updated examples
This commit is contained in:
@ -292,6 +292,43 @@
|
||||
#define EXTRUDE_MINTEMP 150
|
||||
#define EXTRUDE_MAXLENGTH (X_MAX_LENGTH+Y_MAX_LENGTH) //prevent extrusion of very large distances.
|
||||
|
||||
/*================== Thermal Runaway Protection ==============================
|
||||
This is a feature to protect your printer from burn up in flames if it has
|
||||
a thermistor coming off place (this happened to a friend of mine recently and
|
||||
motivated me writing this feature).
|
||||
|
||||
The issue: If a thermistor come off, it will read a lower temperature than actual.
|
||||
The system will turn the heater on forever, burning up the filament and anything
|
||||
else around.
|
||||
|
||||
After the temperature reaches the target for the first time, this feature will
|
||||
start measuring for how long the current temperature stays below the target
|
||||
minus _HYSTERESIS (set_temperature - THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).
|
||||
|
||||
If it stays longer than _PERIOD, it means the thermistor temperature
|
||||
cannot catch up with the target, so something *may be* wrong. Then, to be on the
|
||||
safe side, the system will he halt.
|
||||
|
||||
Bear in mind the count down will just start AFTER the first time the
|
||||
thermistor temperature is over the target, so you will have no problem if
|
||||
your extruder heater takes 2 minutes to hit the target on heating.
|
||||
|
||||
*/
|
||||
// If you want to enable this feature for all your extruder heaters,
|
||||
// uncomment the 2 defines below:
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
//#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 //in seconds
|
||||
//#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// If you want to enable this feature for your bed heater,
|
||||
// uncomment the 2 defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
//#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 //in seconds
|
||||
//#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
//===========================================================================
|
||||
|
||||
//===========================================================================
|
||||
//=============================Mechanical Settings===========================
|
||||
//===========================================================================
|
||||
|
Reference in New Issue
Block a user