Various minor spelling corrections

Redo of #2939 rebased against RCBugFix
This commit is contained in:
Scott Lahteine
2016-03-05 20:41:15 -08:00
parent 04a0d45c22
commit 772460a7b8
40 changed files with 272 additions and 272 deletions

View File

@ -248,13 +248,13 @@ Here are some standard links for getting your machine calibrated:
#define PID_BED_INTEGRAL_DRIVE_MAX MAX_BED_POWER //limit for the integral term
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
//120V 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
//from FOPDT model - kp=.39 Tp=405 Tdead=66, Tc set to 79.2, aggressive factor of .15 (vs .1, 1, 10)
#define DEFAULT_bedKp 10.00
#define DEFAULT_bedKi .023
#define DEFAULT_bedKd 305.4
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
//120V 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
//from pidautotune
//#define DEFAULT_bedKp 97.1
//#define DEFAULT_bedKi 1.41
@ -452,7 +452,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// This mode is preferred because there are more measurements.
//
// - "3-point" mode
// Probe 3 arbitrary points on the bed (that aren't colinear)
// Probe 3 arbitrary points on the bed (that aren't collinear)
// You specify the XY coordinates of all 3 points.
// Enable this to sample the bed in a grid (least squares solution).
@ -751,7 +751,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
// @section extras
// Increase the FAN pwm frequency. Removes the PWM noise but increases heating in the FET/Arduino
// Increase the FAN PWM frequency. Removes the PWM noise but increases heating in the FET/Arduino
//#define FAST_PWM_FAN
// Use software PWM to drive the fan, as for the heaters. This uses a very low frequency
@ -839,7 +839,7 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
#define DEFAULT_NOMINAL_FILAMENT_DIA 3.00 //Enter the diameter (in mm) of the filament generally used (3.0 mm or 1.75 mm) - this is then used in the slicer software. Used for sensor reading validation
#define MEASURED_UPPER_LIMIT 3.30 //upper limit factor used for sensor reading validation in mm
#define MEASURED_LOWER_LIMIT 1.90 //lower limit factor for sensor reading validation in mm
#define MAX_MEASUREMENT_DELAY 20 //delay buffer size in bytes (1 byte = 1cm)- limits maximum measurement delay allowable (must be larger than MEASUREMENT_DELAY_CM and lower number saves RAM)
#define MAX_MEASUREMENT_DELAY 20 //delay buffer size in bytes (1 byte = 1cm) - limits maximum measurement delay allowable (must be larger than MEASUREMENT_DELAY_CM and lower number saves RAM)
//defines used in the code
#define DEFAULT_MEASURED_FILAMENT_DIA DEFAULT_NOMINAL_FILAMENT_DIA //set measured to nominal initially