Fix Anycubic Kossel config (probe crash) (#11832)
This commit is contained in:
		
				
					committed by
					
						 Scott Lahteine
						Scott Lahteine
					
				
			
			
				
	
			
			
			
						parent
						
							66f83d33e6
						
					
				
				
					commit
					bc06406d7d
				
			| @@ -1017,8 +1017,8 @@ | ||||
|  *     But: `M851 Z+1` with a CLEARANCE of 2  =>  2mm from bed to nozzle. | ||||
|  */ | ||||
| #define Z_CLEARANCE_DEPLOY_PROBE   10 // Z Clearance for Deploy/Stow | ||||
| #define Z_CLEARANCE_BETWEEN_PROBES  5 // Z Clearance between probe points | ||||
| #define Z_CLEARANCE_MULTI_PROBE     5 // Z Clearance between multiple probes | ||||
| #define Z_CLEARANCE_BETWEEN_PROBES 25 // Z Clearance between probe points | ||||
| #define Z_CLEARANCE_MULTI_PROBE    25 // Z Clearance between multiple probes | ||||
| #define Z_AFTER_PROBING            30 // Z position after probing is done | ||||
|  | ||||
| #define Z_PROBE_LOW_POINT          -2 // Farthest distance below the trigger-point to go before stopping | ||||
|   | ||||
| @@ -237,7 +237,7 @@ | ||||
|  * Multiple extruders can be assigned to the same pin in which case | ||||
|  * the fan will turn on when any selected extruder is above the threshold. | ||||
|  */ | ||||
| #define E0_AUTO_FAN_PIN ORIG_E0_AUTO_FAN_PIN | ||||
| //#define E0_AUTO_FAN_PIN -1 | ||||
| #define E1_AUTO_FAN_PIN -1 | ||||
| #define E2_AUTO_FAN_PIN -1 | ||||
| #define E3_AUTO_FAN_PIN -1 | ||||
|   | ||||
| @@ -8,13 +8,14 @@ These configurations activate many of the new advanced features of the Marlin fi | ||||
|  | ||||
| **Important**: Before doing anything else after updating the firmware, go to `Configuration > Advanced Settings > Initialize EEPROM` to get rid of old configurations. | ||||
|  | ||||
| Then you should execute `Configuration > Delta Calibration > Set Delta Height` and also run `Configuration > Delta Configuration > Probe Z-offset` to verify the Probe offset. | ||||
|  | ||||
| After that you should connect the Z-Probe and start `Configuration > Delta Calibration > Auto Calibration`. When it's done don't forget to also do `Configuration > Delta Calibration > Store Settings` to make it permanent. | ||||
|  | ||||
| You should also do a `Motion > Bed Leveling > Level bed` followed by `Store Settings` to ensure a perfect leveling. | ||||
|  | ||||
| Please do a manual paper test (moving the nozzle slowly down to Z0 and checking with a piece of paper). If it's not perfect, use `Configuration > Advanced Settings > Probe Z Offset` to correct the difference and execute the calibration again. | ||||
|  | ||||
| **Also Important**: if you value your Z-Probe do NOT execute `Configuration > Delta Configuration > Probe Z-offset` - This can destroy the Z-Probe, see issue [#11337](https://github.com/MarlinFirmware/Marlin/issues/11337). | ||||
|  | ||||
| # Select the Configuration | ||||
|  | ||||
|   | ||||
		Reference in New Issue
	