Merge pull request #4455 from AnHardt/double-bump-feature
double bump probing as a feature
This commit is contained in:
		| @@ -482,10 +482,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -2110,16 +2110,21 @@ static void clean_up_after_endstop_or_probe_move() { | ||||
|       planner.bed_level_matrix.set_to_identity(); | ||||
|     #endif | ||||
|  | ||||
|     do_blocking_move_to_z(-(Z_MAX_LENGTH + 10), Z_PROBE_SPEED_FAST); | ||||
|     endstops.hit_on_purpose(); | ||||
|     set_current_from_steppers_for_axis(Z_AXIS); | ||||
|     SYNC_PLAN_POSITION_KINEMATIC(); | ||||
|     #if ENABLED(PROBE_DOUBLE_TOUCH) | ||||
|       do_blocking_move_to_z(-(Z_MAX_LENGTH + 10), Z_PROBE_SPEED_FAST); | ||||
|       endstops.hit_on_purpose(); | ||||
|       set_current_from_steppers_for_axis(Z_AXIS); | ||||
|       SYNC_PLAN_POSITION_KINEMATIC(); | ||||
|  | ||||
|     // move up the retract distance | ||||
|     do_blocking_move_to_z(current_position[Z_AXIS] + home_bump_mm(Z_AXIS), Z_PROBE_SPEED_FAST); | ||||
|       // move up the retract distance | ||||
|       do_blocking_move_to_z(current_position[Z_AXIS] + home_bump_mm(Z_AXIS), Z_PROBE_SPEED_FAST); | ||||
|     #else | ||||
|       // move fast, close to the bed | ||||
|       do_blocking_move_to_z(home_bump_mm(Z_AXIS), Z_PROBE_SPEED_FAST); | ||||
|     #endif | ||||
|  | ||||
|     // move back down slowly to find bed | ||||
|     do_blocking_move_to_z(current_position[Z_AXIS] - home_bump_mm(Z_AXIS) * 2, Z_PROBE_SPEED_SLOW); | ||||
|     // move down slowly to find bed | ||||
|     do_blocking_move_to_z(current_position[Z_AXIS] -2.0*home_bump_mm(Z_AXIS), Z_PROBE_SPEED_SLOW); | ||||
|     endstops.hit_on_purpose(); | ||||
|     set_current_from_steppers_for_axis(Z_AXIS); | ||||
|     SYNC_PLAN_POSITION_KINEMATIC(); | ||||
|   | ||||
| @@ -483,10 +483,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -465,10 +465,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -463,10 +463,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -475,10 +475,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -476,10 +476,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -500,10 +500,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -483,10 +483,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -483,10 +483,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -483,10 +483,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -480,10 +480,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -491,10 +491,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -504,10 +504,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -474,10 +474,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -483,10 +483,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -525,10 +525,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 4000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe | ||||
| // Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN. | ||||
|   | ||||
| @@ -525,10 +525,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 4000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe | ||||
| // Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN. | ||||
|   | ||||
| @@ -525,10 +525,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 4000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe | ||||
| // Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN. | ||||
|   | ||||
| @@ -516,10 +516,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe | ||||
| // Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN. | ||||
|   | ||||
| @@ -523,10 +523,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // Allen key retractable z-probe as seen on many Kossel delta printers - http://reprap.org/wiki/Kossel#Automatic_bed_leveling_probe | ||||
| // Deploys by touching z-axis belt. Retracts by pushing the probe down. Uses Z_MIN_PIN. | ||||
|   | ||||
| @@ -486,10 +486,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
| @@ -472,10 +472,12 @@ | ||||
|  | ||||
| // X and Y axis travel speed (mm/m) between probes | ||||
| #define XY_PROBE_SPEED 8000 | ||||
| // Speed for the first approach when probing | ||||
| // Speed for the first approach when double-probing (with PROBE_DOUBLE_TOUCH) | ||||
| #define Z_PROBE_SPEED_FAST HOMING_FEEDRATE_Z | ||||
| // Speed for the second approach when probing | ||||
| // Speed for the "accurate" probe of each point | ||||
| #define Z_PROBE_SPEED_SLOW (Z_PROBE_SPEED_FAST / 2) | ||||
| // Use double touch for probing | ||||
| //#define PROBE_DOUBLE_TOUCH | ||||
|  | ||||
| // | ||||
| // Allen Key Probe is defined in the Delta example configurations. | ||||
|   | ||||
		Reference in New Issue
	
	Block a user