@ -302,23 +302,10 @@ Here are some standard links for getting your machine calibrated:
* The solution: Once the temperature reaches the target, start observing.
* If the temperature stays too far below the target (hysteresis) for too long,
* the firmware will halt as a safety precaution.
*
* Note that because the countdown starts only AFTER the temperature reaches
* the target, this will not catch a thermistor that is already disconnected
* when the print starts!
*
* To enable for all extruder heaters, uncomment the two defines below:
*/
// Parameters for all extruder heaters
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
// To enable for the bed heater, uncomment the two defines below:
// Parameters for the bed heater
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
//===========================================================================