Chamber Fan mode 3 (#21594)

This commit is contained in:
Giuliano Zaro
2021-04-13 03:28:13 +02:00
committed by GitHub
parent 4044ed8783
commit 7f56538602
2 changed files with 6 additions and 1 deletions

View File

@ -1406,6 +1406,8 @@ void Temperature::manage_heater() {
fan_chamber_pwm = (CHAMBER_FAN_BASE) + (CHAMBER_FAN_FACTOR) * ABS(temp_chamber.celsius - temp_chamber.target);
if (temp_chamber.soft_pwm_amount)
fan_chamber_pwm += (CHAMBER_FAN_FACTOR) * 2;
#elif CHAMBER_FAN_MODE == 3
fan_chamber_pwm = CHAMBER_FAN_BASE + _MAX((CHAMBER_FAN_FACTOR) * (temp_chamber.celsius - temp_chamber.target), 0);
#endif
NOMORE(fan_chamber_pwm, 225);
set_fan_speed(2, fan_chamber_pwm); // TODO: instead of fan 2, set to chamber fan