M141 Heated Chamber, Temperature rework (#12201)

This commit is contained in:
3dlabsio
2019-03-07 00:09:39 -08:00
committed by Scott Lahteine
parent 44571775bd
commit 645ca7af7a
196 changed files with 2183 additions and 676 deletions

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -550,6 +551,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 7
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -565,6 +566,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 20
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -556,6 +557,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 11
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -565,6 +566,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -378,6 +378,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -558,6 +559,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -555,6 +556,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 13
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -546,6 +547,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -116,6 +116,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 1 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 60
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 0
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -533,6 +534,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -385,6 +385,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 0
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -546,6 +547,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 0
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -533,6 +534,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -378,6 +378,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -544,6 +545,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -555,6 +556,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -386,6 +386,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -564,6 +565,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -555,6 +556,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -549,6 +550,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -549,6 +550,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -555,6 +556,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -379,6 +379,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 0
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -553,6 +554,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -526,6 +527,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -526,6 +527,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -535,6 +536,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -550,6 +551,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -422,6 +422,7 @@
#define TEMP_SENSOR_BED 1
#endif
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -597,6 +598,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -392,6 +392,7 @@
#endif
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -574,6 +575,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -386,6 +386,7 @@
#endif
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -554,6 +555,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -528,6 +529,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -528,6 +529,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -560,6 +561,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -552,6 +553,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -560,6 +561,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -560,6 +561,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -549,6 +550,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -382,6 +382,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1 // measured to be satisfactorily accurate on center of bed within +/- 1 degC.
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -557,6 +558,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -397,6 +397,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -565,6 +566,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -385,6 +385,7 @@
// The reasons are inconclusive so I leave at 1
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -553,6 +554,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 11
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -544,6 +545,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 0
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 0
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -378,6 +378,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -546,6 +547,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 5
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -378,6 +378,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -546,6 +547,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -112,6 +112,20 @@
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#endif
#if ENABLED(PIDTEMP)
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
// if Kc is chosen well, the additional required power due to increased melting should be compensated.

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1 // Sanguinololu v1.3 with 4.7kOhm pullup
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -377,6 +377,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -545,6 +546,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

View File

@ -380,6 +380,7 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_BED 1
#define TEMP_SENSOR_CHAMBER 0
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
// Dummy thermistor constant temperature readings, for use with 998 and 999
#define DUMMY_THERMISTOR_998_VALUE 25
@ -541,6 +542,7 @@
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
//===========================================================================
//============================= Mechanical Settings =========================

Some files were not shown because too many files have changed in this diff Show More