@ -231,7 +231,7 @@
|
||||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
@ -590,6 +590,11 @@
|
||||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
@ -834,7 +839,6 @@
|
||||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
@ -972,15 +976,19 @@
|
||||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
@ -1527,13 +1535,13 @@
|
||||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
Reference in New Issue