Move and update heated chamber settings (#13671)
Co-Authored-By: the-real-orca <stephan.veigl@gmail.com>
This commit is contained in:
		| @@ -391,7 +391,6 @@ | ||||
| #define TEMP_SENSOR_5 0 | ||||
| #define TEMP_SENSOR_BED 5 | ||||
| #define TEMP_SENSOR_CHAMBER 0 | ||||
| #define CHAMBER_HEATER_PIN -1  // On/off pin for enclosure heating system | ||||
|  | ||||
| // Dummy thermistor constant temperature readings, for use with 998 and 999 | ||||
| #define DUMMY_THERMISTOR_998_VALUE 25 | ||||
| @@ -410,8 +409,6 @@ | ||||
| #define TEMP_BED_WINDOW          1  // (°C) Temperature proximity for the "temperature reached" timer | ||||
| #define TEMP_BED_HYSTERESIS      3  // (°C) Temperature proximity considered "close enough" to the target | ||||
|  | ||||
| #define TEMP_CHAMBER_HYSTERESIS  3  // (°C) Temperature proximity considered "close enough" to the target | ||||
|  | ||||
| // Below this temperature the heater will be switched off | ||||
| // because it probably indicates a broken thermistor wire. | ||||
| #define HEATER_0_MINTEMP   5 | ||||
| @@ -421,7 +418,6 @@ | ||||
| #define HEATER_4_MINTEMP   5 | ||||
| #define HEATER_5_MINTEMP   5 | ||||
| #define BED_MINTEMP        5 | ||||
| #define CHAMBER_MINTEMP    5 | ||||
|  | ||||
| // Above this temperature the heater will be switched off. | ||||
| // This can protect components from overheating, but NOT from shorts and failures. | ||||
| @@ -433,7 +429,6 @@ | ||||
| #define HEATER_4_MAXTEMP 275 | ||||
| #define HEATER_5_MAXTEMP 275 | ||||
| #define BED_MAXTEMP      150 | ||||
| #define CHAMBER_MAXTEMP  100 | ||||
|  | ||||
| //=========================================================================== | ||||
| //============================= PID Settings ================================ | ||||
| @@ -465,7 +460,7 @@ | ||||
| #endif // PIDTEMP | ||||
|  | ||||
| //=========================================================================== | ||||
| //============================= PID > Bed Temperature Control =============== | ||||
| //====================== PID > Bed Temperature Control ====================== | ||||
| //=========================================================================== | ||||
|  | ||||
| /** | ||||
|   | ||||
| @@ -50,6 +50,19 @@ | ||||
|   #define HEATER_BED_INVERTING true | ||||
| #endif | ||||
|  | ||||
| /** | ||||
|  * Heated Chamber settings | ||||
|  */ | ||||
| #if TEMP_SENSOR_CHAMBER | ||||
|   #define CHAMBER_MINTEMP             5 | ||||
|   #define CHAMBER_MAXTEMP            60 | ||||
|   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target | ||||
|   #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber | ||||
|   //#define CHAMBER_LIMIT_SWITCHING | ||||
|   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin | ||||
|   //#define HEATER_CHAMBER_INVERTING false | ||||
| #endif | ||||
|  | ||||
| #if DISABLED(PIDTEMPBED) | ||||
|   #define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control | ||||
|   #if ENABLED(BED_LIMIT_SWITCHING) | ||||
| @@ -127,8 +140,8 @@ | ||||
| #endif | ||||
|  | ||||
| #if ENABLED(PIDTEMP) | ||||
|   // this adds an experimental additional term to the heating power, proportional to the extrusion speed. | ||||
|   // if Kc is chosen well, the additional required power due to increased melting should be compensated. | ||||
|   // Add an experimental additional term to the heater power, proportional to the extrusion speed. | ||||
|   // A well-chosen Kc value should add just enough power to melt the increased material volume. | ||||
|   //#define PID_EXTRUSION_SCALING | ||||
|   #if ENABLED(PID_EXTRUSION_SCALING) | ||||
|     #define DEFAULT_Kc (100) //heating power=Kc*(e_speed) | ||||
|   | ||||
		Reference in New Issue
	