Fix usage, commentary of MANUAL_PROBE_START_Z, Z_AFTER_PROBING (#21692)
Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
This commit is contained in:
@ -788,14 +788,6 @@
|
||||
#endif
|
||||
#endif // FILAMENT_RUNOUT_SENSOR
|
||||
|
||||
#if EITHER(MESH_BED_LEVELING, AUTO_BED_LEVELING_UBL)
|
||||
#undef PROBE_MANUALLY
|
||||
#endif
|
||||
|
||||
#if ANY(HAS_BED_PROBE, PROBE_MANUALLY, MESH_BED_LEVELING)
|
||||
#define PROBE_SELECTED 1
|
||||
#endif
|
||||
|
||||
#if HAS_BED_PROBE
|
||||
#if DISABLED(NOZZLE_AS_PROBE)
|
||||
#define HAS_PROBE_XY_OFFSET 1
|
||||
@ -865,14 +857,16 @@
|
||||
#define PLANNER_LEVELING 1
|
||||
#endif
|
||||
#endif
|
||||
#if EITHER(HAS_ABL_OR_UBL, Z_MIN_PROBE_REPEATABILITY_TEST)
|
||||
#define HAS_PROBING_PROCEDURE 1
|
||||
#endif
|
||||
#if !HAS_LEVELING
|
||||
#undef PROBE_MANUALLY
|
||||
#undef RESTORE_LEVELING_AFTER_G28
|
||||
#undef ENABLE_LEVELING_AFTER_G28
|
||||
#endif
|
||||
#if !HAS_LEVELING || EITHER(MESH_BED_LEVELING, AUTO_BED_LEVELING_UBL)
|
||||
#undef PROBE_MANUALLY
|
||||
#endif
|
||||
#if ANY(HAS_BED_PROBE, PROBE_MANUALLY, MESH_BED_LEVELING)
|
||||
#define PROBE_SELECTED 1
|
||||
#endif
|
||||
|
||||
#ifdef GRID_MAX_POINTS_X
|
||||
#define GRID_MAX_POINTS ((GRID_MAX_POINTS_X) * (GRID_MAX_POINTS_Y))
|
||||
|
@ -2910,9 +2910,9 @@
|
||||
#define Z_CLEARANCE_BETWEEN_PROBES Z_HOMING_HEIGHT
|
||||
#endif
|
||||
#if Z_CLEARANCE_BETWEEN_PROBES > Z_HOMING_HEIGHT
|
||||
#define MANUAL_PROBE_HEIGHT Z_CLEARANCE_BETWEEN_PROBES
|
||||
#define Z_CLEARANCE_BETWEEN_MANUAL_PROBES Z_CLEARANCE_BETWEEN_PROBES
|
||||
#else
|
||||
#define MANUAL_PROBE_HEIGHT Z_HOMING_HEIGHT
|
||||
#define Z_CLEARANCE_BETWEEN_MANUAL_PROBES Z_HOMING_HEIGHT
|
||||
#endif
|
||||
#ifndef Z_CLEARANCE_MULTI_PROBE
|
||||
#define Z_CLEARANCE_MULTI_PROBE Z_CLEARANCE_BETWEEN_PROBES
|
||||
@ -2922,8 +2922,14 @@
|
||||
#endif
|
||||
#endif
|
||||
|
||||
#if !defined(MANUAL_PROBE_START_Z) && defined(Z_CLEARANCE_BETWEEN_PROBES)
|
||||
#define MANUAL_PROBE_START_Z Z_CLEARANCE_BETWEEN_PROBES
|
||||
// Define a starting height for measuring manual probe points
|
||||
#ifndef MANUAL_PROBE_START_Z
|
||||
#if EITHER(MESH_BED_LEVELING, PROBE_MANUALLY)
|
||||
// Leave MANUAL_PROBE_START_Z undefined so the prior Z height will be used.
|
||||
// Note: If Z_CLEARANCE_BETWEEN_MANUAL_PROBES is 0 there will be no raise between points
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL) && defined(Z_CLEARANCE_BETWEEN_PROBES)
|
||||
#define MANUAL_PROBE_START_Z Z_CLEARANCE_BETWEEN_PROBES
|
||||
#endif
|
||||
#endif
|
||||
|
||||
#ifndef __SAM3X8E__ //todo: hal: broken hal encapsulation
|
||||
|
Reference in New Issue
Block a user