Move and update heated chamber settings (#13671)

Co-Authored-By: the-real-orca <stephan.veigl@gmail.com>
This commit is contained in:
Stephan
2019-04-12 22:38:10 +02:00
committed by Scott Lahteine
parent 62b4265410
commit 84273557f9
176 changed files with 1255 additions and 756 deletions

View File

@ -50,6 +50,19 @@
#define HEATER_BED_INVERTING true
#endif
/**
* Heated Chamber settings
*/
#if TEMP_SENSOR_CHAMBER
#define CHAMBER_MINTEMP 5
#define CHAMBER_MAXTEMP 60
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//#define CHAMBER_LIMIT_SWITCHING
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
//#define HEATER_CHAMBER_INVERTING false
#endif
#if DISABLED(PIDTEMPBED)
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
#if ENABLED(BED_LIMIT_SWITCHING)
@ -127,8 +140,8 @@
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
// A well-chosen Kc value should add just enough power to melt the increased material volume.
//#define PID_EXTRUSION_SCALING
#if ENABLED(PID_EXTRUSION_SCALING)
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)