PROBE_DOUBLE_TOUCH => MULTIPLE_PROBING

This commit is contained in:
Scott Lahteine
2017-12-07 16:33:51 -06:00
parent d7800e7975
commit ae663a4198
5 changed files with 56 additions and 20 deletions

View File

@ -690,14 +690,16 @@
// X and Y axis travel speed (mm/m) between probes
#define XY_PROBE_SPEED 8000
// Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH)
// Speed for the first approach when double-probing (MULTIPLE_PROBING == 2)
#define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z
// Speed for the "accurate" probe of each point
#define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2)
// Use double touch for probing
//#define PROBE_DOUBLE_TOUCH
// The number of probes to perform at each point.
// Set to 2 for a fast/slow probe, using the second probe result.
// Set to 3 or more for slow probes, averaging the results.
//#define MULTIPLE_PROBING 2
/**
* Z probes require clearance when deploying, stowing, and moving between