Move and update heated chamber settings (#13671)

Co-Authored-By: the-real-orca <stephan.veigl@gmail.com>
This commit is contained in:
Stephan
2019-04-12 22:38:10 +02:00
committed by Scott Lahteine
parent 62b4265410
commit 84273557f9
176 changed files with 1255 additions and 756 deletions

View File

@ -391,7 +391,6 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -410,8 +409,6 @@
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
// Below this temperature the heater will be switched off
// because it probably indicates a broken thermistor wire.
#define HEATER_0_MINTEMP 5
@ -421,7 +418,6 @@
#define HEATER_4_MINTEMP 5
#define HEATER_5_MINTEMP 5
#define BED_MINTEMP 5
#define CHAMBER_MINTEMP 5
// Above this temperature the heater will be switched off.
// This can protect components from overheating, but NOT from shorts and failures.
@ -433,7 +429,6 @@
#define HEATER_4_MAXTEMP 275
#define HEATER_5_MAXTEMP 275
#define BED_MAXTEMP 150
#define CHAMBER_MAXTEMP 100
//===========================================================================
//============================= PID Settings ================================
@ -476,7 +471,7 @@
#endif // PIDTEMP
//===========================================================================
//============================= PID > Bed Temperature Control ===============
//====================== PID > Bed Temperature Control ======================
//===========================================================================
/**

View File

@ -50,6 +50,19 @@
#define HEATER_BED_INVERTING true
#endif
/**
* Heated Chamber settings
*/
#if TEMP_SENSOR_CHAMBER
#define CHAMBER_MINTEMP 5
#define CHAMBER_MAXTEMP 60
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//#define CHAMBER_LIMIT_SWITCHING
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
//#define HEATER_CHAMBER_INVERTING false
#endif
#if DISABLED(PIDTEMPBED)
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
#if ENABLED(BED_LIMIT_SWITCHING)
@ -127,8 +140,8 @@
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
// A well-chosen Kc value should add just enough power to melt the increased material volume.
//#define PID_EXTRUSION_SCALING
#if ENABLED(PID_EXTRUSION_SCALING)
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)