Improve heating/cooling LCD messages (#10293)

This commit is contained in:
Marcio Teixeira 2018-04-04 17:29:27 -06:00 committed by Scott Lahteine
parent 21a47b50f4
commit 8bc93c6f2b
4 changed files with 53 additions and 31 deletions

View File

@ -72,7 +72,11 @@ void GcodeSuite::M104() {
#if ENABLED(ULTRA_LCD)
if (parser.value_celsius() > thermalManager.degHotend(e))
lcd_status_printf_P(0, PSTR("E%i %s"), e + 1, MSG_HEATING);
#if HOTENDS > 1
lcd_status_printf_P(0, PSTR("E%i " MSG_HEATING), e + 1);
#else
LCD_MESSAGEPGM("E " MSG_HEATING);
#endif
#endif
}
@ -127,8 +131,13 @@ void GcodeSuite::M109() {
#endif
#if ENABLED(ULTRA_LCD)
if (thermalManager.isHeatingHotend(target_extruder))
lcd_status_printf_P(0, PSTR("E%i %s"), target_extruder + 1, MSG_HEATING);
const bool heating = thermalManager.isHeatingHotend(target_extruder);
if (heating || !no_wait_for_cooling)
#if HOTENDS > 1
lcd_status_printf_P(0, heating ? PSTR("E%i " MSG_HEATING) : PSTR("E%i " MSG_COOLING), target_extruder + 1);
#else
lcd_setstatusPGM(heating ? PSTR("E " MSG_HEATING) : PSTR("E " MSG_COOLING));
#endif
#endif
}
else return;
@ -234,7 +243,7 @@ void GcodeSuite::M109() {
} while (wait_for_heatup && TEMP_CONDITIONS);
if (wait_for_heatup) {
LCD_MESSAGEPGM(MSG_HEATING_COMPLETE);
lcd_setstatusPGM(wants_to_cool ? PSTR(MSG_COOLING_COMPLETE) : PSTR(MSG_HEATING_COMPLETE));
#if ENABLED(PRINTER_EVENT_LEDS)
leds.set_white();
#endif

View File

@ -61,7 +61,6 @@ void GcodeSuite::M140() {
void GcodeSuite::M190() {
if (DEBUGGING(DRYRUN)) return;
LCD_MESSAGEPGM(MSG_BED_HEATING);
const bool no_wait_for_cooling = parser.seenval('S');
if (no_wait_for_cooling || parser.seenval('R')) {
thermalManager.setTargetBed(parser.value_celsius());
@ -72,6 +71,8 @@ void GcodeSuite::M190() {
}
else return;
lcd_setstatusPGM(thermalManager.isHeatingBed() ? PSTR(MSG_BED_HEATING) : PSTR(MSG_BED_COOLING));
#if TEMP_BED_RESIDENCY_TIME > 0
millis_t residency_start_ms = 0;
// Loop until the temperature has stabilized

View File

@ -783,6 +783,9 @@
#ifndef MSG_HEATING_FAILED_LCD
#define MSG_HEATING_FAILED_LCD _UxGT("Heating failed")
#endif
#ifndef MSG_HEATING_FAILED_LCD_BED
#define MSG_HEATING_FAILED_LCD_BED _UxGT("Bed heating failed")
#endif
#ifndef MSG_ERR_REDUNDANT_TEMP
#define MSG_ERR_REDUNDANT_TEMP _UxGT("Err: REDUNDANT TEMP")
#endif
@ -828,8 +831,17 @@
#ifndef MSG_HEATING_COMPLETE
#define MSG_HEATING_COMPLETE _UxGT("Heating done.")
#endif
#ifndef MSG_COOLING
#define MSG_COOLING _UxGT("Cooling...")
#endif
#ifndef MSG_COOLING_COMPLETE
#define MSG_COOLING_COMPLETE _UxGT("Cooling done.")
#endif
#ifndef MSG_BED_HEATING
#define MSG_BED_HEATING _UxGT("Bed Heating.")
#define MSG_BED_HEATING _UxGT("Bed heating.")
#endif
#ifndef MSG_BED_COOLING
#define MSG_BED_COOLING _UxGT("Bed cooling.")
#endif
#ifndef MSG_BED_DONE
#define MSG_BED_DONE _UxGT("Bed done.")

