Implements a nozzle cleaning pattern generator (G12)
This commit is contained in:
@ -787,6 +787,44 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
|
||||
#define PREHEAT_2_TEMP_BED 110
|
||||
#define PREHEAT_2_FAN_SPEED 0 // Value from 0 to 255
|
||||
|
||||
//
|
||||
// Clean Nozzle Feature -- EXPERIMENTAL
|
||||
//
|
||||
// When enabled allows the user to send G12 to start the nozzle cleaning
|
||||
// process, the G-Code accepts two parameters:
|
||||
// "P" for pattern selection
|
||||
// "S" for defining the number of strokes/repetitions
|
||||
//
|
||||
// Available list of patterns:
|
||||
// P0: This is the default pattern, this process requires a sponge type
|
||||
// material at a fixed bed location, the cleaning process is based on
|
||||
// "strokes" i.e. back-and-forth movements between the starting and end
|
||||
// points.
|
||||
//
|
||||
// P1: This starts a zig-zag pattern between (Xs, Ys) and (Xe, Ye), "S"
|
||||
// defines the number of zig-zag triangles to be done. Each "side"
|
||||
// cannot be less than 5mm. As an example "G12 P1 S3" will execute:
|
||||
//
|
||||
// /| /| /| (Xe, Ye)
|
||||
// / | / | / |
|
||||
// / | / | / |
|
||||
// (Xs, Ys) / |/ |/ |
|
||||
//
|
||||
//
|
||||
// Caveats: End point Z should use the same value as Start point Z.
|
||||
//
|
||||
// Attention: This is an EXPERIMENTAL feature, in the future the G-code arguments
|
||||
// may change to add new functionality like different wipe patterns.
|
||||
//
|
||||
//#define CLEAN_NOZZLE_FEATURE
|
||||
|
||||
#if ENABLED(CLEAN_NOZZLE_FEATURE)
|
||||
#define CLEAN_NOZZLE_STROKES 12
|
||||
#define CLEAN_NOZZLE_START_PT { 30, 30, (Z_MIN_POS + 1), 0}
|
||||
#define CLEAN_NOZZLE_END_PT {100, 60, (Z_MIN_POS + 1), 0}
|
||||
// { X, Y, Z, E}
|
||||
#endif
|
||||
|
||||
//
|
||||
// Print job timer
|
||||
//
|
||||
|
Reference in New Issue
Block a user