Mesh bed leveling: Added G29 S3 + finer steps in manual probing.

* Use "G29 S3 Xn Yn Zn.nn" to modify bad probed point manually
* Changed manual Z steps from 0.05 to 0.025 and made brought it to Configuration.h
This commit is contained in:
Edward Patel
2015-04-01 21:18:51 +02:00
parent 443468df8d
commit 6b91b7b411
3 changed files with 52 additions and 10 deletions

View File

@ -1795,14 +1795,14 @@ static void _lcd_level_bed()
{
if (encoderPosition != 0) {
refresh_cmd_timeout();
current_position[Z_AXIS] += float((int)encoderPosition) * 0.05;
current_position[Z_AXIS] += float((int)encoderPosition) * MBL_Z_STEP;
if (min_software_endstops && current_position[Z_AXIS] < Z_MIN_POS) current_position[Z_AXIS] = Z_MIN_POS;
if (max_software_endstops && current_position[Z_AXIS] > Z_MAX_POS) current_position[Z_AXIS] = Z_MAX_POS;
encoderPosition = 0;
plan_buffer_line(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS], current_position[E_AXIS], manual_feedrate[Z_AXIS]/60, active_extruder);
lcdDrawUpdate = 1;
}
if (lcdDrawUpdate) lcd_implementation_drawedit(PSTR("Z"), ftostr32(current_position[Z_AXIS]));
if (lcdDrawUpdate) lcd_implementation_drawedit(PSTR("Z"), ftostr43(current_position[Z_AXIS]));
static bool debounce_click = false;
if (LCD_CLICKED) {
if (!debounce_click) {