View File

@ -59,6 +59,24 @@
Temperature thermalManager;
/**
* Macros to include the heater id in temp errors. The compiler's dead-code
* elimination should (hopefully) optimize out the unused strings.
*/
#if HAS_TEMP_BED
#define _BED_ERR_PSTR(MSG, E) (E) == -1 ? PSTR(MSG ## _BED) :
#else
#define _BED_ERR_PSTR(MSG, E)
#endif
#define TEMP_ERR_PSTR(MSG, E) \
_BED_ERR_PSTR(MSG, E) \
(HOTENDS > 1 && (E) == 1) ? PSTR(MSG_E2 " " MSG) : \
(HOTENDS > 2 && (E) == 2) ? PSTR(MSG_E3 " " MSG) : \
(HOTENDS > 3 && (E) == 3) ? PSTR(MSG_E4 " " MSG) : \
(HOTENDS > 4 && (E) == 4) ? PSTR(MSG_E5 " " MSG) : \
PSTR(MSG_E1 " " MSG)
// public:
float Temperature::current_temperature[HOTENDS] = { 0.0 },
@ -447,12 +465,10 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
if (current > watch_temp_target) heated = true; // - Flag if target temperature reached
}
else if (ELAPSED(ms, temp_change_ms)) // Watch timer expired
_temp_error(hotend, PSTR(MSG_T_HEATING_FAILED), PSTR(MSG_HEATING_FAILED_LCD));
_temp_error(hotend, PSTR(MSG_T_HEATING_FAILED), TEMP_ERR_PSTR(MSG_HEATING_FAILED_LCD, hotend));
}
else if (current < target - (MAX_OVERSHOOT_PID_AUTOTUNE)) // Heated, then temperature fell too far?
_temp_error(hotend, PSTR(MSG_T_THERMAL_RUNAWAY),
hotend >= 0 ? PSTR(MSG_THERMAL_RUNAWAY) : PSTR(MSG_THERMAL_RUNAWAY_BED)
);
_temp_error(hotend, PSTR(MSG_T_THERMAL_RUNAWAY), TEMP_ERR_PSTR(MSG_THERMAL_RUNAWAY, hotend));
}
#endif
} // every 2 seconds
@ -591,24 +607,10 @@ void Temperature::_temp_error(const int8_t e, const char * const serial_msg, con
}
void Temperature::max_temp_error(const int8_t e) {
#if HAS_TEMP_BED
_temp_error(e, PSTR(MSG_T_MAXTEMP), e >= 0 ? PSTR(MSG_ERR_MAXTEMP) : PSTR(MSG_ERR_MAXTEMP_BED));
#else
_temp_error(HOTEND_INDEX, PSTR(MSG_T_MAXTEMP), PSTR(MSG_ERR_MAXTEMP));
#if HOTENDS == 1
UNUSED(e);
#endif
#endif
_temp_error(e, PSTR(MSG_T_MAXTEMP), TEMP_ERR_PSTR(MSG_ERR_MAXTEMP, e));
}
void Temperature::min_temp_error(const int8_t e) {
#if HAS_TEMP_BED
_temp_error(e, PSTR(MSG_T_MINTEMP), e >= 0 ? PSTR(MSG_ERR_MINTEMP) : PSTR(MSG_ERR_MINTEMP_BED));
#else
_temp_error(HOTEND_INDEX, PSTR(MSG_T_MINTEMP), PSTR(MSG_ERR_MINTEMP));
#if HOTENDS == 1
UNUSED(e);
#endif
#endif
_temp_error(e, PSTR(MSG_T_MINTEMP), TEMP_ERR_PSTR(MSG_ERR_MINTEMP, e));
}
float Temperature::get_pid_output(const int8_t e) {
@ -812,7 +814,7 @@ void Temperature::manage_heater() {
// Make sure temperature is increasing
if (watch_heater_next_ms[e] && ELAPSED(ms, watch_heater_next_ms[e])) { // Time to check this extruder?
if (degHotend(e) < watch_target_temp[e]) // Failed to increase enough?
_temp_error(e, PSTR(MSG_T_HEATING_FAILED), PSTR(MSG_HEATING_FAILED_LCD));
_temp_error(e, PSTR(MSG_T_HEATING_FAILED), TEMP_ERR_PSTR(MSG_HEATING_FAILED_LCD, e));
else // Start again if the target is still far off
start_watching_heater(e);
}
@ -850,7 +852,7 @@ void Temperature::manage_heater() {
// Make sure temperature is increasing
if (watch_bed_next_ms && ELAPSED(ms, watch_bed_next_ms)) { // Time to check the bed?
if (degBed() < watch_target_bed_temp) // Failed to increase enough?
_temp_error(-1, PSTR(MSG_T_HEATING_FAILED), PSTR(MSG_HEATING_FAILED_LCD));
_temp_error(-1, PSTR(MSG_T_HEATING_FAILED), TEMP_ERR_PSTR(MSG_HEATING_FAILED_LCD, -1));
else // Start again if the target is still far off
start_watching_bed();
}
@ -1453,9 +1455,7 @@ void Temperature::init() {
else if (PENDING(millis(), *timer)) break;
*state = TRRunaway;
case TRRunaway:
_temp_error(heater_id, PSTR(MSG_T_THERMAL_RUNAWAY),
heater_id >= 0 ? PSTR(MSG_THERMAL_RUNAWAY) : PSTR(MSG_THERMAL_RUNAWAY_BED)
);