Demo and test multiple PID defaults (#19413)

This commit is contained in:
Jason Smith 2020-09-17 01:06:01 -07:00 committed by Scott Lahteine
parent 07f13c28ee
commit 68c98811a1
2 changed files with 15 additions and 19 deletions

View File

@ -486,24 +486,17 @@
//#define PID_AUTOTUNE_MENU // Add PID auto-tuning to the "Advanced Settings" menu. (~250 bytes of PROGMEM)
//#define PID_PARAMS_PER_HOTEND // Uses separate PID parameters for each extruder (useful for mismatched extruders)
// Set/get with gcode: M301 E[extruder number, 0-2]
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
// Ultimaker
#define DEFAULT_Kp 22.2
#if ENABLED(PID_PARAMS_PER_HOTEND)
// Specify between 1 and HOTENDS values per array.
// If fewer than EXTRUDER values are provided, the last element will be repeated.
#define DEFAULT_Kp_LIST { 22.20, 20.0 }
#define DEFAULT_Ki_LIST { 1.08, 1.0 }
#define DEFAULT_Kd_LIST { 114.00, 112.0 }
#else
#define DEFAULT_Kp 22.20
#define DEFAULT_Ki 1.08
#define DEFAULT_Kd 114
// MakerGear
//#define DEFAULT_Kp 7.0
//#define DEFAULT_Ki 0.1
//#define DEFAULT_Kd 12
// Mendel Parts V9 on 12V
//#define DEFAULT_Kp 63.0
//#define DEFAULT_Ki 2.25
//#define DEFAULT_Kd 440
#define DEFAULT_Kd 114.00
#endif
#endif // PIDTEMP
//===========================================================================

View File

@ -36,7 +36,10 @@ opt_set TEMP_SENSOR_3 1
opt_set TEMP_SENSOR_4 1
opt_set TEMP_SENSOR_5 1
opt_set NUM_Z_STEPPER_DRIVERS 3
opt_enable TOOLCHANGE_FILAMENT_SWAP TOOLCHANGE_MIGRATION_FEATURE TOOLCHANGE_FS_INIT_BEFORE_SWAP TOOLCHANGE_FS_PRIME_FIRST_USED
opt_set DEFAULT_Kp_LIST "{ 22.2, 20.0, 21.0, 19.0, 18.0, 17.0 }"
opt_set DEFAULT_Ki_LIST "{ 1.08 }"
opt_set DEFAULT_Kd_LIST "{ 114.0, 112.0, 110.0, 108.0 }"
opt_enable TOOLCHANGE_FILAMENT_SWAP TOOLCHANGE_MIGRATION_FEATURE TOOLCHANGE_FS_INIT_BEFORE_SWAP TOOLCHANGE_FS_PRIME_FIRST_USED PID_PARAMS_PER_HOTEND
exec_test $1 $2 "BigTreeTech GTR 6 Extruders Triple Z"
# clean up