
|
#define LCD_SCREEN_ROT_180
|
||||||
|
|
||||||
#define BEEPER_PIN 16
|
// The encoder and click button
|
||||||
|
#define BTN_EN1 36
|
||||||
|
#define BTN_EN2 34
|
||||||
|
#define BTN_ENC 38
|
||||||
|
|
||||||
// Pins for DOGM SPI LCD Support
|
// Hardware buttons for manual movement of XYZ
|
||||||
#define DOGLCD_A0 39
|
#define SHIFT_OUT 42
|
||||||
#define DOGLCD_CS 35
|
#define SHIFT_LD 41
|
||||||
#define DOGLCD_MOSI 48
|
#define SHIFT_CLK 40
|
||||||
#define DOGLCD_SCK 49
|
|
||||||
#define LCD_SCREEN_ROT_180
|
|
||||||
|
|
||||||
//The encoder and click button
|
|
||||||
#define BTN_EN1 36
|
|
||||||
#define BTN_EN2 34
|
|
||||||
#define BTN_ENC 38 //the click switch
|
|
||||||
|
|
||||||
//hardware buttons for manual movement of XYZ
|
|
||||||
#define SHIFT_OUT 42
|
|
||||||
#define SHIFT_LD 41
|
|
||||||
#define SHIFT_CLK 40
|
|
||||||
|
|
||||||
|
|
||||||
//#define UI1 43
|
|
||||||
//#define UI2 37
|
|
||||||
|
|
||||||
|
//#define UI1 43
|
||||||
|
//#define UI2 37
|
||||||
|
|
||||||
// Other
|
// Other
|
||||||
|
#define SDSS 53
|
||||||
#define SDSS 53
|
#define SD_DETECT_PIN 15
|
||||||
#define SD_DETECT_PIN 15
|
#define STAT_LED_BLUE -1
|
||||||
#define STAT_LED_BLUE -1
|
#define STAT_LED_RED 10 // TOOL_0_PWM_PIN
|
||||||
#define STAT_LED_RED 10 // TOOL_0_PWM_PIN
|
|
||||||
|
@ -77,43 +77,36 @@
|
|||||||
#define PS_ON_PIN 45
|
#define PS_ON_PIN 45
|
||||||
#define KILL_PIN 46
|
#define KILL_PIN 46
|
||||||
|
|
||||||
#if TEMP_SENSOR_0 != 0
|
#define HEATER_0_PIN 2 // EXTRUDER 1
|
||||||
#define HEATER_0_PIN 2 // EXTRUDER 1
|
#define HEATER_1_PIN 3 // EXTRUDER 2
|
||||||
#if TEMP_SENSOR_0 == -1
|
#define HEATER_2_PIN 6 // EXTRUDER 3
|
||||||
#define TEMP_0_PIN 6 // ANALOG NUMBERING - connector *K1* on RUMBA thermocouple ADD ON is used
|
|
||||||
#else
|
#if TEMP_SENSOR_0 == -1
|
||||||
#define TEMP_0_PIN 15 // ANALOG NUMBERING - default connector for thermistor *T0* on rumba board is used
|
#define TEMP_0_PIN 6 // ANALOG NUMBERING - connector *K1* on RUMBA thermocouple ADD ON is used
|
||||||
#endif
|
#else
|
||||||
|
#define TEMP_0_PIN 15 // ANALOG NUMBERING - default connector for thermistor *T0* on rumba board is used
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
#if TEMP_SENSOR_1 != 0
|
#if TEMP_SENSOR_1 == -1
|
||||||
#define HEATER_1_PIN 3 // EXTRUDER 2
|
#define TEMP_1_PIN 5 // ANALOG NUMBERING - connector *K2* on RUMBA thermocouple ADD ON is used
|
||||||
#if TEMP_SENSOR_1 == -1
|
#else
|
||||||
#define TEMP_1_PIN 5 // ANALOG NUMBERING - connector *K2* on RUMBA thermocouple ADD ON is used
|
#define TEMP_1_PIN 14 // ANALOG NUMBERING - default connector for thermistor *T1* on rumba board is used
|
||||||
#else
|
|
||||||
#define TEMP_1_PIN 14 // ANALOG NUMBERING - default connector for thermistor *T1* on rumba board is used
|
|
||||||
#endif
|
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
#if TEMP_SENSOR_2 != 0
|
#if TEMP_SENSOR_2 == -1
|
||||||
#define HEATER_2_PIN 6 // EXTRUDER 3
|
#define TEMP_2_PIN 7 // ANALOG NUMBERING - connector *K3* on RUMBA thermocouple ADD ON is used <-- this can not be used when TEMP_SENSOR_BED is defined as thermocouple
|
||||||
#if TEMP_SENSOR_2 == -1
|
#else
|
||||||
#define TEMP_2_PIN 7 // ANALOG NUMBERING - connector *K3* on RUMBA thermocouple ADD ON is used <-- this can not be used when TEMP_SENSOR_BED is defined as thermocouple
|
#define TEMP_2_PIN 13 // ANALOG NUMBERING - default connector for thermistor *T2* on rumba board is used
|
||||||
#else
|
|
||||||
#define TEMP_2_PIN 13 // ANALOG NUMBERING - default connector for thermistor *T2* on rumba board is used
|
|
||||||
#endif
|
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
//optional for extruder 4 or chamber: #define TEMP_X_PIN 12 // ANALOG NUMBERING - default connector for thermistor *T3* on rumba board is used
|
//optional for extruder 4 or chamber: #define TEMP_X_PIN 12 // ANALOG NUMBERING - default connector for thermistor *T3* on rumba board is used
|
||||||
//optional FAN1 can be used as 4th heater output: #define HEATER_3_PIN 8 // EXTRUDER 4
|
//optional FAN1 can be used as 4th heater output: #define HEATER_3_PIN 8 // EXTRUDER 4
|
||||||
|
|
||||||
#if TEMP_SENSOR_BED != 0
|
#define HEATER_BED_PIN 9 // BED
|
||||||
#define HEATER_BED_PIN 9 // BED
|
#if TEMP_SENSOR_BED == -1
|
||||||
#if TEMP_SENSOR_BED == -1
|
#define TEMP_BED_PIN 7 // ANALOG NUMBERING - connector *K3* on RUMBA thermocouple ADD ON is used <-- this can not be used when TEMP_SENSOR_2 is defined as thermocouple
|
||||||
#define TEMP_BED_PIN 7 // ANALOG NUMBERING - connector *K3* on RUMBA thermocouple ADD ON is used <-- this can not be used when TEMP_SENSOR_2 is defined as thermocouple
|
#else
|
||||||
#else
|
#define TEMP_BED_PIN 11 // ANALOG NUMBERING - default connector for thermistor *THB* on rumba board is used
|
||||||
#define TEMP_BED_PIN 11 // ANALOG NUMBERING - default connector for thermistor *THB* on rumba board is used
|
|
||||||
#endif
|
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
#define SDSS 53
|
#define SDSS 53
|
||||||
|
Loading…
Reference in New Issue