Move and update heated chamber settings (#13671)
Co-Authored-By: the-real-orca <stephan.veigl@gmail.com>
This commit is contained in:
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 7
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 250
|
||||
#define HEATER_5_MAXTEMP 250
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -485,7 +480,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 20
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -487,7 +482,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 11
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -487,7 +482,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -392,7 +392,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -411,8 +410,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -422,7 +419,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -434,7 +430,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -483,7 +478,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 13
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -54,6 +54,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -131,8 +144,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 115
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 60
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 115
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 260
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -399,7 +399,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -418,8 +417,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -429,7 +426,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -441,7 +437,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 100
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -477,7 +472,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 260
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -392,7 +392,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -411,8 +410,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -422,7 +419,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -434,7 +430,6 @@
|
||||
#define HEATER_4_MAXTEMP 415
|
||||
#define HEATER_5_MAXTEMP 415
|
||||
#define BED_MAXTEMP 165
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -477,7 +472,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -400,7 +400,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -419,8 +418,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -430,7 +427,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -442,7 +438,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -490,7 +485,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 75
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -393,7 +393,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -412,8 +411,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -423,7 +420,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -435,7 +431,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -484,7 +479,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -466,7 +461,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 245
|
||||
#define HEATER_5_MAXTEMP 245
|
||||
#define BED_MAXTEMP 115
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -436,7 +436,6 @@
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#endif
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -455,8 +454,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -465,7 +462,6 @@
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -480,7 +476,6 @@
|
||||
#else
|
||||
#define BED_MAXTEMP 100
|
||||
#endif
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -528,7 +523,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -406,7 +406,6 @@
|
||||
#endif
|
||||
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -425,8 +424,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -436,7 +433,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -448,7 +444,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -498,7 +493,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -400,7 +400,6 @@
|
||||
#endif
|
||||
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -419,8 +418,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -430,7 +427,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -442,7 +438,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -485,7 +480,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -466,7 +461,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -466,7 +461,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -396,7 +396,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1 // measured to be satisfactorily accurate on center of bed within +/- 1 degC.
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -415,8 +414,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -426,7 +423,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -438,7 +434,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -411,7 +411,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -430,8 +429,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -441,7 +438,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -453,7 +449,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -496,7 +491,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -399,7 +399,6 @@
|
||||
// The reasons are inconclusive so I leave at 1
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -418,8 +417,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -429,7 +426,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -441,7 +437,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -484,7 +479,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 11
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 100
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -475,7 +470,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -392,7 +392,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -411,8 +410,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -422,7 +419,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -434,7 +430,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -477,7 +472,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -392,7 +392,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -411,8 +410,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -422,7 +419,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -434,7 +430,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -477,7 +472,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 250
|
||||
#define HEATER_5_MAXTEMP 250
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1 // Sanguinololu v1.3 with 4.7kOhm pullup
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
Some files were not shown because too many files have changed in this diff Show More
Reference in New Issue