Allow lcd_setstatusPGM to reset the alert level

This commit is contained in:
Scott Lahteine
2017-05-29 11:51:29 -05:00
parent 25114414cd
commit 6f89db11f0
4 changed files with 23 additions and 26 deletions

View File

@ -131,7 +131,7 @@
void set_destination_to_current();
void set_current_to_destination();
void prepare_move_to_destination();
void lcd_setstatuspgm(const char* const message, const uint8_t level);
void lcd_setstatusPGM(const char* const message, const int8_t level);
void sync_plan_position_e();
void chirp_at_user();
@ -181,18 +181,17 @@
safe_delay(10); // Wait for click to settle
#if ENABLED(ULTRA_LCD)
lcd_setstatuspgm(PSTR("Mesh Validation Stopped."), 99);
lcd_setstatusPGM(PSTR("Mesh Validation Stopped."), 99);
lcd_quick_feedback();
#endif
lcd_reset_alert_level();
while (!ubl_lcd_clicked()) idle(); // Wait for button release
// If the button is suddenly pressed again,
// ask the user to resolve the issue
lcd_setstatuspgm(PSTR("Release button"), 99); // will never appear...
lcd_setstatusPGM(PSTR("Release button"), 99); // will never appear...
while (ubl_lcd_clicked()) idle(); // unless this loop happens
lcd_setstatuspgm(PSTR(""));
lcd_setstatusPGM(PSTR(""), -1);
return true;
}
@ -351,8 +350,7 @@
} while (--g26_repeats && location.x_index >= 0 && location.y_index >= 0);
LEAVE:
lcd_reset_alert_level();
lcd_setstatuspgm(PSTR("Leaving G26"));
lcd_setstatusPGM(PSTR("Leaving G26"), -1);
retract_filament(destination);
destination[Z_AXIS] = Z_CLEARANCE_BETWEEN_PROBES;
@ -726,8 +724,7 @@
}
bool unified_bed_leveling::exit_from_g26() {
lcd_reset_alert_level();
lcd_setstatuspgm(PSTR("Leaving G26"));
lcd_setstatusPGM(PSTR("Leaving G26"), -1);
while (ubl_lcd_clicked()) idle();
return UBL_ERR;
}
@ -741,7 +738,7 @@
#if HAS_TEMP_BED
#if ENABLED(ULTRA_LCD)
if (g26_bed_temp > 25) {
lcd_setstatuspgm(PSTR("G26 Heating Bed."), 99);
lcd_setstatusPGM(PSTR("G26 Heating Bed."), 99);
lcd_quick_feedback();
#endif
has_control_of_lcd_panel = true;
@ -757,7 +754,7 @@
}
#if ENABLED(ULTRA_LCD)
}
lcd_setstatuspgm(PSTR("G26 Heating Nozzle."), 99);
lcd_setstatusPGM(PSTR("G26 Heating Nozzle."), 99);
lcd_quick_feedback();
#endif
#endif
@ -774,8 +771,7 @@
}
#if ENABLED(ULTRA_LCD)
lcd_reset_alert_level();
lcd_setstatuspgm(PSTR(""));
lcd_setstatusPGM(PSTR(""), -1);
lcd_quick_feedback();
#endif
@ -792,7 +788,7 @@
has_control_of_lcd_panel = true;
lcd_setstatuspgm(PSTR("User-Controlled Prime"), 99);
lcd_setstatusPGM(PSTR("User-Controlled Prime"), 99);
chirp_at_user();
set_destination_to_current();
@ -819,9 +815,9 @@
while (ubl_lcd_clicked()) idle(); // Debounce Encoder Wheel
#if ENABLED(ULTRA_LCD)
strcpy_P(lcd_status_message, PSTR("Done Priming")); // We can't do lcd_setstatuspgm() without having it continue;
strcpy_P(lcd_status_message, PSTR("Done Priming")); // We can't do lcd_setstatusPGM() without having it continue;
// So... We cheat to get a message up.
lcd_setstatuspgm(PSTR("Done Priming"), 99);
lcd_setstatusPGM(PSTR("Done Priming"), 99);
lcd_quick_feedback();
#endif
@ -830,7 +826,7 @@
}
else {
#if ENABLED(ULTRA_LCD)
lcd_setstatuspgm(PSTR("Fixed Length Prime."), 99);
lcd_setstatusPGM(PSTR("Fixed Length Prime."), 99);
lcd_quick_feedback();
#endif
set_destination_to_current();