Fixed AUTOTEMP (M109 S215 B260 F1 starts autotemp)
Changed SLOWDOWN. IF this does not work ok OLD_SLOWDOWN is the old algo.
This commit is contained in:
@ -41,8 +41,8 @@
|
||||
// the target temperature is set to mintemp+factor*se[steps/sec] and limited by mintemp and maxtemp
|
||||
// you exit the value by any M109 without F*
|
||||
// Also, if the temperature is set to a value <mintemp, it is not changed by autotemp.
|
||||
// on an ultimaker, some initial testing worked with M109 S215 T260 F0.1 in the start.gcode
|
||||
//#define AUTOTEMP
|
||||
// on an ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
#define AUTOTEMP
|
||||
#ifdef AUTOTEMP
|
||||
#define AUTOTEMP_OLDWEIGHT 0.98
|
||||
#endif
|
||||
@ -94,8 +94,8 @@
|
||||
#define DEFAULT_MINIMUMFEEDRATE 0.0 // minimum feedrate
|
||||
#define DEFAULT_MINTRAVELFEEDRATE 0.0
|
||||
|
||||
// minimum time in microseconds that a movement needs to take if the buffer is emptied. Increase this number if you see blobs while printing high speed & high detail. It will slowdown on the detailed stuff.
|
||||
#define DEFAULT_MINSEGMENTTIME 20000 // Obsolete delete this
|
||||
// minimum time in microseconds that a movement needs to take if the buffer is emptied.
|
||||
#define DEFAULT_MINSEGMENTTIME 20000
|
||||
|
||||
// If defined the movements slow down when the look ahead buffer is only half full
|
||||
#define SLOWDOWN
|
||||
@ -147,9 +147,6 @@
|
||||
|
||||
#endif // ADVANCE
|
||||
|
||||
// A debugging feature to compare calculated vs performed steps, to see if steps are lost by the software.
|
||||
//#define DEBUG_STEPS
|
||||
|
||||
// Arc interpretation settings:
|
||||
#define MM_PER_ARC_SEGMENT 1
|
||||
#define N_ARC_CORRECTION 25
|
||||
|
Reference in New Issue
Block a user